![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
PM100CSA060 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 IntellimodTM Module Three Phase IGBT Inverter Output 100 Amperes/600 Volts A B R AD 12 3 4 W Q AB U Y (4 TYP.) U U AB 5678 9 11 13 15 17 19 10 12 14 16 18 M M S AG AD (15 TYP.) Z - DIA. (4 TYP.) F E C AA - THD (6 TYP.) U W V U W X X 1. V UPC 2. UFO 3. U P 4. V UPI 5. V VPC 6. VFO 7. V P 8. V VPI 9. V WPC 10. WFO 11. W P 12. V WPI 13. V NC 14. V NI 15. NC 16. U N 17. V N 18. W N 19. FO B P N AG K J D 2.54 MM DIA. (2 TYP.) 0.5 MM SQ. PIN (19 TYP.) J P AE T GH N V AF L AC OUT V CC OUT V CC OUT V CC OUT V CC GND GND GND GND GND GND GND GND GND GND GND GND TEMP OUT V CC OUT V CC FO FO FO FO FO SI SI IN SI SI SI SI FO IN IN IN IN IN Description: Powerex IntellimodTM Intelligent Power Modules are isolated base modules designed for power switching applications operating at frequencies to 20kHz. Built-in control circuits provide optimum gate drive and protection for the IGBT and free-wheel diode power devices. Features: Complete Output Power Circuit Gate Drive Circuit V WPC WP W FO V UPC UP UFO V VPC VP V FO V WPI NC N W V U V UPI V VPI V NC WN V NI FO NC VN UN P Outline Drawing and Circuit Diagram Dimensions A B C D E F G H J K L M N P Q R Inches 4.330.04 3.740.02 3.500.04 3.27 2.910.02 2.44 1.28 1.24 1.02 0.94 Millimeters 110.01.0 95.00.5 89.01.0 83.0 74.00.5 62.0 32.6 31.6 26.0 24.0 Dimensions S T U V W X Y Z AA AB AC AD AE AF AG Inches 0.67 0.52 0.39 0.32 0.30 0.24 0.24 Rad. 0.22 Dia. Metric M5 0.127 0.10 0.08 0.07 0.06 0.02 Millimeters 17.0 13.2 10.0 8.0 7.5 6.0 Rad. 6.0 Dia. 5.5 M5 3.22 2.6 2.0 1.8 1.6 0.5 Protection Logic - Short Circuit - Over Current - Over Temperature - Under Voltage Applications: Inverters UPS Motion/Servo Control Power Supplies Ordering Information: Example: Select the complete part number from the table below -i.e. PM100CSA060 is a 600V, 100 Ampere IntellimodTM Intelligent Power Module. Type PM Current Rating Amperes 100 VCES Volts (x 10) 60 0.87 +0.06/-0 22.0 +1.5/-0.0 0.79 0.76 0.75 0.708 0.670 20.0 19.4 19.0 17.98 17.02 481 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM100CSA060 IntellimodTM Module Three Phase IGBT Inverter Output 100 Amperes/600 Volts Absolute Maximum Ratings, Tj = 25C unless otherwise specified Characteristics Power Device Junction Temperature Storage Temperature Case Operating Temperature Mounting Torque, M5 Mounting Screws Mounting Torque, M5 Main Terminal Screws Module Weight (Typical) Supply Voltage Protected by OC and SC (VD = 13.5 - 16.5V, Inverter Part) Isolation Voltage, AC 1 minute, 60Hz Sinusoidal Symbol Tj Tstg TC -- -- -- VCC(prot.) VRMS PM100CSA060 -20 to 150 -40 to 125 -20 to 100 17 17 550 400 2500 Units C C C in-lb in-lb Grams Volts Volts Control Sector Supply Voltage Applied between (VUP1-VUPC, VVP1-VVPC, VWP1-VWPC, VN1-VNC) Input Voltage Applied between (UP, VP, WP, UN, VN, WN) Fault Output Supply Voltage (Applied between FO and VC) Fault