 Agilent HPMD-7904 FBAR Duplexer for US PCS Band
Data Sheet
Features * Miniature size: less than 2 mm high; 5.6 x 11.9 footprint * Rx Band: 1930-1990 MHz Typical performance: Rx noise blocking: 42dB Insertion loss: 2.2 dB typical 3.0 dB band edge * Tx Band: 1850-1910 MHz Typical performance: Tx interferer blocking: 54dB Insertion Loss: 1.8 dB typical 2.5 dB band edge Functional Block Diagram * 30 dBm Tx power handling
General Description The HPMD-7904 is a miniaturized duplexer designed for US PCS handset, designed using Agilent Technologies' Film Bulk Acoustic Resonator (FBAR) Technology. The HPMD-7904 features a very small size: it is less than 2 mm thick and has a footprint of only 5.6 x 11.9 mm2. The HPMD-7904 enhances the sensitivity and dynamic range of CDMA receivers, providing more than 50 dB attenuation of transmitted signal at the receiver input, and more than 40 dB rejection of the transmitgenerated noise in the receive band. Typical insertion loss in the Tx channel is only 1.8 dB, minimizing current drain from the power amplifier. Typical insertion loss in the Rx channel is 2.2 dB, improving receiver sensitivity. Agilent's thin-Film Bulk Acoustic Resonator (FBAR) technology makes possible high-Q filters at a fraction their usual size. The excellent power handling of the bulk-mode resonators supports the high output powers needed in PCS handsets, with virtually no added distortion.
Board Diagram
Tx
/4
Rx
1 3
2
Ant
Applications * Handsets or data terminals operating in the US PCS frequency band
port numbers are circled
HPMD-7904 Electrical Specifications, ZO = 50, TC[1] as indicated Symbol
fRX S23 Rx S23 Rx S23 Rx
Parameters
Receive Bandwidth Attenuation in Transmit Band (1850.6 - 1909.4 MHz) Typical Insertion Loss in Receive Band (1935-1985MHz) Insertion Loss at Edges of Receive Band (1930.6-1935 MHz and 1985-1989.4 MHZ) Ripple in Receive Band Return Loss in Receive Band Transmit Bandwidth Attenuation in Receive Band (1930.6 - 1935 MHz) Attenuation in Receive Band (1935- 1989.4 MHz) Insertion Loss in Transmit Band (1855- 1905 MHz) Insertion Loss at Edges of Transmit Band (1850.6-1855 MHz and 1905-1909.4 MHz) Ripple in Transmit Band Return Loss in Transmit Band Return Loss, Tx and Rx bands Tx-Rx Isolation, 1850.6 - 1909.4 MHz (Transmit Band) Tx-Rx Isolation, 1930.6 - 1935 MHz (Receive Band) Tx-Rx Isolation, 1935- 1989.4 MHz (Receive Band)
Units
MHz dB dB dB
+25C[1,3] Min Typ Max
1930.6 -- 50 -- -- 54 2.2 3.0 1989.4 -- 3.5 3.5
+85C[1,2,3] Min Typ Max
1930.6 -- 50 -- -- 52 2.2 3.0 1989.4 -- 3.8 3.8
-30C[1,2,3] Min Typ Max
1930.6 -- 50 -- -- 52 2.2 3.0 1989.4 -- 3.8 4.5
S23 S22 Rx fTX S31 Tx S31 Tx S31 Tx S31 Tx
dB dB MHz dB dB dB dB
-- 8.0
1.5 10
-- -- 1909.4 -- -- 3.0 3.0
-- 8.0
1.5 10
-- -- 1909.4 -- -- 3.5 3.8
-- 8.0
2.0 10
-- -- 1909.4 -- -- 3.5 3.6
1850.6 -- 40 40 -- -- 42 42 1.8 2.5
1850.6 -- 40 40 -- -- 42 42 1.8 3.0
1850.6 -- 37 40 -- -- 42 42 1.8 3.0
S31 S11 Tx S33 Ant S21 S21 S21
dB dB dB dB dB dB
-- 8.0 8.0 50 40 40
2.0 10 -- 54 42 42
-- -- -- -- -- --
-- 8.0 -- 50 40 40
3.0 10 -- 54 42 42
-- -- -- -- -- --
-- 8.0 -- 50 38 40
2.0 10 -- 54 42 42
-- -- -- -- -- --
Absolute Maximum Ratings[4] Parameter
Operating temperature[1] Storage temperature[1]
Unit
C C
Value
-30 to +85 -30 to +100
Notes: 1. TC is defined as case temperature, the temperature of the underside of the duplexer where it makes contact with the circuit board. 2. Specifications are given at operating temperature limits and room temperature. To estimate performance at some intermediate temperature, use linear interpolation. 3. Specifications are guaranteed over the given temperature range, with the input power to the Tx port equal to +30 dBm (or lower) over all Tx frequencies. The application of input power levels in excess of +30 dBm will not destroy the duplexer, but its performance may exceed the specification limits given above. 4. Operation in excess of any one of these conditions may result in permanent damage to the device.
2
The plots below provide typical performance obtained from samples of the HPMD-7904 duplexer.
In order to obtain the best performance from the HPMD-7904 duplexer, refer to Design Note D007, which is
available from your Agilent Technologies technical support or sales departments.
0
0
S31
INSERTION LOSS AND REJECTION (dB)
-10 -20 -30 -40 -50
INSERTION LOSS AND REJECTION (dB)
-1
-2
S31 S23
-3
S23
-60 -70 1.82
-4
1.84
1.86
1.88
1.90
1.92
1.94
1.96
1.98
2.00
2.02
-5 1.82
1.84
1.86
1.88
1.90
1.92
1.94
1.96
1.98
2.00
2.02
FREQUENCY (GHz)
FREQUENCY (GHz)
Figure 1. Tx and Rx Port Insertion Loss (typical).
Figure 2. Insertion Loss Detail (typical).
0
0
-5
-5
RETURN LOSS (dB)
RETURN LOSS (dB)
-10
-10
S11
-15
S22
S33
-15
-20 1.82
1.84
1.86
1.88
1.90
1.92
1.94
1.96
1.98
2.00
2.02
-20 1.82
1.84
1.86
1.88
1.90
1.92
1.94
1.96
1.98
2.00
2.02
FREQUENCY (GHz)
FREQUENCY (GHz)
Figure 3. Tx and Rx Port Return Loss (typical).
Figure 4. Ant Port Return Loss (typical).
freq (1.850 GHz to 1.910 GHz)
freq (1.930 GHz to 1.990 GHz)
Figure 5. S11, Tx Port Impedance (typical).
Figure 6. S22, Rx Port Impedance (typical).
3
-20 -30
A
ISOLATION (dB)
-40 -50 -60 -70 -80 1.82
S21
B
A: freq (1.850 GHz to 1.910 GHz) B: freq (1.930 GHz to 1.990 GHz)
1.84
1.86
1.88
1.90
1.92
1.94
1.96
1.98
2.00
2.02
FREQUENCY (GHz)
Figure 7. S33, Ant Port Impedance.
Figure 8. S21, Isolation (typical).
0 -5 -10
S31
-10 -15 -20
RETURN LOSS (dB)
ISOLATION (dB)
-15 -20
-25 -30 -35 -40 -45
S23
-25 -30 -35 -40 -45 -50 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 FREQUENCY (GHz)
S21
-50 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 FREQUENCY (GHz)
Figure 9. Wideband Insertion Loss (typical).
Figure 10. Wideband Isolation (typical).
4
Note that the specifications given on page 2 are guaranteed when the duplexer is mounted on a ground surface with a hole pattern like that one shown in Figure 11. See Design Note D007,
which is available from your Agilent Technologies technical support or sales departments. Note that it is important that proper heat sinking be provided
in order to remove the heat generated in the Tx filter by the handset's power amplifier. Failure to do so may result in excessive losses, especially at the top end of the Tx band.
Tx input
Rx output
Ant input/output Duplexer outline shown in dashed line
0.4 mm diameter plated through holes typical spacing is 0.77 to 0.9 mm
Figure 11. Mounting (grounding) Pattern.
5.625 0.05 4.763 4.256 3.494 2.985 4.389 3.881 3.119 2.611
Port 1 Tx
Port 2 Rx
Port 3 Ant 1.016 0.508 0 via hole, 0.28 dia 3 places
0 0.508 1.016
3.361 3.869
4.631 5.139
Notes: View of the duplexer underside, seen from the top. All dimensions in millimeters. Pin assignments are as shown above. Maximum duplexer height is 1.9 mm.
Figure 12. Outline Drawing.
5
10.859 11.367 11.875 0.05
0.0300.05
Note 2 4.00 0.10
Note 6 2.00 0.10
1.50 0.10 1.75 0.1 Note 6 11.50 0.10
12.20 Note 4
24.00 0.30
2.25 Note 5
6.60 Note 4
12.00 0.10
1.50
Notes: 1. All dimensions in mm. 2. 10 sprocket hole pitch accumulative tolerance 0.10 mm 3. Camber not exceed 1 mm in 250 mm 4. Pocket dimensions measured on a plane 0.3 mm above the bottom of the pocket. 5. Pocket depth measured from a plane on the inside bottom of the pocket to the top surface of the carrier. 6. Pocket position on relative to sprocket hole measure as true position of pocket, not the pocket hole.
Figure 13. Tape Drawing.
R 6.26"
+1.00" -0.50"
120.00 0.50
R 5.27"
+1.00" -0.50"
R 0.20"
+1.00" R 5:49" -0.50"
2.00 0.50 +0.40" 13.00" -0"
21.000.80
CONVEX = 0.5mm
13.00" -0.20"
+0.50"
100.00
+2.00 -0
0.22" +1.00" R 6.26" -0.50" +1.00" -0.50" 2.20
R 2.00"
Notes: 1. All dimensions in mm, unless otherwise noted. 2. Material: polystyrene 3. Surface resistivity: 1x109 ohm-mm2
Figure 14. Reel Drawing.
R 2.00"
+1.00" -0.50"
6
REEL
User Feed Direction
CARRIER TAPE USER FEED DIRECTION COVER TAPE
xx DO xx 1x
xx DO xx 1x
xx DO xx 1x
xx DO xx 1x
xx DO xx 1x
xx DO xx 1x
xx DO xx 1x
xx DO xx 1x
Top View Empty Pocket/Cavity Leader: 100 pocket - 1 Meter Trailer: 100 pocket - 1 Meter
End View
Figure 15. Device Orientation.
Solder Recommendations The HPMD-7904 FBAR duplexer (and its variants) is an assembly consisting of two LCC ceramic packages, containing the Tx and Rx filters, mounted to a small circuit board. Both packages on the circuit board are mounted in place using Sn96.5/Ag3.5 solder (shaded in Table 1).
The recommended solder profile for the FBAR duplexer is shown in Figure 16. Guidelines and a typical profile are both shown. This typical profile was tested on ten samples of the duplexer, each of which was subjected to the profile six times without effect upon the mechanical or electrical characteristics of the device.
Solder temperatures and times in excess of those given in the guidelines of Table 1 may result in damage to the duplexer or changes in its characteristics.
Table 1. Solder Compositions Alloy type
Sn42Bi58 Sn43Pb43Bi14 Sn63Pb37 Sn60Pb40 Sn91/Zn9 Sn96.2Ag2.5Cu0.8Sb0.5 Sn95.8Ag3.5Cu0.7 Sn96.5Ag3.5 Sn100 Sn95Sb5 Sn97Cu3
Melting temp. (oC)
138 144 - 163 183 186 199 216 217 221 232 235 240
Recommended working temperature (oC)
160 - 180 165 - 185 200 - 240 200 - 240 200 - 240 235 - 255 235 - 255 240 - 260 260 - 280 260 - 280 260 - 300
Comments
Lead free Contains lead - some customers prohibit it. Contains lead - some customers prohibit it. Contains lead - some customers prohibit it. May have oxidation problems Popular lead free composition Other alloy ratios are available Used in the assembly of duplexers Too hot - will melt the duplexer Too hot - will melt the duplexer Too hot - will melt the duplexer
7
10 to 20 sec. 250 217C 200 235C 5C
TEMPERATURE, C
125C 25C 150
60 to 120 sec.
-6C/sec. max 3C/sec. max 100
120 sec. max. 50
Guidelines Tested profile
0 0 100 200 300 400 500 600
TIME, seconds
Figure 16. Recommended Solder Profile.
www.agilent.com/semiconductors
For product information and a complete list of distributors, please go to our web site. For technical assistance call: Americas/Canada: +1 (800) 235-0312 or (408) 654-8675 Europe: +49 (0) 6441 92460 China: 10800 650 0017 Hong Kong: (+65) 6271 2451 India, Australia, New Zealand: (+65) 6271 2394 Japan: (+81 3) 3335-8152(Domestic/International), or 0120-61-1280(Domestic Only) Korea: (+65) 6271 2194 Malaysia, Singapore: (+65) 6271 2054 Taiwan: (+65) 6271 2654 Data subject to change. Copyright (c) 2002 Agilent Technologies, Inc. May 30, 2002 5988-6610EN


▲Up To Search▲   

 
Price & Availability of HPMD-7904

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X