 TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
* * * * * * * * * * * *
Increased Logic Power - Up to 22 Inputs and 10 Outputs Increased Product Terms - Average of 12 Per Output Variable Product Term Distribution Allows More Complex Functions to Be Implemented Each Output Is User Programmable for Registered or Combinational Operation, Polarity, and Output Enable Control Power-Up Clear on Registered Outputs TTL-Level Preload for Improved Testability Extra Terms Provide Logical Synchronous Set and Asynchronous Reset Capability Fast Programming, High Programming Yield, and Unsurpassed Reliability Ensured Using Ti-W Fuses AC and DC Testing Done at the Factory Utilizing Special Designed-In Test Features JEDEC Approved Revolutionary Power and Ground Pinout for 28-Pin Chip Carrier Reduces Cross Talk and Ground Bounce JEDEC File Compatibility Allows Previous '22V10 Designs to be Programmed Into the TIBPAL22V10-5C Without Modifications
I/O/Q GND I/O/Q VCC I/O/Q GND I/O/Q
5 6 7 8 9
I/O/Q I I CLK/I I I I
4 3 2 1 28 27 26 25 24 23 22 21 10 20 11 19 12 13 14 15 16 17 18
High-Performance Operation: fmax (External Feedback) . . . 117 MHz Propagation Delay . . . 5 ns Max
FN PACKAGE (TOP VIEW)
I/O/Q GND I/O/Q VCC I/O/Q GND I/O/Q
description
The TIBPAL22V10-5C is a programmable array logic device featuring high speed and functional equivalency when compared to presently available devices. The TIBPAL22V10-5C is implemented with the familiar sum-of-products (AND-OR) logic structure featuring programmable output logic macrocells. These IMPACT-XLTM circuits combine the latest Advanced Low-Power Schottky technology with proven titaniumtungsten fuses to provide reliable, high-performance substitutes for conventional TTL logic. This device contains up to 22 inputs and 10 outputs. It incorporates the unique capability of defining and programming the architecture of each output on an individual basis. Outputs can be registered or nonregistered and inverting or noninverting as shown in the output logic macrocell diagram. The ten potential outputs are enabled through the use of individual product terms. Further advantages can be seen in the introduction of variable product term distribution. This technique allocates from 8 to 16 logical product terms to each output for an average of 12 product terms per output. This variable allocation of terms allows far more complex functions to be implemented than in previously available devices.
This device is covered by U.S. Patent 4,410,987. IMPACT-XL is a trademark of Texas Instruments Incorporated.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
I I I I I I I/O/Q
Copyright (c) 1993, Texas Instruments Incorporated
1
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
description (continued)
Circuit design is enhanced by the addition of a synchronous set and an asynchronous reset product term. These functions are common to all registers. When the synchronous set product term is a logic 1, the output registers are loaded with a logic 1 on the next low-to-high clock transition. When the asynchronous reset product term is a logic 1, the output registers are loaded with a logic 0. The output logic level after set or reset depends on the polarity selected during programming. Output registers can be preloaded to any desired state during testing. Preloading permits full logical verification during product testing. With features such as programmable output logic macrocells and variable product term distribution, the TIBPAL22V10-5C offers quick design and development of custom LSI functions with complexities of 500 to 800 equivalent gates. Since each of the ten output pins can be individually configured as inputs on either a temporary or permanent basis, functions requiring up to 21 inputs and a single output or down to 12 inputs and 10 outputs are possible. A power-up clear function is supplied that forces all registered outputs to a predetermined state after power is applied to the device. Registered outputs selected as active-low power up with their outputs high. Registered outputs selected as active-high power up with their outputs low. A single security fuse is provided on each device to discourage unauthorized copying of fuse patterns. Once blown, the verification circuitry is disabled and all other fuses will verify as open. The TIBPAL22V10-5C is characterized for operation from 0C to 75C.
2
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
functional block diagram (positive logic)
C1 & 44 x 132 8 Set Reset 1 1S R Output Logic Macrocell
I/O/Q EN I/O/Q
10 CLK/I 22 EN I/O/Q 14 EN I/O/Q 16 EN I/O/Q 16 I 11 10 22 EN I/O/Q 14 EN I/O/Q 12 EN I/O/Q 10 EN I/O/Q 8 EN I/O/Q 10 10 denotes fused inputs EN 10
12
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
3
4
POST OFFICE BOX 655303
logic diagram (positive logic)
Increment
0 4 8 12 16 20 24 28 32 36 40
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
CLK/I I I
1 2 3 First Fuse Numbers 4
Macrocell
28 27 26 0
I I
I Asynchronous Reset (to all registers)
I/O/Q
P = 5808 R = 5809 440
396
Macrocell
25
I/O/Q
880 P = 5810 R = 5811 924
I/O/Q
5
Macrocell
* DALLAS, TEXAS 75265
P = 5812 R = 5813
1452
1496
Macrocell
23
I/O/Q
2112 P = 5814 R = 5815
2156
I/O/Q
7
Macrocell
2860 P = 5816 R = 5817
2904
Macrocell
21
I/O/Q
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
3608 P = 5818 R = 5819 3652
I/O/Q
9
Macrocell
POST OFFICE BOX 655303
4268 P = 5820 R = 5821 4312
Macrocell
19
I/O/Q
* DALLAS, TEXAS 75265
5
4840 P = 5822 R = 5823 4884
I/O/Q
11
Macrocell
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
5324 P = 5824 R = 5825 5368
Macrocell
18
I/O/Q
5720
Synchronous Set (to all registers) 12 I 13 I 14 I
P = 5826 R = 5827 5764
17 16 15
I I I
Fuse number = First fuse number + Increment Inside each MACROCELL the "P" fuse is the polarity fuse and the "R" fuse is the register fuse.
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
output logic macrocell diagram
Output Logic Macrocell MUX 2 AR R I=0 1D C1 SS From Clock Buffer MUX 1 1 G1 1S 3 0 1 1 0 S0 G 0 3
S1
AR = asynchronous reset SS = synchronous set
6
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
R 1D C1 1S S1 = 0 S0 = 0
R 1D C1 1S S1 = 0 S0 = 1
REGISTER FEEDBACK, REGISTERED, ACTIVE-LOW OUTPUT
REGISTER FEEDBACK, REGISTERED, ACTIVE-HIGH OUTPUT
S1 = 1 S0 = 0
S1 = 1 S0 = 1
I/O FEEDBACK, COMBINATIONAL, ACTIVE-LOW OUTPUT
I/O FEEDBACK, COMBINATIONAL, ACTIVE-HIGH OUTPUT
MACROCELL FEEDBACK AND OUTPUT FUNCTION TABLE FUSE SELECT S1 S0 0 0 1 1 0 1 0 1 FEEDBACK AND OUTPUT CONFIGURATION Register feedback Register feedback I/O feedback I/O feedback Registered Registered Combinational Combinational Active low Active high Active low Active high
0 = unblown fuse, 1 = blown fuse S1 and S0 are select-function fuses as shown in the output logic macrocell diagram.
Figure 1. Resultant Macrocell Feedback and Output Logic After Programming
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
7
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage range (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -1.2 V to VCC +0.5 V Voltage range applied to disabled output (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . - 0.5 V to VCC +0.5 V Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0C to 75C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65C to 150C
NOTE 1: These ratings apply except for programming pins during a programming cycle or during a preload cycle.
recommended operating conditions
MIN VCC VIH VIL IOH IOL tw Supply voltage High-level input voltage (see Note 2) Low-level input voltage (see Note 2) High-level output current Low-level output current Pulse duration Clock high or low Asynchronous reset high or low Input Feedback tsu Setup time before clock Synchronous preset (active) Synchronous preset (inactive) Asynchronous reset (inactive) th TA Hold time, input, set, or feedback after clock Operating free-air temperature 3.5 5 4.5 4.5 7 7 6 0 0 75 ns C ns 4.75 2 NOM 5 MAX 5.25 5.5 0.8 - 3.2 16 UNIT V V V mA mA ns
NOTE 2: These are absolute voltage levels with respect to the ground terminal of the device and includes all overshoots due to system and/or tester noise. Testing these parameters should not be attempted without suitable equipment.
8
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
electrical characteristics over recommended operating free-air temperature range
PARAMETER VIK VOH VOL IOZH IOZL II IIH IIL IOS ICC Ci I CLK CLK All others VCC = 4.75 V, VCC = 4.75 V, VCC = 4.75 V, VCC = 5.25 V, VCC = 5.25 V, VCC = 5.25 V, VCC = 5.25 V, VCC = 5.25 V, VCC = 5.25 V, VCC = 5.25 V, f = 1 MHz, TEST CONDITIONS II = - 18 mA IOH = - 3.2 mA IOL = 16 mA VO = 2.7 V VO = 0.4 V VI = 5.5 V VI = 2.7 V VI = 0.4 V VO = 0.5 V VI = GND, VI = 2 V - 30 Outputs open 7 8 MIN 2.4 0.35 0.5 0.1 - 0.1 1 25 - 0.3 - 0.1 - 130 210 TYP MAX - 1.2 UNIT V V V mA mA mA A mA mA mA pF
Co f = 1 MHz, VO = 2 V 10 pF All typical values are at VCC = 5 V, TA = 25C. I/O leakage is the worst case of IOZL and IIL or IOZH and IIH, respectively. Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second. VO is set at 0.5 V to avoid test problems caused by test equipment ground degradation.
switching characteristics over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER fmax tpd tpd tpd tpd# ten tdis fmax (without feedback) = FROM (INPUT) TO (OUTPUT) TEST CONDITIONS MIN 143 133 117 R1 = 300 , R2 = 300 , See Figure 4 0.5 1 5 10 4 3 6.5 6 ns ns ns ns ns ns Q Q Feedback I/O, Q I/O, Q 1 MHz MAX UNIT
Without feedback With internal feedback (counter configuration) With external feedback I, I/O I, I/O (reset) CLK CLK I, I/O I, I/O t w(low) I/O
fmax (with internal feedback) = fmax (with external feedback) =
) tw(high) 1 t su ) t (CLK to feedback) pd
t su
1 (CLK to Q) pd # This parameter is calculated from the measured fmax with internal feedback in the counter configuration. t
)
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
9
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
preload procedure for registered outputs (see Note 3)
The output registers can be preloaded to any desired state during device testing. This permits any state to be tested without having to step through the entire state-machine sequence. Each register is preloaded individually by following the steps given below: Step 1. Step 2. Step 3. Step 4. With VCC at 5 V and pin 1 at VIL, raise pin 14 to VIHH. Apply either VIL or VIH to the output corresponding to the register to be preloaded. Pulse pin 1, clocking in preload data. Remove output voltage, then lower pin 14 to VIL. Preload can be verified by observing the voltage level at the output pin.
VIHH Pin 14 tsu td Pin 1 tw VIH VIL VIH Registered I/O Input VIL Output VOL VOH td VIL
Figure 2. Preload Waveforms
NOTE 3: td = tsu = tw = 100 ns to 1000 ns. VIHH = 10.25 V to 10.75 V.
10
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
power-up reset
Following power up, all registers are reset to zero. The output level depends on the polarity selected during programming. This feature provides extra flexibility to the system designer and is especially valuable in simplifying state-machine initialization. To ensure a valid power-up reset, it is important that the rise of VCC be monotonic. Following power-up reset, a low-to-high clock transition must not occur until all applicable input and feedback setup times are met.
VCC 4V tpd (600 ns typ, 1000 ns MAX) Active High Registered Output VOH State Unknown 1.5 V VOL Active Low Registered Output VOH State Unknown 1.5 V VOL tsu VIH CLK 1.5 V tw This is the power-up reset time and applies to registered outputs only. The values shown are from characterization data. This is the setup time for input or feedback. 1.5 V VIL 5V
Figure 3. Power-Up Reset Waveforms
programming information
Texas Instruments programmable logic devices can be programmed using widely available software and inexpensive device programmers. Complete programming specifications, algorithms, and the latest information on hardware, software, and firmware are available upon request. Information on programmers capable of programming Texas Instruments programmable logic is also available, upon request, from the nearest TI field sales office, local authorized TI distributor, or by calling Texas Instruments at (214) 997-5666.
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
11
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
PARAMETER MEASUREMENT INFORMATION
5V
S1 R1 From Output Under Test CL (see Note A) R2 Test Point
LOAD CIRCUIT FOR 3-STATE OUTPUTS Timing Input tsu Data Input 1.5 V 3V 1.5 V 0 th 3V 1.5 V 0 (see Note B) VOLTAGE WAVEFORMS SETUP AND HOLD TIMES 3V Input tpd In-Phase Output tpd Out-of-Phase Output (see Note D) 1.5 V 1.5 V 1.5 V 1.5 V 0 tpd VOH 1.5 V VOL tpd VOH 1.5 V VOL Output Control (low-level enabling) ten 1.5 V 1.5 V 0 (see Note B) tdis Low-Level Pulse 3V 1.5 V 1.5 V 0 (see Note B) tw High-Level Pulse 3V 1.5 V 1.5 V 0
VOLTAGE WAVEFORMS PULSE DURATIONS
3V
2.5 V
Waveform 1 S1 Closed (see Note C) ten Waveform 2 S1 Open (see Note C) 1.5 V VOL tdis VOH 1.5 V
VOL + 0.5 V
VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES
0V
VOH - 0.5 V
VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS NOTES: A. CL includes probe and jig capacitance and is 50 pF for tpd and ten, 5 pF for tdis. B. All input pulses have the following characteristics: PRR 1 MHz, tr = tf = 2 ns, duty cycle = 50%. C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. D. When measuring propagation delay times of 3-state outputs, switch S1 is closed. E. Equivalent loads may be used for testing.
Figure 4. Load Circuit and Voltage Waveforms
12
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
TYPICAL CHARACTERISTICS
SUPPLY CURRENT vs FREE - AIR TEMPERATURE
220 210 200 VCC = 5.25 V 190 180 VCC = 5 V 170 160 VCC = 4.75 V 150 140 0 25 50 TA - Free - Air Temperature - C 75 Propagation Delay Time - ns I CC - Supply Current - mA 7 6 5 4 3 2 1 TA = 25C CL = 50 pF R1 = 300 R2 = 300 10 Outputs Switching 5 VCC - Supply Voltage - V 5.25 tPLH (I, I/O to O, I/O) tPHL (I, I/O to O, I/O) tPLH (CLK to Q) tPHL (CLK to Q)
PROPAGATION DELAY TIME vs SUPPLY VOLTAGE
0 4.75
Figure 5
Figure 6
PROPAGATION DELAY TIME vs FREE - AIR TEMPERATURE
7 6 Propagation Delay Time - ns 5 4 3 2 1 VCC = 5 V CL = 50 pF R1 = 300 R2 = 300 10 Outputs Switching 0 25 50 TA - Free - Air Temperature - C 75 pd - Propagation Delay Time - ns 16 14 12 10
PROPAGATION DELAY TIME vs LOAD CAPACITANCE
VCC = 5 V TA = 25C R1 = 300 R2 = 300 1 Output Switching
tPHL (I, I/O to O, I/O) tPLH (I, I/O to O, I/O) tPLH (CLK to Q) tPHL (CLK to Q)
tpd (I, I/O to O, I/O) 8 tpd (CLK to Q) 6 4 2 0 0 100 500 600 200 300 400 CL - Load Capacitance - pF 700
0
Figure 7
t
Figure 8
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
13
TIBPAL22V10-5C HIGH-PERFORMANCE IMPACT-XLTM PROGRAMMABLE ARRAY LOGIC CIRCUIT
SRPS028A - MAY 1992 - REVISED OCTOBER 1993
TYPICAL CHARACTERISTICS
WORST-CASE PROPAGATION DELAY TIME vs NUMBER OF OUTPUTS SWITCHING
7 VCC = 5 V TA = 0C CL = 50 pF R1 = 300 R2 = 300 = tPHL (I, I/O to O, I/O) = tPLH (I, I/O to O, I/O) = tPLH (CLK to Q) = tPHL (CLK to Q)
6 Propagation Delay Time - ns
5
4
3
2
1 1 2 6 7 6 3 4 5 Number of Outputs Switching 7 10
Figure 9
POWER DISSIPATION vs FREQUENCY 10 - BIT COUNTER MODE
1200 VCC = 5 V P - Power Dissipation - mW D
1100 TA = 75C 1000
900
TA = 0C
TA = 25C
800 1 2 4 10 20 40 100 f - Frequency - MHz
Figure 10
14
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
TI Worldwide Sales Offices
ALABAMA: Huntsville: 4960 Corporate Drive, Suite 150, Huntsville, AL 35805, (205) 837-7530. ARIZONA: Phoenix: 8825 N. 23rd Avenue, Suite 100, Phoenix, AZ 85021, (602) 995-1007. CALIFORNIA: Irvine: 1920 Main Street, Suite 900, Irvine, CA 92714, (714) 660-1200; San Diego: 5625 Ruffin Road, Suite 100, San Diego, CA 92123, (619) 278-9600; Santa Clara: 5353 Betsy Ross Drive, Santa Clara, CA 95054, (408) 980-9000; Woodland Hills: 21550 Oxnard Street, Suite 700, Woodland Hills, CA 91367, (818) 704-8100. COLORADO: Aurora: 1400 S. Potomac Street, Suite 101, Aurora, CO 80012, (303) 368-8000. CONNECTICUT: Wallingford: 9 Barnes Industrial Park So., Wallingford, CT 06492, (203) 269-0074. FLORIDA: Altamonte Springs: 370 S. North Lake Boulevard, Suite 1008, Altamonte Springs, FL 32701, (407) 260-2116; Fort Lauderdale: 2950 N.W. 62nd Street, Suite 100, Fort Lauderdale, FL 33309, (305) 973-8502; Tampa: 4803 George Road, Suite 390, Tampa, FL 33634-6234, (813) 885-7588. GEORGIA: Norcross: 5515 Spalding Drive, Norcross, GA 30092-2560, (404) 662-7967. ILLINOIS: Arlington Heights: 515 West Algonquin, Arlington Heights, IL 60005, (708) 640-6925. INDIANA: Carmel: 550 Congressional Drive, Suite 100, Carmel, IN 46032, (317) 573-6400; Fort Wayne: 103 Airport North Office Park, Fort Wayne, IN 46825, (219) 489-4697. KANSAS: Overland Park: 7300 College Boulevard, Lighton Plaza, Suite 150, Overland Park, KS 66210, (913) 451-4511. MARYLAND: Columbia: 8815 Centre Park Drive, Suite 100, Columbia, MD 21045, (410) 964-2003. MASSACHUSETTS: Waltham: Bay Colony Corporate Center 950 Winter Street, Suite 2800, Waltham, MA 02154, (617) 895-9100. MICHIGAN: Farmington Hills: 33737 W. 12 Mile Road, Farmington Hills, MI 48018, (313) 553-1581. MINNESOTA: Eden Prairie: 11000 W. 78th Street, Suite 100, Eden Prairie, MN 55344, (612) 828-9300. MISSOURI: St. Louis: 12412 Powerscourt Drive, Suite 125, St. Louis, MO 63131, (314) 821-8400. NEW JERSEY: Iselin: Metropolitan Corporate Plaza, 485 Bldg E. U.S. 1 South, Iselin, NJ 08830, (908) 750-1050. NEW MEXICO: Albuquerque: 2709 J. Pan American Freeway, NE, Albuquerque, NM 87101, (505) 345-2555. NEW YORK: East Syracuse: 6365 Collamer Drive, East Syracuse, NY 13057, (315) 463-9291; Fishkill: 300 Westage Business Center, Suite 140, Fishkill, NY 12524, (914) 897-2900; Melville: 48 South Service Road, Suite 100, Melville, NY 11747, (516) 454-6601; Pittsford: 2851 Clover Street, Pittsford, NY 14534, (716) 385-6770. NORTH CAROLINA: Charlotte: 8 Woodlawn Green, Suite 100, Charlotte, NC 28217, (704) 527-0930; Raleigh: 2809 Highwoods Boulevard, Suite 100, Raleigh, NC 27625, (919) 876-2725. OHIO: Beachwood: 23775 Commerce Park Road, Beachwood, OH 44122-5875, (216) 765-7258; Beavercreek: 4200 Colonel Glenn Highway, Suite 600, Beavercreek, OH 45431, (513) 427-6200. OREGON: Beaverton: 6700 S.W. 105th Street, Suite 110, Beaverton, OR 97005, (503) 643-6758. PENNSYLVANIA: Blue Bell: 670 Sentry Parkway, Suite 200, Blue Bell, PA 19422, (215) 825-9500. PUERTO RICO: Hato Rey: 615 Mercantil Plaza Building, Suite 505, Hato Rey, PR 00919, (809) 753-8700. TEXAS: Austin: 12501 Research Boulevard, Austin, TX 78759, (512) 250-6769; Dallas: 7839 Churchill Way, Dallas, TX 75251, (214) 917-1264; Houston: 9301 Southwest Freeway, Commerce Park, Suite 360, Houston, TX 77074, (713) 778-6592; Midland: FM 1788 & I-20, Midland, TX 79711-0448, (915) 561-7137.
UTAH: Salt Lake City: 2180 South 1300 East, Suite 335, Salt Lake City, UT 54106, (801) 466-8972. WISCONSIN: Waukesha: 20825 Swenson Drive, Suite 900, Waukesha WI 53186, (414) 798-1001. CANADA: Nepean: 301 Moodie Drive, Suite 102, Mallorn Centre, Nepean, Ontario, Canada K2H 9C4, (613) 726-1970; Richmond Hill: 280 Centre Street East, Richmond Hill, Ontario, Canada L4C 1B1, (416) 884-9181; St. Laurent: 9460 Trans Canada Highway, St. Laurent, Quebec, Canada H4S 1R7, (514) 335-8392.
AUSTRALIA (& NEW ZEALAND): Texas Instruments Australia Ltd., 6-10 Talavera Road, North Ryde (Sydney), New South Wales, Australia 2113, 2-878-9000; 14th Floor, 380 Street, Kilda Road, Melbourne, Victoria, Australia 3000, 3-696-1211. BELGIUM: Texas Instruments Belgium S.A./N.V., Avenue Jules Bordetlaan 11, 1140 Brussels, Belgium, (02) 242 30 80. BRAZIL: Texas Instruments Electronicos do Brasil Ltda., Av. Eng. Luiz Carlos Berrini 1461-11o. andar, 04571, Sao Paulo, SP, Brazil, 11-535-5133. DENMARK: Texas Instruments A/S, Borupvang 2D, DK-2750 Ballerup, Denmark, (44) 68 74 00. FINLAND: Texas Instruments OY, Ahertajantle 3, P.O. Box 86, 02321 Espoo, Finland, (0) 802 6517. FRANCE: Texas Instruments France, 8-10 Avenue Morane-Saulnier, B.P. 67, 78141 Velizy-Villacoublay Cedex, France, (1) 30 70 1003. GERMANY: Texas Instruments Deutschland GmbH., Haggertystrae 1, 8050 Freising, (08161) 80-0; Kurfurstendamm 195-196, 1000 Berlin 15, (030) 8 82 73 65; Dusseldorfer Strae 40, 6236 Eschborn 1, (06196) 80 70; Hollestrae 3, 4300 Essen 1, (0201) 23 66 40; Kirchhorster Strae 2, 3000 Hannover 51, (0511) 64 68-0; Maybachstrae II, 7302 Ostfildern 2 (Nellingen), (0711) 3003 257. HOLLAND: Texas Instruments Holland B.V., Hogehilweg 19, Postbus 12995, 1100 AZ Amsterdam-Zuidoost, Holland, (020) 5602911. HONG KONG: Texas Instruments Hong Kong Ltd., 8th Floor, World Shipping Centre, 7 Canton Road, Kowloon, Hong Kong, 737-0338. HUNGARY: Texas Instruments Representation, Budaorsi ut.42, 1112 Budapest, Hungary, (1) 1 66 66 17. IRELAND: Texas Instruments Ireland Ltd., 7/8 Harcourt Street, Dublin 2, Ireland, (01) 755233. ITALY: Texas Instruments Italia S.p.A., Centro Direzionale Colleoni, Palazzo Perseo-Via Paracelso 12, 20041 Agrate Brianza (Mi), Italy, (039) 63221; Via Castello della Magliana, 38, 00148 Roma, Italy (06) 657 2651. JAPAN: Texas Instruments Japan Ltd., Aoyama Fuji Building 3-6-12 Kita-Aoyama Minato-ku, Tokyo, Japan 107, 03-498-2111; MS Shibaura Building 9F, 4-13-23 Shibaura, Minato-ku, Tokyo, Japan 108, 03-769-8700; Nissho-iwai Building 5F, 2-5-8 Imabashi, Chuou-ku, Osaka, Japan 541, 06-204-1881; Dai-ni Toyota Building Nishi-kan 7F, 4-10-27 Meieki, Nakamura-ku, Nagoya, Japan 450, 052-583-8691; Kanazawa Oyama-cho Daiichi Seimei Building 6F, 3-10 Oyama-cho, Kanazawa-shi, Ishikawa, Japan 920, 0762-23-5471; Matsumoto Showa Building 6F, 1-2-11 Fukashi, Matsumoto-shi, Nagano, Japan 390 0263-33-1060; Daiichi Olympic Tachikawa Building 6F, 1-25-12, Akebono-cho, Tachikawa-shi, Tokyo, Japan 190, 0425-27-6760; Yokohama Business Park East Tower 10F, 134 Goudo-cho Hodogaya-ku, Yokohama-shi, Kanagawa, Japan 240, 045-338-1220; Nihon Seimei Kyoto Yasaka Building 5F, 843-2, Higashi-Shiokohji-cho, Higashi-iru, Nishinotoh-in, Shiokohji-dori, Shimogyo-ku, Kyoto, Japan 600, 075-341-7713; Sumitomo Seimei Kumagaya Bldg. 8F, 2-44 Yayoi, Kumagaya-shi, Saitama, Japan 360, 0485-22-2440; 2597-1, Aza Harudai, Oaza Yasaka, Kitsuki-shi, Oita, Japan 873, 09786-3-3211. KOREA: Texas Instruments Korea Ltd., 28th Floor, Trade Tower, 159-1, Samsung-Dong, Kangnam-ku Seoul, Korea, 2 551-2800.
MALAYSIA: Texas Instruments Malaysia, Sdn. Bhd., Asia Pacific, Lot 36.1 #Box 93, Menara Maybank, 100 Jalan Tun Perak, 50050 Kuala Lumpur, Malaysia, 3-230-6001. MEXICO: Texas Instruments de Mexico S.A., de C.V., Alfonso Reyes 115, Col. Hipodromo Condesa, Mexico, D.F., 06170, 5-515-6081. NORWAY: Texas Instruments Norge A/S, B.P. 106, Refstad (Sinsenveien 53), 0513 Oslo 5, Norway, (02) 155 090. PEOPLE'S REPUBLIC OF CHINA: Texas Instruments China Inc., Beijing Representative Office, 7-05 CITIC Building, 19 Jianguomenwai Dajie, Beijing, China, 500-2255, Ext. 3750. PHILIPPINES: Texas Instruments Asia Ltd., Philippines Branch, 14th Floor, Ba-Lepanto Building, 8747 Paseo de Roxas, 1226 Makati, Metro Manila, Philippines, 2-817-6031. PORTUGAL: Texas Instruments Equipamento Electronico (Portugal) LDA, Ing. Frederico Ulricho, 2650 Moreira Da Maia, 4470 Maia, Portugal (2) 948 1003. SINGAPORE (& INDIA, INDONESIA, MALAYSIA, THAILAND): Texas Instruments Singapore (PTE) Ltd., Asia Pacific, 101 Thomson Road, #23-01, United Square, Singapore 1130, 350-8100. SPAIN: Texas Instruments Espana S.A., c/Gobelas 43, Urbanizasion La Florida, 28023, Madrid, Spain, (91) 372 8051; c/Diputacion, 279-3-5, 08007 Barcelona, Spain, (93) 317 91 80. SWEDEN: Texas Instruments International Trade Corporation (Sverigefilialen), Box 30, S-164 93 Kista, Sweden, (08) 752 58 00. SWITZERLAND: Texas Instruments Switzerland AG, Riedstrasse 6, CH-8953 Dietikon, Switzerland, (01) 744 2811. TAIWAN: Texas Instruments Taiwan Limited, Taipei Branch, 10th Floor Bank Tower, 205 Tung Hwa N. Road, Taipei, Taiwan, 10592 Republic of China, (02) 713-9311. UNITED KINGDOM: Texas Instruments Ltd., Manton Lane, Bedford, England, MK41 7PA, (0234) 270 111.
TI Authorized North American Distributors
Alliance Electronics, Inc. (military product only) Almac/Arrow Anthem Electronics Arrow/Schweber Future Electronics (Canada) GRS Electronics Co., Inc. * Hall-Mark Electronics Marshall Industries Newark Electronics * Wyle Laboratories Zeus Components Rochester Electronics, Inc. (obsolete product only) *Not authorized for TI military products
B0293 (c)1993 Texas Instruments Incorporated 15
TI Authorized TI North American Sales North American Offices Distributors
ALABAMA: Huntsville: (205) 837-7530 ARIZONA: Phoenix: (602) 995-1007 CALIFORNIA: Irvine: (714) 660-1200 San Diego: (619) 278-9600 Santa Clara: (408) 980-9000 Woodland Hills: (818) 704-8100 COLORADO: Aurora: (303) 368-8000 CONNECTICUT: Wallingford: (203) 269-0074 FLORIDA: Altamonte Springs: (407) 260-2116 Fort Lauderdale: (305) 973-8502 Tampa: (813) 885-7588 GEORGIA: Norcross: (404) 662-7967 ILLINOIS: Arlington Heights: (708) 640-3000 INDIANA: Carmel: (317) 573-6400 Fort Wayne: (219) 489-4697 KANSAS: Overland Park: (913) 451-4511 MARYLAND: Columbia: (410) 964-2003 MASSACHUSETTS: Waltham: (617) 895-9100 MICHIGAN: Farmington Hills: (313) 553-1581 MINNESOTA: Eden Prairie: (612) 828-9300 MISSOURI: St. Louis: (314) 821-8400 NEW JERSEY: Iselin: (908) 750-1050 NEW MEXICO: Albuquerque: (505) 345-2555 NEW YORK: East Syracuse: (315) 463-9291 Fishkill: (914) 897-2900 Melville: (516) 454-6600 Pittsford: (716) 385-6770 NORTH CAROLINA: Charlotte: (704) 527-0930 Raleigh: (919) 876-2725 OHIO: Beachwood: (216) 765-7258 Beavercreek: (513) 427-6200 OREGON: Beaverton: (503) 643-6758 PENNSYLVANIA: Blue Bell: (215) 825-9500 PUERTO RICO: Hato Rey: (809) 753-8700 TEXAS: Austin: (512) 250-6769 Dallas: (214) 917-1264 Houston: (713) 778-6592 Midland: (915) 561-7137 UTAH: Salt Lake CIty: (801) 466-8972 WISCONSIN: Waukesha: (414) 798-1001 CANADA: Nepean: (613) 726-1970 Richmond Hill: (416) 884-9181 St. Laurent: (514) 335-8392 Alliance Electronics, Inc. (military product only) Almac/Arrow Anthem Electronics Arrow/Schweber Future Electronics (Canada) GRS Electronics Co., Inc.* Hall-Mark Electronics Marshall Industries Newark Electronics* Rochester Electronics, Inc. (obsolete product only) Wyle Laboratories Zeus Components *Not authorized for TI military products
TI Distributors
ALABAMA: Arrow/Schweber (205) 837-6955; Hall-Mark (205) 837-8700; Marshall (205) 881-9235. ARIZONA: Anthem (602) 966-6600; Arrow/Schweber (602) 437-0750; Hall-Mark (602) 431-0030; Marshall (602) 496-0290; Wyle (602) 437-2088. CALIFORNIA: Los Angeles/Orange County: Anthem (818) 775-1333, (714) 768-4444; Arrow/Schweber (818) 380-9686, (714) 587-0404; Hall-Mark (818) 773-4500, (714) 727-6000; Marshall (818) 878-7000, (714) 458-5301; Wyle (818) 880-9000, (714) 863-9953; Zeus (714) 921-9000, (818) 889-3838; Sacramento: Anthem (916) 624-9744; Hall-Mark (916) 624-9781; Marshall (916) 635-9700; Wyle (916) 638-5282; San Diego: Anthem (619) 453-9005; Arrow/Schweber (619) 565-4800; Hall-Mark (619) 268-1201; Marshall (619) 627-4140; Wyle (619) 565-9171; Zeus (619) 277-9681; San Francisco Bay Area: Anthem (408) 453-1200; Arrow/Schweber (408) 441-9700, (510) 490-9477; Hall-Mark (408) 432-4000; Marshall (408) 942-4600; Wyle (408) 727-2500; Zeus (408) 629-4789. COLORADO: Anthem (303) 790-4500; Arrow/Schweber (303) 799-0258; Hall-Mark (303) 790-1662; Marshall (303) 451-8383; Wyle (303) 457-9953. CONNECTICUT: Anthem (203) 575-1575; Arrow/Schweber (203) 265-7741; Hall-Mark (203) 271-2844; Marshall (203) 265-3822. FLORIDA: Fort Lauderdale: Arrow/Schweber (305) 429-8200; Halll-Mark (305) 971-9280; Marshall (305) 977-4880; Orlando: Arrow/Schweber (407) 333-9300; Hall-Mark (407) 830-5855; Marshall (407) 767-8585; Zeus (407) 788-9100; Tampa: Hall-Mark (813) 541-7440; Marshall (813) 573-1399. GEORGIA: Arrow/Schweber (404) 497-1300; Hall-Mark (404) 623-4400; Marshall (404) 923-5750. ILLINOIS: Anthem (708) 884-0200; Arrow/Schweber (708) 250-0500; Hall-Mark (708) 860-3800; Marshall (708) 490-0155; Newark (312)784-5100. INDIANA: Arrow/Schweber (317) 299-2071; Hall-Mark (317) 872-8875; Marshall (317) 297-0483. IOWA: Arrow/Schweber (319) 395-7230. KANSAS: Arrow/Schweber (913) 541-9542; Hall-Mark (913) 888-4747; Marshall (913) 492-3121. MARYLAND: Anthem (301) 995-6640; Arrow/Schweber (301) 596-7800; Hall-Mark (301) 988-9800; Marshall (301) 622-1118; Zeus (301) 997-1118. MASSACHUSETTS: Anthem (508) 657-5170; Arrow/Schweber (508) 658-0900; Hall-Mark (508) 667-0902; Marshall (508) 658-0810; Wyle (617) 272-7300; Zeus (617) 246-8200.
MICHIGAN: Detroit: Arrow/Schweber (313) 416-5800; Hall-Mark (313) 416-5800; Marshall (313) 525-5850; Newark (313) 967-0600. MINNESOTA: Anthem (612) 944-5454; Arrow/Schweber (612) 941-5280; Hall-Mark (612) 881-2600; Marshall (612) 559-2211. MISSOURI: Arrow/Schweber (314) 567-6888; Hall-Mark (314) 291-5350; Marshall (314) 291-4650. NEW JERSEY: Anthem (201) 227-7960; Arrow/Schweber (201) 227-7880, (609) 596-8000; Hall-Mark (201) 515-3000, (609) 235-1900; Marshall (201) 882-0320, (609) 234-9100. NEW MEXICO: Alliance (505) 292-3360. NEW YORK: Long Island: Anthem (516) 864-6600; Arrow/Schweber (516) 231-1000; Hall-Mark (516) 737-0600; Marshall (516) 273-2424; Zeus (914) 937-7400; Rochester: Arrow/Schweber (716) 427-0300; Hall-Mark (716) 425-3300; Marshall (716) 235-7620; Syracuse: Marshall (607) 785-2345. NORTH CAROLINA: Arrow/Schweber (919) 876-3132; Hall-Mark (919) 872-0712; Marshall (919) 878-9882. OHIO: Cleveland: Arrow/Schweber (216) 248-3990; Hall-Mark (216) 349-4632; Marshall (216) 248-1788; Columbus: Hall-Mark (614) 888-3313; Dayton: Arrow/Schweber (513) 435-5563; Marshall (513) 898-4480; Zeus (513) 293-6162. OKLAHOMA: Arrow/Schweber (918) 252-7537; Hall-Mark (918) 254-6110. OREGON: Almac/Arrow (503) 629-8090; Anthem (503) 643-1114; Marshall (503) 644-5050; Wyle (503) 643-7900. PENNSYLVANIA: Anthem (215) 443-5150; Arrow/Schweber (215) 928-1800; GRS (215) 922-7037; (609) 964-8560; Marshall (412) 788-0441. TEXAS: Austin: Arrow/Schweber (512) 835-4180; Hall-Mark (512) 258-8848; Marshall (512) 837-1991; Wyle (512) 345-8853; Dallas: Anthem (214) 238-7100; Arrow/Schweber (214) 380-6464; Hall-Mark (214) 553-4300; Marshall (214) 233-5200; Wyle (214) 235-9953; Zeus (214) 783-7010; Houston: Arrow/Schweber (713) 530-4700; Hall-Mark (713) 781-6100; Marshall (713) 467-1666; Wyle (713) 879-9953. UTAH: Anthem (801) 973-8555; Arrow/Schweber (801) 973-6913; Hall-Mark (801) 269-0416; Marshall (801) 973-2288; Wyle (801) 974-9953. WASHINGTON: Almac/Arrow (206) 643-9992; Anthem (206) 483-1700; Marshall (206) 486-5747; Wyle (206) 881-1150. WISCONSIN: Arrow/Schweber (414) 792-0150; Hall-Mark (414) 797-7844; Marshall (414) 797-8400. CANADA: Calgary: Future (403) 235-5325; Edmonton: Future (403) 438-2858; Montreal: Arrow/Schweber (514) 421-7411; Future (514) 694-7710; Marshall (514) 694-8142; Ottawa: Arrow/Schweber (613) 226-6903; Future (613) 820-8313; Quebec: Future (418) 897-6666; Toronto: Arrow/Schweber (416) 670-7769; Future (416) 612-9200; Marshall (416) 458-8046; Vancouver: Arrow/Schweber (604) 421-2333; Future (604) 294-1166.
TI Regional Technology Centers
CALIFORNIA: Irvine: (714) 660-8140 Santa Clara: (408) 748-2222 GEORGIA: Norcross: (404) 662-7945 ILLINOIS: Arlington Heights: (708) 640-2909 INDIANA: Indianapolis: (317) 573-6400 MASSACHUSETTS: Waltham: (617) 895-9196 MEXICO: Mexico City: 491-70834 MINNESOTA: Minneapolis: (612) 828-9300 TEXAS: Dallas: (214) 917-3881 CANADA: Nepean: (613) 726-1970
TI Die Processors
Chip Supply Elmo Semiconductor Minco Technology Labs (407) 298-7100 (818) 768-7400 (512) 834-2022
Customer Response Center
TOLL FREE: OUTSIDE USA: (800) 336-5236 (214) 995-6611 (8:00 a.m. - 5:00 p.m. CST)
D0293
(c)1993 Texas Instruments Incorporated
Printed in U.S.A.
SRPS028A
IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL APPLICATIONS"). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER'S RISK. In order to minimize risks associated with the customer's applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI's publication of information regarding any third party's products or services does not constitute TI's approval, warranty or endorsement thereof.
Copyright (c) 1998, Texas Instruments Incorporated


▲Up To Search▲   

 
Price & Availability of SRPS028A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X