Output Current VD VCIN VFO IFO 20 20 20 20 Volts Volts Volts mA IGBT Inverter Sector Collector-Emitter Voltage (VD = 15V, VCIN =15V) Collector Current, Peak Collector Current, Supply Voltage (Applied between P - N) Supply Voltage, Surge (Applied between P - N) Collector Dissipation VCES IC ICP VCC VCC(surge) PC 600 100 200 450 500 403 Volts Amperes Amperes Volts Volts Watts 482 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM100CSA060 IntellimodTM Module Three Phase IGBT Inverter Output 100 Amperes/600 Volts Electrical and Mechanical Characteristics, Tj = 25C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units Control Sector Over Current Trip Level Inverter Part Short Circuit Trip Level Inverter Part Over Current Delay Time Over Temperature Protection OC SC toff(OC) OT OTR Supply Circuit Under Voltage Protection UV UVR Supply Voltage VD ID VCIN(on) VCIN(off) fPWM IFO(H) IFO(L) Minimum Fault Output Pulse Width tFO -20C T 125C -20C T 125C VD = 15V Trip Level Reset Level Trip Level Reset Level Applied between VUP1-VUPC, VVP1-VVPC, VWP1-VWPC, VN1-VNC Circuit Current VD = 15V, VCIN = 15V, VN1-VNC VD = 15V, VCIN = 15V, VXP1-VXPC Input ON Threshold Voltage Input OFF Threshold Voltage PWM Input Frequency Fault Output Current Applied between UP, VP, WP, UN, VN, WN 3Sinusoidal VD = 15V, VFO = 15V VD = 15V, VFO = 15V VD = 15V -- -- 1.2 1.7 -- -- -- 1.0 40 13 1.5 2.0 15 -- 10 1.8 55 18 1.8 2.3 20 0.01 15 -- mA mA Volts Volts kHz mA mA mS 158 -- -- 111 -- 11.5 -- 13.5 240 360 10 118 100 12.0 12.5 15 -- -- -- 125 -- 12.5 -- 16.5 Amperes Amperes S C C Volts Volts Volts 483 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM100CSA060 IntellimodTM Module Three Phase IGBT Inverter Output 100 Amperes/600 Volts Electrical and Mechanical Characteristics, Tj = 25C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units IGBT Inverter Sector Collector Cutoff Current ICEX VFM VCE(sat) VCE = VCEX, Tj = 25C VCE = VCEX, Tj = 125C Diode Forward Voltage Collector-Emitter Saturation Voltage -IC = 100A, VD = 15V, VCIN = 15V VD = 15V, VCIN = 0V, IC = 100A VD = 15V, VCIN = 0V, IC = 100A, Tj = 125C Inductive Load Switching Times ton trr tC(on) toff tC(off) VD = 15V, VCIN = 0 ~ 15V VCC = 300V, IC = 100A Tj = 125C 0.4 -- -- -- -- 0.8 0.15 0.4 2.0 0.6 2.0 0.3 1.0 2.9 1.2 S S S S S -- -- -- -- -- -- -- 2.2 1.8 1.75 1.0 10 3.3 2.7 2.63 mA mA Volts Volts Volts Control Sector Thermal Characteristics Characteristic Junction to Case Thermal Resistance Symbol Rth(j-c)Q Rth(j-c)D Contact Thermal Resistance Rth(c-f) Condition Each IGBT Each FWDi Case to Fin Per Module, Thermal Grease Applied Min. -- -- -- Typ. -- -- -- Max. 0.31 0.7 0.027 Units C/Watt C/Watt C/Watt Recommended Conditions for Use Characteristic Supply Voltage Symbol VCC VD Input ON Voltage Input OFF Voltage PWM Input Frequency Minimum Dead Time VCIN(on) VCIN(off) fPWM tDEAD Condition Applied across P-N Terminals Applied between VUP1-VUPC, VN1-VNC, VVP1-VVPC, VWP1-VWPC Applied between UP, VP, WP, UN, VN, WN Using Application Circuit Input Signal 0 ~ 0.8 4.0 ~ VD 5 ~ 20 2.5 Volts Volts kHz S Value 0 ~ 400 15 1.5 Units Volts Volts 484 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM100CSA060 IntellimodTM Module Three Phase IGBT Inverter Output 100 Amperes/600 Volts SATURATION VOLTAGE CHARACTERISTICS (TYPICAL) COLLECTOR-EMITTER SATURATION VOLTAGE CHARACTERISTICS (TYPICAL) OUTPUT CHARACTERISTICS (TYPICAL) 3 COLLECTOR-EMITTER SATURATION VOLTAGE VCE(sat), (VOLTS) SATURATION VOLTAGE VCE(sat), (VOLTS) 3 VD = 15V VCIN = 0V Tj = 25oC Tj = 125oC 160 Tj = 25oC COLLECTOR CURRENT, IC, (AMPERES) VCIN = 0V 15 VD = 17V 120 2 2 13 80 1 1 IC = 100A VCIN = 0V Tj = 25oC Tj = 125oC 40 0 0 40 80 120 160 200 COLLECTOR CURRENT, IC, (AMPERES) 0 0 12 14 16 18 20 SUPPLY VOLTAGE, VD, (VOLTS) 0 0 1 2 3 COLLECTOR-EMITTER VOLTAGE, VCE, (VOLTS) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL) REVERSE RECOVERY CURRENT VS. COLLECTOR CURRENT (TYPICAL) 101 VCC = 300V VD = 15V Tj = 25oC Tj = 125oC toff 101 VCC = 300V VD = 15V Tj = 25oC Tj = 125oC 100 REVERSE RECOVERY TIME, trr, (S) 102 VCC = 300V VD = 15V Tj = 25oC Tj = 125oC Irr REVERSE RECOVERY CURRENT, Irr, (AMPERES) 100 ton SWITCHING TIMES, tc(on), tc(off), (s) SWITCHING TIMES, ton, toff, (s) 100 tc(off) 10-1 trr 101 tc(on) 10-1 100 101 COLLECTOR CURRENT, IC, (AMPERES) 102 10-1 100 101 COLLECTOR CURRENT, IC, (AMPERES) 102 10-2 100 101 EMITTER CURRENT, IE, (AMPERES) 100 102 DIODE FORWARD CHARACTERISTICS OVER CURRENT TRIP LEVEL VS. SUPPLY VOLTAGE (TYPICAL) OVER CURRENT TRIP LEVEL TEMPERATURE DEPENDENCY (TYPICAL) 102 OVER CURRENT TRIP LEVEL % (NORMALIZED) DIODE FORWARD CURRENT, -IF, (AMPERES) 120 OVER CURRENT TRIP LEVEL % (NORMALIZED) 120 Tj = 25oC VD = 15V VD = 15V Tj = 25oC Tj = 125oC 100 100 80 80 101 60 60 40 40 100 0 0.5 1.0 1.5 2.0 2.5 DIODE FORWARD VOLTAGE, VFM, (VOLTS) 0 0 12 14 16 18 20 SUPPLY VOLTAGE, VD, (VOLTS) 0 -50 0 50 100 150 JUNCTION TEMPERATURE, Tj, (oC) 485 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM100CSA060 IntellimodTM Module Three Phase IGBT Inverter Output 100 Amperes/600 Volts CONTROL SUPPLY VOLTAGE TRIP-RESET LEVEL TEMPERATURE DEPENDENCY (TYPICAL) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (IGBT) TRANSIENT IMPEDANCE, Zth(j-c), (NORMALIZED VALUE) FAULT OUTPUT PULSE WIDTH VS. TEMPERATURE (TYPICAL) 120 FAULT OUTPUT PULSE WIDTH % (NORMALIZED) 15 VD = 15V UVt UVr 101 100 UV TRIP-RESET LEVEL, UVt, UVr, (VOLTS) 14 100 80 13 10-1 60 12 40 11 10-2 SINGLE PULSE STANDARD VALUE = Rth(j-c)Q = 0.31oC/W 0 -50 0 50 100 o 0 150 -50 0 50 100 o 150 10-3 10-3 10-2 10-1 TIME, (s) 100 101 JUNCTION TEMPERATURE, Tj, ( C) JUNCTION TEMPERATURE, Tj, ( C) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (FWDi) TRANSIENT IMPEDANCE, Zth(j-c), (NORMALIZED VALUE) 101 100 10-1 10-2 SINGLE PULSE STANDARD VALUE = Rth(j-c)D = 0.70oC/W 10-3 10-3 10-2 10-1 TIME, (s) 100 101 486 |
Price & Availability of PM100CSA060
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |