If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
NEW Series S3P Three-Phase Output to 10A 440 Vac Cage Clamp Connectors Part Number S3P44D10 S3P44R10 Description 10A, 440 Vac 10A, 440 Vac Part Number Explanation S3P 44 D 10 NOTES 1) Line Voltage (maximum): 44 = 440 Vac 2) Switch Type: D = Zero-cross turn-on; R = Random turn-on MECHANICAL SPECIFICATION 1.4 0.007 (35.6 0.2) 0.77 0.007 (19.6 0.2) FEATURES/BENEFITS * Industry-standard hockey-puck package * Spring connectors * Three relays in a single package * Zero-cross and random turn-on options * Common control for all three relays Plugs = .32 0.007 (8.2 0.2) .4 (10.3) .4 (10.3) = 1.02 (26) .55 (14) .30 (7.5) .35 (8.9) 1.87 0.003 (47.6 0.1) .71 (18) 1 2 3 4 5 6 0.35 (9) .30 (7.5) O4.7 0.1 87 1.02 (26) .71 (18) .43 (11) .20 (5) DESCRIPTION The Series S3P relays are made up of three separate relays controlled by a common DC voltage control. They are designed to control 10A AC loads such as resistors and small motors on a mains from 12 to 440 Vac, either single- or three-phase. They are well suited for applications requiring compact size and low cost. APPLICATIONS * Heaters * Motors * Lighting APPROVALS UL is pending. 0.05 (1.2) 1.14 0.02 (29 0.5) 1.59 .007 (40.5 0.2) 2.3 +0.01 (58.5 +0.3) 2.0 0.003 (5.1 0.1) .02 +0.007 (5 +0.2) 1.75 +0.007 (44.5 +0.2) WEIGHT: 3.527 oz. (100g) .22 0.007 (5.5 0.2) Figure 1 -- Series S3P; dimensions in inches (mm) INPUT (CONTROL) SPECIFICATION Min Control Range Input Current Range Must Turn-Off Voltage Input Resistance (Typical) Reverse Voltage 4 3 Max 30 90 0.8 330 30 Units Vdc mA V Ohms V BLOCK DIAGRAM 1 7 zero volt 2 3 zero volt 4 5 zero volt 8 6 Figure 2 -- Series S3P (c) 2003 TELEDYNE RELAYS (800) 284-7007 * www.teledynerelays.com S3P 1 S3P\022003\Q1 Series S3P OUTPUT (LOAD) SPECIFICATION Min Operating Range Peak Voltage Load Current Range (Non-Repetitive) On-State Voltage Drop Synchronizing Level S3P44D10 Off-State Leakage Current Turn-On Time S3P44R10 S3P44D10 Turn-Off Time Off-State dv/dt Maximum di/dt (Non-Repetitive) Operating Frequency I t for Match Fusing (<8.3ms) Junction-Case Thermal Resistance Junction-Ambient Thermal Resistance 2 SURGE CURRENT Unit Vrms Vpeak Arms Apeak V V mArms ms ms ms V/s A/s Hz AS C/W C/W 2 120 110 100 90 Max 440 850 10 120 1.6 10 0.3 0.1 8.3 8.3 500 20 440 72 2.1 11.2 12 .05 Overload Current (A) 80 70 60 50 40 30 20 10 0 1 10 100 1000 Maximum Surge Current Rating Number of Cycles Figure 3 -- Series S3P ENVIRONMENTAL SPECIFICATION Min Operating Temperature Storage Temperature Input-Output Isolation Output-Case Isolation -40 -40 4000 2500 Max 100 100 Unit C C Vrms Vrms 10 THERMAL CHARACTERISTICS 50 45 2 80 85 /W 0C W C/ 0 .2 /W 5C 0.5 /W C 5 0.7 C/W 1. 0.9 35 30 25 20 15 10 5 0 0 1 2 3 4 5 6 7 8 9 10 2. 6 C/ W NO HE A TSIN K (8C /W) 0 10 20 30 40 50 60 70 80 90 100 110 120 125 Load Current (Arms) Ambient Temperature (C) Figure 4 -- Current derating curves NOTES: 1. Electrical specifications at 25C unless otherwise specified. 2. An external MOV is recommended for transient voltage protection. 3. For additional/custom options, contact factory. S3P 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2003 TELEDYNE RELAYS S3P\022003\Q1 90C 4 C/ W Max Case Temperature (C) 40 C/ W 2 C/ W Power Dissipation (W) |
Price & Availability of S3P44R10 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |