If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS249A.doc version 2.0 08.06.2001 VI TELEFILTER Measurement condition Ambient temperature TA: Input power level: Terminating impedance at fc: input: output: 23 C 0 dBm Filter Specification TFS 249A 1/5 1,15 k || -6,5 pF 1,05 k || -6,5 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 249A is the minimum of the pass band attenuation amin . It is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 249,6 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data Insertion loss (Reference level) Nominal frequency Centre frequency 1 dB Bandwidth 3 dB Bandwidth 30 dB Bandwidth 40 dB Bandwidth Passband ripple within 1,92 MHz fN fc ae typ. value 14,0 249,6 4,72 5,71 9,08 9,60 MHz MHz MHz MHz MHz 0,4 10 48 60 35 16 dB dB dB dB ns dB dB tolerance / limit max. 20,0 249,6 dB MHz min. max. min. 3,84 11,0 1,0 MHz MHz dB Relative attenuation arel fN fN 1,92 MHz ... fN 3,08 MHz fN 5,5 MHz fN 5,5 MHz fN 15 MHz fN 15 MHz fN 30 MHz Group delay ripple within Return loss: within 1,92 MHz 1,92 MHz max. min. min. min. max. min. 1,0 3,0 40,0 50,0 50,0 10,0 dB dB dB dB ns dB Operating temperature range Temperature coefficient of frequency ( Tcf ) *) Frequency inversion temperature To Storage temperature range *) fc(Hz) = Tcf(ppm/K) x (To - TA) x fTo (MHz) - 10 C ... + 80 C 0,032 32 ppm/ K C - 30 C ... + 85 C Generated: Checked/Approved: VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS249A.doc version 2.0 08.06.2001 VI TELEFILTER Construction and pin connection (All dimensions in mm) 8 9 10 6 5 4 Filter Specification TFS 249A 2/5 S 249A N23 1 3 Datecode 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Output OutputRF Return Ground Ground Ground Input Input RF Return 1 10 9 8 3 4 5 6 Datecode: L M N ... Year+week 1999 2000 2001 50 matching network: L1 9 Input 50 Ohm C1 10 1,2,3,6,7 8,11,12 4 L2 Output C2 5 50 Ohm SAW VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS249A.doc version 2.0 08.06.2001 VI TELEFILTER Stability Characteristics Filter Specification TFS 249A 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dimensions in mm) W Po Do E F G (min) : P2 P1 : : : : : : : 16 4 1,5 0,3 0,1 + 0,1 Ao F W Do Po P2 3000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE E 1,75 0,1 7,5 0,1 0,60 2 8 1,5 5,5 7,5 13,5 0,1 0,1 0,1 COVER TAPE CT Bo D1 0,10 0,10 P1 G D1(min) : Ao Bo CT : : : W2 Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 16,4 +2,0 22,4 50 C A 13 + 0,5/-0,2 N W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS249A.doc version 2.0 08.06.2001 VI TELEFILTER Air reflow temperature conditions Filter Specification TFS 249A 4/5 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS249A.doc version 2.0 08.06.2001 VI TELEFILTER History Version Reason of Changes Filter Specification TFS 249A 5/5 Name Date Development specification 1.0 - generated according to Hudson's specification Dr. Sabah 30.08.2000 1.1 1.2 - Changed: group delay ripple:100ns 50ns Changed: terminating impedance change the 40 dB bandwidth to max 11 MHz Dr. Sabah Steiner 07.09.2000 28.05.2001 Filter specification 2.0 final filter specification - typical values and terminating impedances added Steiner 08.06.2001 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information |
Price & Availability of TFS249A |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |