|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS380C.doc version 1.0 19.04.2001 VI TELEFILTER Filter specification TFS 380C 1/5 Measurement Condition Ambient Temperature: Input Power Level: Source impedance: Load impedance: Terminating impedances: input: output: 23 0 50 50 C dBm 720 || -4.7pF 1000 || -4.1pF Characteristics Remark: Reference level for the relative attenuation arel is the minimum pass band attenuation amin. It is defined as the insertion loss ae. The nominal frequency fN is fixed to 380,0 MHz. The center frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss ae The given values for the insertion loss, the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data Insertion Loss (Reference level) Nominal Frequency 1 dB - Bandwidth Relative Attenuation fN 2,5 fN 3,0 fN 3,25 fN 3,5 fN 5,0 fN 20,0 fN 40,0 fN 60,0 MHz ... fN 3,0 MHz ... fN 3,25 MHz ... fN 3,5 MHz ... fN 5,0 MHz ... fN 20,0 MHz ... fN 40,0 MHz ... fN 60,0 MHz ... fN 100,0 ae = amin typ. Value 14,0 dB max. Limit 17 dB fN BW 4,25 MHz min. 380,0 MHz 4,0 MHz arel MHz MHz MHz MHz MHz MHz MHz MHz 5 20 35 38 48 53 60 65 dB dB dB dB dB dB dB dB min. min. min. min. min. min. min. min. 3 10 20 30 40 45 50 55 dB dB dB dB dB dB dB dB Pass Band Ripple fN 2,0 MHz Group delay ripple fN 2,0 MHz 0,4 dB max. 1 dB 65 ns max. 100 ns Operating Temperature Range - 0 C ... + 70 C Generated: Checked / approved: VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS380C.doc version 1.0 19.04.2001 VI TELEFILTER Construction and pin connection Filter specification TFS 380C 2/5 Datecode S 380 C N16 1 2 3 4 5 6 7 8 9 10 11 12 Datecode: L M N ... Ground Ground Output RF Return Output Ground Ground Ground Ground Input RF Return Input Ground Ground Year+week 1999 2000 2001 50 test circuit C3 Output C1 Input L1 10 4 L2 C2 9 SAW 3 C4 1,2,5,6,7,8,11,12 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS380C.doc version 1.0 19.04.2001 VI TELEFILTER Stability Characteristics: Filter specification TFS 380C 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing: Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) W Po Do E F : : : : : 16 4 1,5 0,3 0,1 + 0,5 EMBOSSED CARRIER TAPE Do Po P2 1,75 0,1 7,5 0,1 0,6 2 0,1 8 0,1 1,5 5,5 7,5 0,1 0,1 COVER TAPE Ct Bo E Ao F W G (min) : P2 : P1 : D1(min) : Ao : Bo Ct : : D1 G P1 13,5+/-0,1 W2 Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : 0,2 : 330 16,4 +2 22,4 50 C A N 13 + 0,5 W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the sprocket holes. VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS380C.doc version 1.0 19.04.2001 VI TELEFILTER Filter specification TFS 380C 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS380C.doc version 1.0 19.04.2001 VI TELEFILTER History Version Reason of Changes Filter specification TFS 380C 5/5 Name Date Filter specification 1.0 new generation, template: TFS380A + add stopband requirements+ smaller passband Steiner 11.04.2000 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS380C |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |