 System Hardware Monitor with Remote Diode Thermal Sensing ADM1024
FEATURES Up to 9 Measurement Channels Inputs Programmable-to-Measure Analog Voltage, Fan Speed, or External Temperature External Temperature Measurement with Remote Diode (2 Channels) On-Chip Temperature Sensor 5 Digital Inputs for VID Bits LDCM Support System Management Bus (SMBus) Chassis Intrusion Detect Interrupt and Overtemperature Outputs Programmable RESET Input Pin Shutdown Mode to Minimize Power Consumption Limit Comparison of All Monitored Values APPLICATIONS Network Servers and Personal Computers Microprocessor Based Office Equipment Test Equipment and Measuring Instruments GENERAL DESCRIPTION
The ADM1024 is a complete system hardware monitor for microprocessor based systems, providing measurement and limit comparison of various system parameters. Eight measurement inputs are provided; three are dedicated to monitoring 5 V and 12 V power supplies and the processor core voltage. The ADM1024 can monitor a fourth power supply voltage by measuring its own VCC. One input (two pins) is dedicated to a remote temperature-sensing diode. Two more pins can be (continued on page 7)
FUNCTIONAL BLOCK DIAGRAM
VCC VID0/IRQ0 VID1/IRQ1 VID2/IRQ2 VID3/IRQ3 100k PULL-UPS VID4/IRQ4 VID4 AND DEVICE ID REGISTER FAN SPEED COUNTER ADDRESS POINTER REGISTER VID0-3 AND FAN DIVISOR REGISTER
ADM1024
NTEST OUT/ADD SERIAL BUS INTERFACE SDA SCL
CHANNEL MODE REGISTER
VALUE AND LIMIT REGISTERS
FAN1/AIN1 FAN2/AIN2 +VCCP1 +2.5VIN /D2+ +5VIN +12VIN VCCP2 /D2- D1+ D1- POWER TO CHIP VCC BAND GAP TEMPERATURE SENSOR INPUT ATTENUATORS AND ANALOG MULTIPLEXER
LIMIT COMPARATORS INTERRUPT STATUS REGISTERS INT MASK REGISTERS INTERRUPT MASKING 100k CONFIGURATION REGISTERS INT 100k THERM VCC
TEMPERATURE CONFIGURATION REGISTER
CI VCC
10-BIT ADC
ANALOG OUTPUT REGISTER AND 8-BIT DAC CHASSIS INTRUSION CLEAR REGISTER 100k
NTEST IN/AOUT VCC
2.5V BAND GAP REFERENCE
RESET
GND
REV. B
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781/329-4700 www.analog.com Fax: 781/326-8703 (c) 2004 Analog Devices, Inc. All rights reserved.
ADM1024-SPECIFICATIONS1, 2 (T = T
A
MIN
to TMAX, VCC = VMIN to VMAX, unless otherwise noted.)
Max 5.5 3.5 145 3 2 5 150 9 Unit Test Conditions/Comments V mA mA A C C C C C C A A
Parameter POWER SUPPLY Supply Voltage, VCC Supply Current, ICC
Min 2.8
Typ 3.30 1.4 1.0 45
Interface Inactive, ADC Active ADC Inactive, DAC Active Shutdown Mode 0C TA 100C TA = 25C 0C TA 100C 25C High Level Low Level
TEMPERATURE-TO-DIGITAL CONVERTER Internal Sensor Accuracy Resolution External Diode Sensor Accuracy Resolution Remote Sensor Source Current ANALOG-TO-DIGITAL CONVERTER (INCLUDING MUX AND ATTENUATORS) Total Unadjusted Error, TUE (12 VIN)3 TUE (AIN, VCCP, 2.5 VIN, 5 VIN) Differential Nonlinearity, DNL Power Supply Sensitivity Conversion Time (Analog Input or Int. Temp.) Conversion Time (External Temperature)4 Input Resistance (2.5 V, 5 V, 12 V, VCCP1, VCCP2) Input Resistance (AIN1, AIN2) ANALOG OUTPUT Output Voltage Range Total Unadjusted Error, TUE Full-Scale Error Zero-Scale Error Differential Nonlinearity, DNL Integral Nonlinearity Output Source Current Output Sink Current FAN RPM-TO-DIGITAL CONVERTER Accuracy Full-Scale Count FAN1 and FAN2 Nominal Input RPM5 1 3 1 110 6.5
80 4
80
1 754.8 9.6 140 5
4 3 1 856.8 200
% % LSB %/V s ms k M
0C TA 100C4
0 1 2 1 2 1
2.5 3 5 1
V % IL = 2 mA % LSB No Load LSB Monotonic by Design LSB mA mA % rpm rpm rpm rpm kHz V V 0C TA 100C Divisor = 1, Fan Count = 153 Divisor = 2, Fan Count = 153 Divisor = 3, Fan Count = 153 Divisor = 4, Fan Count = 153 0C TA 100C IOUT = +3.0 mA, VCC = 2.85 V - 3.60 V IOUT = -3.0 mA, VCC = 2.85 V - 3.60 V
12 255 8800 4400 2200 1100 22.5
Internal Clock Frequency DIGITAL OUTPUTS NTEST_OUT Output High Voltage, VOH Output Low Voltage, VOL OPEN-DRAIN DIGITAL OUTPUTS6 (INT, THERM, RESET) Output Low Voltage, VOL High Level Output Current, IOH RESET and CI Pulsewidth OPEN-DRAIN SERIAL DATA BUS OUTPUT (SDA) Output Low Voltage, VOL High Level Output Current, IOH
19.8 2.4
25.2
0.4
20
0.1 45
0.4 100
V A ms V A
IOUT = -3.0 mA, VCC = 3.60 V VOUT = VCC
0.1
0.4 100
IOUT = -3.0 mA, VCC = 2.85 V - 3.60 V VOUT = VCC
-2-
REV. B
ADM1024
Parameter SERIAL BUS DIGITAL INPUTS (SCL, SDA) Input High Voltage, VIH Input Low Voltage, VIL Hysteresis Glitch Immunity DIGITAL INPUT LOGIC LEVELS7 (ADD, CI, RESET, VID0-VID4, FAN1, FAN2) Input High Voltage, VIH Input Low Voltage, VIL NTEST_IN Input High Voltage, VIH DIGITAL INPUT CURRENT Input High Current, IIH Input Low Current, IIL Input Capacitance, CIN SERIAL BUS TIMING Clock Frequency, fSCLK Glitch Immunity, tSW Bus Free Time, tBUF Start Setup Time, tSU; STA Start Hold Time, tHD; STA SCL Low Time, tLOW SCL High Time, tHIGH SCL, SDA Rise Time, tr SCL, SDA Fall Time, tf Data Setup Time, tSU; DAT Data Hold Time, tHD; DAT
8
Min
Typ
Max
Unit Test Conditions/Comments
2.2 0.8 500 100
V V mV ns
2.2 0.8 2.2 -1 1 20 400 50 1.3 600 600 1.3 0.6 300 300 100 900
V V V A A pF kHz ns s ns ns s s ns ns ns ns
VCC = 2.85 V - 5.5 V VCC = 2.85 V - 5.5 V VCC = 2.85 V - 5.5 V VIN = VCC VIN = 0
See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1 See Figure 1
NOTES 1 All voltages are measured with respect to GND, unless otherwise specified. 2 Typicals are at T A = 25C and represent most likely parametric norm. Shutdown current typ is measured with V CC = 3.3 V. 3 TUE (Total Unadjusted Error) includes Offset, Gain, and Linearity errors of the ADC, multiplexer, and on-chip input attenuators, including an external series input protection resistor value between 0 k and 1 k. 4 Total monitoring cycle time is nominally m x 755 s + n x 33244 s, where m is the number of channels configured as analog inputs, plus 2 for the internal V CC measurement and internal temperature sensor, and n is the number of channels configured as external temperature channels (D1 and D2). 5 The total fan count is based on two pulses per revolution of the fan tachometer output. 6 Open-drain digital outputs may have an external pull-up resistor connected to a voltage lower or higher than V CC (up to 6.5 V absolute maximum). 7 All logic inputs except ADD are tolerant of 5 V logic levels, even if V CC is less than 5 V. ADD is a three-state input that may be connected to V CC, GND, or left open-circuit. 8 Timing specifications are tested at logic levels of V IL = 0.8 V for a falling edge and V IH = 2.2 V for a rising edge. Specifications subject to change without notice.
tR tLOW
SCL
tF
tHD:STA
tHD:STA
SDA
tHD:DAT
tHIGH
tSU:DAT
tSU:STA
tSU:STO
tBUF
P S S P
Figure 1. Diagram for Serial Bus Timing
REV. B
-3-
ADM1024
ABSOLUTE MAXIMUM RATINGS* PIN CONFIGURATION
NTEST OUT/ADD THERM SDA SCL FAN1/AIN1 FAN2/AIN2 CI GND VCC
1 2 3 4 5 6 24 VID0/IRQ0 23 VID1/IRQ1 22 VID2/IRQ2 21 VID3/IRQ3
Positive Supply Voltage (VCC) . . . . . . . . . . . . . . . . . . . . . 6.5 V Voltage on 12 V VIN Pin . . . . . . . . . . . . . . . . . . . . . . . . . 20 V Voltage on AOUT, N TEST_OUT ADD, 2.5 VIN/D2+ . . . . . . . . . . . . . . . . . . -0.3 V to (VCC + 0.3 V) Voltage on Any Other Input or Output Pin . . -0.3 V to +6.5 V Input Current at Any Pin . . . . . . . . . . . . . . . . . . . . . . . 5 mA Package Input Current . . . . . . . . . . . . . . . . . . . . . . . 20 mA Maximum Junction Temperature (TJ max) . . . . . . . . . . 150C Storage Temperature Range . . . . . . . . . . . . -65C to +150C Lead Temperature, Soldering Vapor Phase 60 sec . . . . . . . . . . . . . . . . . . . . . . . . . . 235C Infrared 15 sec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200C ESD Rating All Pins . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 V
*Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
ADM1024
TOP VIEW
20 VID4/IRQ4 19 +VCCP1
7 (Not to Scale) 18 +2.5VIN /D2+ 8 9 17 VCCP2 /D2- 16 +5VIN 15 +12VIN 14 D1+ 13 D1-
INT 10 NTEST IN/AOUT 11 RESET 12
THERMAL CHARACTERISTICS
24-Lead, Small Outline Package:
JA
= 50C/W,
JC
= 10C/W
ORDERING GUIDE
Model ADM1024ARU ADM1024ARU-REEL ADM1024ARU-REEL7 ADM1024ARUZ* ADM1024ARUZ-REEL* ADM1024ARUZ-REEL7* EVAL-ADM1024EB
*Z = Pb-free part.
Temperature Range 0C to 100C 0C to 100C 0C to 100C 0C to 100C 0C to 100C 0C to 100C
Package Description 24-Lead TSSOP 24-Lead TSSOP 24-Lead TSSOP 24-Lead TSSOP 24-Lead TSSOP 24-Lead TSSOP Evaluation Board
Package Option RU-24 RU-24 RU-24 RU-24 RU-24 RU-24
CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the ADM1024 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.
-4-
REV. B
ADM1024
PIN FUNCTION DESCRIPTIONS
Pin No. 1 2 3 4 5 6 7
Mnemonic NTEST_OUT/ADD THERM SDA SCL FAN1/AIN1 FAN2/AIN2 CI
Description Digital I/O. Dual function pin. This is a three-state input that controls the two LSBs of the Serial Bus Address. This pin functions as an output when doing a NAND test. Digital I/O. Dual function pin. This pin functions as an interrupt output for temperature interrupts only, or as an interrupt input for fan control. It has an on-chip 100 k pull-up resistor. Digital I/O. Serial bus bidirectional data. Open-drain output. Digital Input. Serial bus clock. Programmable Analog/Digital Input. 0 V to 2.5 V analog input or digital (0 to VCC) amplitude fan tachometer input. Programmable Analog/Digital Input. 0 V to 2.5 V analog input or digital (0 to VCC) amplitude fan tachometer input. Digital I/O. An active high input from an external latch that captures a Chassis Intrusion event. This line can go high without any clamping action, regardless of the powered state of the ADM1024. The ADM1024 provides an internal open drain on this line, controlled by Bit 6 of Register 40h or Bit 7 of Register 46h, to provide a minimum 20 ms pulse on this line to reset the external Chassis Intrusion Latch. System Ground Power (2.8 V to 5.5 V). Typically powered from 3.3 V power rail. Bypass with the parallel combination of 10 F (electrolytic or tantalum) and 0.1 F (ceramic) bypass capacitors. Digital Output. Interrupt request (open-drain). The output is enabled when Bit 1 of Register 40h is set to 1. The default state is disabled. It has an on-chip 100 k pull-up resistor. Digital Input/Analog Output. An active-high input that enables NAND Test mode board-level connectivity testing. Refer to the section on NAND testing. Also functions as a programmable analog output when NAND Test is not selected. Digital I/O. Master Reset, 5 mA driver (open drain), active low output with a 45 ms minimum pulsewidth. Set using Bit 4 in Register 40h. Also acts as reset input when pulled low (e.g., poweron reset). It has an on-chip 100 k pull-up resistor. Analog Input. Connected to cathode of first external temperature-sensing diode. Analog Input. Connected to anode of first external temperature-sensing diode. Programmable Analog Input. Monitors 12 V supply. Analog Input. Monitors 5 V supply. Programmable Analog Input. Monitors second processor core voltage or cathode of second external temperature-sensing diode. Programmable Analog Input. Monitors 2.5 V supply or anode of second external temperaturesensing diode. Analog Input. Monitors first processor core voltage (0 V to 3.6 V). Digital Input. Core Voltage ID readouts from the processor. This value is read into the VID4 Status Register. Can also be reconfigured as an interrupt input. It has an on-chip 100 k pull-up resistor. Digital Input. Core Voltage ID readouts from the processor. This value is read into the VID0-VID3 Status Register. Can also be reconfigured as an interrupt input. It has an on-chip 100 k pull-up resistor. Digital Input. Core Voltage ID readouts from the processor. This value is read into the VID0-VID3 Status Register. Can also be reconfigured as an interrupt input. It has an on-chip 100 k pull-up resistor. Digital Input. Core Voltage ID readouts from the processor. This value is read into the VID0-VID3 Status Register. Can also be reconfigured as an interrupt input. It has an on-chip 100 k pull-up resistor. Digital Input. Core Voltage ID readouts from the processor. This value is read into the VID0-VID3 Status Register. Can also be reconfigured as an interrupt input. It has an on-chip 100 k pull-up resistor.
8 9 10 11
GND VCC INT NTEST_IN/AOUT
12
RESET
13 14 15 16 17 18 19 20
D1- D1+ +12 VIN +5 VIN VCCP2/D2- +2.5 VIN/D2+ +VCCP1 VID4/IRQ4
21
VID3/IRQ3
22
VID2/IRQ2
23
VID1/IRQ1
24
VID0/IRQ0
REV. B
-5-
ADM1024-Typical Performance Characteristics
30 20
TEMPERATURE ERROR - C
120 100 90
10 DXP TO GND 0 -10 DXP TO VCC (5V) -20 -30 -40 -50 -60 1 10 30 3.3 LEAKAGE RESISTANCE - M 100
80 70
READING
60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 MEASURED TEMPERATURE 90 100 110
TPC 1. Temperature Error vs. PC Board Track Resistance
TPC 4. ADM1024 Reading vs. Pentium(R) III Temperature Measurement
6
25
5
TEMPERATURE ERROR - C 20
250mV p-p REMOTE 3 2
TEMPERATURE ERROR - C
4
15
10
1 100mV p-p REMOTE 0 -1
5
0
50
500
5k
500k 50k FREQUENCY - Hz
5M
50M
-5
1
2.2
3.2 4.7 DXP-DXN CAPACITANCE - nF
7
10
TPC 2. Temperature Error vs. Power Supply Noise Frequency
TPC 5. Temperature Error vs. Capacitance Between D+ and D-
25
10 9
20
TEMPERATURE ERROR - C
TEMPERATURE ERROR - C
100mV p-p 15
8 7 10mV SQ. WAVE 6 5 4 3 2 1
10 50mV p-p 5
0
25mV p-p
-5 50 500 5k 50k 500k FREQUENCY - Hz 5M 50M
0
50
500
5k
50k 100k 500k FREQUENCY - Hz
5M
25M
50M
TPC 3. Temperature Error vs. Common-Mode Noise Frequency
TPC 6. Temperature Error vs. Differential-Mode Noise Frequency
-6-
REV. B
ADM1024
26.5 26.0
STANDBY CURRENT - A
25.5 25.0
VDD = 3.3V
Finally, the ADM1024 monitors the supply from which it is powered, so there is no need for a separate 3.3 V analog input if the chip VCC is 3.3 V. The range of this VCC measurement can be configured for either a 3.3 V or 5 V VCC by Bit 3 of the Channel Mode Register.
SEQUENTIAL MEASUREMENT
24.5 24.0 23.5 23.0 22.5 -40
-20
0
20 40 60 80 TEMPERATURE - C
100
120
When the ADM1024 monitoring sequence is started, it cycles sequentially through the measurement of analog inputs and the temperature sensor, while at the same time the fan speed inputs are independently monitored. Measured values from these inputs are stored in Value Registers. These can be read out over the serial bus, or can be compared with programmed limits stored in the Limit Registers. The results of out-of-limit comparisons are stored in the Interrupt Status Registers, and will generate an interrupt on the INT line (Pin 10). Any or all of the Interrupt Status Bits can be masked by appropriate programming of the Interrupt Mask Register.
PROCESSOR VOLTAGE ID
TPC 7. Standby Current vs. Temperature
(continued from page 1) configured as inputs to monitor a 2.5 V supply and a second processor core voltage, or as a second temperature-sensing input. The remaining two inputs can be programmed as general-purpose analog inputs or as digital fan-speed measuring inputs. Measured values can be read out via an SMBus serial System Management Bus, and values for limit comparisons can be programmed in over the same serial bus. The high speed successive-approximation ADC allows frequent sampling of all analog channels to ensure a fast interrupt response to any out-of-limit measurement. The ADM1024's 2.8 V to 5.5 V supply voltage range, low supply current, and SMBus interface make it ideal for a wide range of applications. These include hardware monitoring and protection applications in personal computers, electronic test equipment, and office electronics.
MEASUREMENT INPUTS
Five digital inputs (VID4 to VID0--Pins 20 to 24) read the processor voltage ID code. These inputs can also be reconfigured as interrupt inputs. The VID pins have internal 100 k pull-up resistors.
CHASSIS INTRUSION
A chassis intrusion input (Pin 7) is provided to detect unauthorized tampering with the equipment.
RESET
A RESET input/output (Pin 12) is provided. Pulling this pin low will reset all ADM1024 internal registers to default values. The ADM1024 can also be programmed to give a low going 45 ms reset pulse at this pin. The RESET pin has an internal, 100 k pull-up resistor.
ANALOG OUTPUT
Programmability of the measurement inputs makes the ADM1024 extremely flexible and versatile. The device has a 10-bit ADC and nine measurement input pins that can be configured in different ways. Pins 5 and 6 can be programmed as general-purpose analog inputs with a range of 0 V to 2.5 V, or as digital inputs to monitor the speed of fans with digital tachometer outputs. The fan inputs can be programmed to accommodate fans with different speeds and different numbers of pulses per revolution from their tachometer outputs. Pins 13 and 14 are dedicated temperature inputs and may be connected to the cathode and anode of an external temperaturesensing diode. Pins 15, 16, and 19 are dedicated analog inputs with on-chip attenuators, configured to monitor 12 V, 5 V, and the processor core voltage, respectively. Pins 17 and 18 may be configured as analog inputs with on-chip attenuators to monitor a second processor core voltage and a 2.5 V supply, or they may be configured as a temperature input and connected to a second temperature-sensing diode. The ADC also accepts input from an on-chip band gap temperature sensor that monitors system-ambient temperature.
The ADM1024 contains an on-chip, 8-bit DAC with an output range of 0 V to 2.5 V (Pin 11). This is typically used to implement a temperature controlled fan by controlling the speed of a fan dependent upon the temperature measured by the on-chip temperature sensor. Testing of board level connectivity is simplified by providing a NAND tree test function. The AOUT (Pin 11) also doubles as a NAND test input, while Pin 1 doubles as a NAND tree output.
INTERNAL REGISTERS OF THE ADM1024
A brief description of the ADM1024's principal internal registers follows. More detailed information on the function of each register is given in Tables VI to XIX. Configuration Registers: Provide control and configuration. Channel Mode Register: Stores the data for the operating modes of the input channels. Address Pointer Register: This register contains the address that selects one of the other internal registers. When writing to the ADM1024, the first byte of data is always a register address, which is written to the Address Pointer Register.
REV. B
-7-
ADM1024
Interrupt (INT) Status Registers: Two registers to provide status of each Interrupt event. These registers are also mirrored at addresses 4Ch and 4Dh. Interrupt (INT) Mask Registers: Allow masking of individual interrupt sources. Temperature Configuration Register: The configuration of the temperature interrupt is controlled by the lower three bits of this register. VID/Fan Divisor Register: The status of the VID0 to VID4 pins of the processor can be written to and read from these registers. Divisor values for fan speed measurement are also stored in this register. Value and Limit Registers: The results of analog voltage inputs, temperature, and fan speed measurements are stored in these registers, along with their limit values. Analog Output Register: The code controlling the analog output DAC is stored in this register. Chassis Intrusion Clear Register: A signal latched on the chassis intrusion pin can be cleared by writing to this register.
SERIAL BUS INTERFACE
The serial bus protocol operates as follows: 1. The master initiates data transfer by establishing a START condition, defined as a high-to-low transition on the serial data line SDA while the serial clock line, SCL, remains high. This indicates that an address/data stream will follow. All slave peripherals connected to the serial bus respond to the START condition, and shift in the next eight bits, consisting of a 7-bit address (MSB first) plus an R/W bit, which determines the direction of the data transfer, i.e., whether data will be written to or read from the slave device. The peripheral whose address corresponds to the transmitted address responds by pulling the data line low during the low period before the ninth clock pulse, known as the Acknowledge Bit. All other devices on the bus now remain idle while the selected device waits for data to be read from or written to it. If the R/W bit is a 0, the master will write to the slave device. If the R/W bit is a 1, the master will read from the slave device. 2. Data is sent over the serial bus in sequences of nine clock pulses, eight bits of data followed by an Acknowledge Bit from the slave device. Transitions on the data line must occur during the low period of the clock signal and remain stable during the high period, as a low-to-high transition when the clock is high may be interpreted as a STOP signal. The number of data bytes that can be transmitted over the serial bus in a single Read or Write operation is limited only by what the master and slave devices can handle. 3. When all data bytes have been read or written, stop conditions are established. In Write mode, the master will pull the data line high during the tenth clock pulse to assert a STOP condition. In Read mode, the master device will override the Acknowledge Bit by pulling the data line high during the low period before the ninth clock pulse. This is known as No Acknowledge. The master will then take the data line low during the low period before the tenth clock pulse, then high during the tenth clock pulse to assert a STOP condition. Any number of bytes of data may be transferred over the serial bus in one operation, but it is not possible to mix read and write in one operation because the type of operation is determined at the beginning and cannot subsequently be changed without starting a new operation. In the case of the ADM1024, write operations contain either one or two bytes, and read operations contain one byte and perform the following functions. To write data to one of the device data registers or read data from it, the Address Pointer Register must be set so that the correct data register is addressed, then data can be written into that register or read from it. The first byte of a write operation always contains an address that is stored in the Address Pointer Register. If data is to be written to the device, the write operation contains a second data byte that is written to the register
Control of the ADM1024 is carried out via the serial bus. The ADM1024 is connected to this bus as a slave device, under the control of a master device, e.g., ICH. The ADM1024 has a 7-bit serial bus address. When the device is powered up, it will do so with a default serial bus address. The five MSBs of the address are set to 01011, and the two LSBs are determined by the logical states of Pin 1 (NTEST OUT/ADD). This is a three-state input that can be grounded, connected to VCC, or left open-circuit to give three different addresses.
Table I. ADD Pin Truth Table
ADD Pin GND No Connect VCC
A1 1 0 0
A0 0 0 1
If ADD is left open-circuit, the default address will be 0101100. ADD is sampled only at power-up, so any changes made while power is on will have no immediate effect. The facility to make hardwired changes to A1 and A0 allows the user to avoid conflicts with other devices sharing the same serial bus, for example, if more than one ADM1024 is used in a system.
-8-
REV. B
ADM1024
selected by the Address Pointer Register. This is illustrated in Figure 2a. The device address is sent over the bus followed by R/W set to 0. This is followed by two data bytes. The first data byte is the address of the internal data register to be written to, which is stored in the Address Pointer Register. The second data byte is the data to be written to the internal data register. When reading data from a register, there are two possibilities: 1. If the ADM1024's Address Pointer Register value is unknown or not the desired value, it is first necessary to set it to the correct value before data can be read from the desired data register. This is done by performing a write to the ADM1024 as before, but only the data byte containing the register address is sent, as data is not to be written to the register. This is shown in Figure 2b. A read operation is then performed consisting of the serial bus address, R/W bit set to 1, followed by the data byte read from the data register. This is shown in Figure 2c. 2. If the Address Pointer Register is known to be already at the desired address, data can be read from the corresponding data register without first writing to the Address Pointer Register, so Figure 2b can be omitted.
NOTES
2. In Figures 2a to 2c, the serial bus address is shown as the default value 01011(A1)(A0), where A1 and A0 are set by the three-state ADD pin.
MEASUREMENT INPUTS
The ADM1024 has nine external measurement pins that can be configured to perform various functions by programming the Channel Mode Register. Pins 13 and 14 are dedicated to temperature measurement, while Pins 15, 16, and 19 are dedicated analog input channels. Their function is unaffected by the Channel Mode Register. Pins 5 and 6 can be individually programmed as analog inputs, or as digital fan speed measurement inputs, by programming Bits 0 and 1 of the Channel Mode Register. Pins 17 and 18 can be configured as analog inputs or as inputs for external temperature-sensing diodes by programming Bit 2 of the Channel Mode Register. Bit 3 of the Channel Mode Register configures the internal VCC measurement range for either 3.3 V or 5 V. Bits 4 to 6 of the Channel Mode Register enable or disable Pins 22 to 24 when they are configured as interrupt inputs by setting Bit 7 of the Channel Mode Register. This function is controlled for Pins 20 and 21 by Bits 6 and 7 of Configuration Register 2. Bit 7 of the Channel Mode Register allows the processor core voltage ID bits (VID0 to VID4, Pins 24 to 20) to be reconfigured as interrupt inputs. A truth table for the Channel Mode Register is given in Table II.
1. Although it is possible to read a data byte from a data register without first writing to the Address Pointer Register, if the Address Pointer Register is already at the correct value it is not possible to write data to a register without writing to the Address Pointer Register because the first data byte of a write is always written to the Address Pointer Register.
REV. B
-9-
ADM1024
1 SCL 9 1 9
SDA START BY MASTER
0
1
0
1
1
A1
A0
R/W ACK. BY ADM1024
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY ADM1024
FRAME 1 SERIAL BUS ADDRESS BYTE 1 SCL (CONTINUED)
FRAME 2 ADDRESS POINTER REGISTER BYTE 9
SDA (CONTINUED)
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY STOP BY ADM1024 MASTER
FRAME 3 DATA BYTE
Figure 2a. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1 SCL 9 1 9
SDA START BY MASTER
0
1
0
1
1
A1
A0
R/W ACK. BY ADM1024
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY ADM1024 STOP BY MASTER
FRAME 1 SERIAL BUS ADDRESS BYTE
FRAME 2 ADDRESS POINTER REGISTER BYTE
Figure 2b. Writing to the Address Pointer Register Only
1 SCL 9 1 9
SDA START BY MASTER
0
1
0
1
1
A1
A0
R/W ACK. BY ADM1024
D7
D6
D5
D4
D3
D2
D1
D0 STOP BY NO ACK. BY MASTER MASTER
FRAME 1 SERIAL BUS ADDRESS BYTE
FRAME 2 DATA BYTE FROM ADM1024
Figure 2c. Reading Data from a Previously Selected Register
-10-
REV. B
ADM1024
Table II. Channel Mode Register
Channel Mode Register Bit 0 1 2 3 4 5 6 7
Power-On Default = 0000 0000
Controls Pin(s) 5 6 17, 18 Int. VCC Meas. 24 23 22 20-24
Function 0 = FAN1, 1 = AIN1 0 = FAN2, 1 = AIN2 0 = 2.5 V, VCCP2, 1 = D2-, D2+ 0 = 3.3 V, 1 = 5 V 0 = VID0, 1 = IRQ0 0 = VID1, 1 = IRQ1 0 = VID2, 1 = IRQ2 0 = VID0 to VID4, 1 = Interrupt Inputs
Table III. A/D Output Code vs. VIN Input Voltage +12 VIN <0.062 0.062-0.125 0.125-0.188 0.188-0.250 0.250-0.313 0.313-0.375 0.375-0.438 0.438-0.500 0.500-0.563 +5 VIN <0.026 0.026-0.052 0.052-0.078 0.078-0.104 0.104-0.130 0.130-0.156 0.156-0.182 0.182-0.208 0.208-0.234 VCC (3.3 V) <0.0172 0.017-0.034 0.034-0.052 0.052-0.069 0.069-0.086 0.086-0.103 0.103-0.120 0.120-0.138 0.138-0.155 VCC (5 V) <0.026 0.026-0.052 0.052-0.078 0.078-0.104 0.104-0.130 0.130-0.156 0.156-0.182 0.182-0.208 0.208-0.234 +2.5 VIN <0.013 0.013-0.026 0.026-0.039 0.039-0.052 0.052-0.065 0.065-0.078 0.078-0.091 0.091-0.104 0.104-0.117 * * * 0.833-0.846 * * * 1.667-1.680 * * * 2.500-2.513 * * * 3.190-3.203 3.203-3.216 3.216-3.229 3.229-3.242 3.242-3.255 3.255-3.268 3.268-3.281 3.281-3.294 3.294-3.307 3.307-3.320 >3.320 +VCCP1/2 <0.014 0.014-0.028 0.028-0.042 0.042-0.056 0.056-0.070 0.070-0.084 0.084-0.098 0.098-0.112 0.112-0.126 AIN(1/2) <0.010 0.010-0.019 0.019-0.029 0.029-0.039 0.039-0.049 0.049-0.058 0.058-0.068 0.068-0.078 0.078-0.087 A/D Output Decimal 0 1 2 3 4 5 6 7 8 Binary 00000000 00000001 00000010 00000011 00000100 00000101 00000110 00000111 00001000
4.000-4.063
1.666-1.692
1.100-1.117
1.666-1.692
0.900-0.914
0.625-0.635
64 (1/4-Scale)
01000000
8.000-8.063
3.330-3.560
2.200-2.217
3.330-3.560
1.800-1.814
1.250-1.260
128 (1/2-Scale) 10000000
12.000-12.063 5.000-5.026
3.300-3.317
5.000-5.026
2.700-2.714
1.875-1.885
192 (3/4-Scale) 11000000
15.312-15.375 15.375-15.437 15.437-15.500 15.500-15.563 15.563-15.625 15.625-15.688 15.688-15.750 15.750-15.812 15.812-15.875 15.875-15.938 >15.938
6.380-6.406 6.406-6.432 6.432-6.458 6.458-6.484 6.484-6.510 6.510-6.536 6.536-6.562 6.562-6.588 6.588-6.615 6.615-6.640 >6.640
4.210-4.230 4.230-4.245 4.245-4.263 4.263-4.280 4.280-4.300 4.300-4.314 4.314-4.331 4.331-4.348 4.348-4.366 4.366-4.383 >4.383
6.380-6.406 6.406-6.432 6.432-6.458 6.458-6.484 6.484-6.510 6.510-6.536 6.536-6.562 6.562-6.588 6.588-6.615 6.615-6.640 >6.640
3.445-3.459 3.459-3.473 3.473-3.487 3.487-3.501 3.501-3.515 3.515-3.529 3.529-3.543 3.543-3.558 3.558-3.572 3.572-3.586 >3.586
2.392-2.402 2.402-2.412 2.412-2.422 2.422-2.431 2.431-2.441 2.441-2.451 2.451-2.460 2.460-2.470 2.470-2.480 2.480-2.490 >2.490
245 246 247 248 249 250 251 252 253 254 255
11110101 11110110 11110111 11111000 11111001 11111010 11111011 11111100 11111101 11111110 11111111
REV. B
-11-
ADM1024
ANALOG-TO-DIGITAL CONVERTER
These inputs are multiplexed into the on-chip, successive approximation, analog-to-digital converter (ADC). This has a resolution of eight bits. The basic input range is 0 V to 2.5 V, which is the input range of AIN1 and AIN2, but five of the inputs have built-in attenuators to allow measurement of 2.5 V, 5 V, 12 V, and the processor core voltages VCCP1 and VCCP2 without any external components. To allow for the tolerance of these supply voltages, the ADC produces an output of 3/4 full scale (decimal 192) for the nominal input voltage, and so has adequate headroom to cope with overvoltages. Table III shows the input ranges of the analog inputs and output codes of the ADC. When the ADC is running, it samples and converts an input every 748 s, except for the external temperature (D1 and D2) inputs. These have special input signal conditioning and are averaged over 16 conversions to reduce noise, and a measurement on one of these inputs takes nominally 9.6 ms.
INPUT CIRCUITS
VIN
R1
AIN(1-2) R2
Figure 4. Scaling AIN(1-2)
V R1 ( FS - 2.5) = R2 2.5
Negative and bipolar input ranges can be accommodated by using a positive reference voltage to offset the input voltage range so it is always positive. To measure a negative input voltage, an attenuator can be used as shown in Figure 5.
+VOS R2
The internal structure for the analog inputs is shown in Figure 3. Each input circuit consists of an input protection diode, an attenuator, plus a capacitor to form a first-order low-pass filter that gives the input immunity to high frequency noise.
80k AIN1-AIN2 10pF 122.2k +12VIN 22.7k 91.6k +5VIN 55.2k +2.5VIN (SEE TEXT) 36.7k 111.2k +VCCP1/ VCCP2 42.7k 97.3k 50pF 25pF 25pF MUX 35pF
VIN
R1 AIN(1-2)
Figure 5. Scaling and Offsetting AIN(1-2) for Negative Inputs
R1 |VFS - | = R2 VOS
This is a simple and cheap solution, but the following point should be noted. Since the input signal is offset but not inverted, the input range is transposed. An increase in the magnitude of the -12 V supply (going more negative) will cause the input voltage to fall and give a lower output code from the ADC. Conversely, a decrease in the magnitude of the -12 V supply will cause the ADC code to increase. The maximum negative voltage corresponds to zero output from the ADC. This means that the upper and lower limits will be transposed. Bipolar input ranges can easily be accommodated. By making R1 equal to R2 and VOS = 2.5 V, the input range is 2.5 V. Other input ranges can be accommodated by adding a third resistor to set the positive full-scale input voltage.
+VOS
Figure 3. Structure of Analog Inputs
2.5 V INPUT PRECAUTIONS
R2 VIN R1
When using the 2.5 V input, the following precautions should be noted. There is a parasitic diode between Pin 18 and VCC due to the presence of a PMOS current source (which is used when Pin 18 is configured as a temperature input). This will become forward biased if Pin 18 is more than 0.3 V above VCC. Therefore, VCC should never be powered off with a 2.5 V input connected.
SETTING OTHER INPUT RANGES
AIN(1-2) R3
Figure 6. Scaling and Offsetting AIN(1-2) for Bipolar Inputs
R1 |VFS - | = R2 R2
AIN1 and AIN2 can easily be scaled to voltages other than 2.5 V. If the input voltage range is zero to some positive voltage, all that is required is an input attenuator, as shown in Figure 4.
(R3 has no effect as the input voltage at the device pin is zero when VIN = minus full scale.)
V R1 ( FS + - 2.5) = R3 2.5
-12-
REV. B
ADM1024
(R2 has no effect as the input voltage at the device pin is 2.5 V when VIN = plus full scale). Offset voltages other than 2.5 V can be used, but the calculation becomes more complicated.
TEMPERATURE MEASUREMENT SYSTEM Internal Temperature Measurement
D+ REMOTE SENSING TRANSISTOR VDD I N I IBIAS LOW-PASS FILTER fC = 65kHz VOUT+ TO ADC VOUT-
The ADM1024 contains an on-chip band gap temperature sensor, whose output is digitized by the on-chip ADC. The temperature data is stored in the Temperature Value Register (address 27h) and the LSB from Bits 6 and 7 of the Temperature Configuration Register (address 4Bh). As both positive and negative temperatures can be measured, the temperature data is stored in twos complement format, as shown in Table IV. Theoretically, the temperature sensor and ADC can measure temperatures from -128C to +127C with a resolution of 1C, although temperatures below -40C and above +125C are outside the operating temperature range of the device.
External Temperature Measurement
D-
BIAS DIODE
Figure 7. Signal Conditioning for External Diode Temperature Sensors
If a discrete transistor is used, the collector will not be grounded and should be linked to the base. If a PNP transistor is used, the base is connected to the D- input and the emitter to the D+ input. If an NPN transistor is used, the emitter is connected to the D- input and the base to the D+ input. To prevent ground noise from interfering with the measurement, the more negative terminal of the sensor is not referenced to ground, but is biased above ground by an internal diode at the D- input. As the sensor is operating in a noisy environment, C1 is provided as a noise filter. See the section on layout considerations for more information on C1. To measure VBE, the sensor is switched between operating currents of I and N x I. The resulting waveform is passed through a 65 kHz low-pass filter to remove noise, then to a chopper stabilized amplifier that performs the functions of amplification and rectification of the waveform to produce a dc voltage proportional to VBE. This voltage is measured by the ADC to give a temperature output in 8-bit twos complement format. To further reduce the effects of noise, digital filtering is performed by averaging the results of 16 measurement cycles. An external temperature measurement takes nominally 9.6 ms. The results of external temperature measurements are stored in 8-bit, twos complement format, as illustrated in Table IV.
Table IV. Temperature Data Format
The ADM1024 can measure the temperature of two external diode sensors or diode connected transistors, connected to Pins 13 and 14 or 17 and 18. Pins 13 and 14 are a dedicated temperature input channel. Pins 17 and 18 can be configured to measure a diode sensor by setting Bit 2 of the Channel Mode Register to 1. The forward voltage of a diode or diode connected transistor, operated at a constant current, exhibits a negative temperature coefficient of about -2 mV/C. Unfortunately, the absolute value of VBE varies from device to device, and individual calibration is required to null this out, so the technique is unsuitable for mass-production. The technique used in the ADM1024 is to measure the change in VBE when the device is operated at two different currents. This is given by: VBE = KT /q x ln(N ) where: K is Boltzmann's constant. q is the charge on the carrier. T is the absolute temperature in Kelvins. N is the ratio of the two currents. Figure 7 shows the input signal conditioning used to measure the output of an external temperature sensor. This figure shows the external sensor as a substrate transistor provided for temperature monitoring on some microprocessors, but it could equally well be a discrete transistor.
Temperature -128C -125C -100C -75C -50C -25C 0C +0.5C +10C +25C +50C +75C +100C +125C +127C
Digital Output 1000 0000 1000 0011 1001 1100 1011 0101 1100 1110 1110 0111 0000 0000 0000 0000 0000 1010 0001 1001 0011 0010 0100 1011 0110 0100 0111 1101 0111 1111
REV. B
-13-
ADM1024
LAYOUT CONSIDERATIONS LIMIT VALUES
Digital boards can be electrically noisy environments, and care must be taken to protect the analog inputs from noise, particularly when measuring the very small voltages from a remote diode sensor. The following precautions should be taken: 1. Place the ADM1024 as close as possible to the remote sensing diode. Provided that the worst noise sources such as clock generators, data/address buses, and CRTs are avoided, this distance can be 4 inches to 8 inches. 2. Route the D+ and D- tracks close together, in parallel, with grounded guard tracks on each side. Provide a ground plane under the tracks if possible. 3. Use wide tracks to minimize inductance and reduce noise pickup. A 10 mil track minimum width and spacing is recommended.
GND 10MIL 10MIL D+ 10MIL 10MIL D- 10MIL 10MIL GND 10MIL
Limit values for analog measurements are stored in the appropriate limit registers. In the case of voltage measurements, high and low limits can be stored so that an interrupt request will be generated if the measured value goes above or below acceptable values. In the case of temperature, a Hot Temperature or High Limit can be programmed, and a Hot Temperature Hysteresis or Low Limit, which will usually be some degrees lower. This can be useful as it allows the system to be shut down when the hot limit is exceeded, and restarted automatically when it has cooled down to a safe temperature.
MONITORING CYCLE TIME
The monitoring cycle begins when a 1 is written to the Start Bit (Bit 0), and a 0 to the INT_Clear Bit (Bit 3) of the Configuration Register. INT_Enable (Bit 1) should be set to 1 to enable the INT output. The ADC measures each analog input in turn; as each measurement is completed, the result is automatically stored in the appropriate value register. This "round-robin" monitoring cycle continues until it is disabled by writing a 0 to Bit 0 of the Configuration Register. As the ADC will normally be left to free-run in this manner, the time taken to monitor all the analog inputs will normally not be of interest, as the most recently measured value of any input can be read out at any time. For applications where the monitoring cycle time is important, it can be calculated as follows:
m x t1 + n x t2
Figure 8. Arrangement of Signal Tracks
4. Try to minimize the number of copper/solder joints, which can cause thermocouple effects. Where copper/solder joints are used, make sure that they are in both the D+ and D- path and at the same temperature. Thermocouple effects should not be a major problem as 1C corresponds to about 240 V, and thermocouple voltages are about 3 V/C of temperature difference. Unless there are two thermocouples with a big temperature differential between them, thermocouple voltages should be much less than 200 mV. 5. Place 0.1 F bypass and 2200 pF input filter capacitors close to the ADM1024. 6. If the distance to the remote sensor is more than 8 inches, the use of twisted pair cable is recommended. This will work up to about 6 feet to 12 feet. 7. For really long distances (up to 100 feet) use shielded twisted pair such as Belden #8451 microphone cable. Connect the twisted pair to D+ and D- and the shield to GND close to the ADM1024. Leave the remote end of the shield unconnected to avoid ground loops. Because the measurement technique uses switched current sources, excessive cable and/or filter capacitance can affect the measurement. When using long cables, the filter capacitor may be reduced or removed. Cable resistance can also introduce errors. A 1 series resistance introduces about 0.5C error.
where: m is the number of inputs configured as analog inputs, plus the internal VCC measurement and internal temperature sensor. t1 is the time taken for an analog input conversion, nominally 6.044 ms. n is the number of inputs configured as external temperature inputs. t2 is the time taken for a temperature conversion, nominally 33.24 ms. This rapid sampling of the analog inputs ensures a quick response in the event of any input going out of limits, unlike other monitoring chips that employ slower ADCs.
FAN MONITORING CYCLE TIME
When a monitoring cycle is started, monitoring of the fan speed inputs begins at the same time as monitoring of the analog inputs. However, the two monitoring cycles are not synchronized in any way. The monitoring cycle time for the fan inputs is dependent on fan speed and is much slower than for the analog inputs. For more details, see the Fan Speed Measurement section.
-14-
REV. B
ADM1024
INPUT SAFETY
Scaling of the analog inputs is performed on chip, so external attenuators are normally not required. However, since the power supply voltages will appear directly at the pins, it is advisable to add small external resistors in series with the supply traces to the chip to prevent damaging the traces or power supplies should an accidental short such as a probe connect two power supplies together.
As the resistors will form part of the input attenuators, they will affect the accuracy of the analog measurement if their value is too high. The analog input channels are calibrated assuming an external series resistor of 500 , and the accuracy will remain within specification for any value from 0 k to 1 k, so a standard 510 resistor is suitable. The worst such accident would be connecting -12 V to +12 V-- a total of 24 V difference. With the series resistors, this would draw a maximum current of approximately 24 mA.
12V
12V AOUT
R1 100k
R2 100k Q3 IRF9620
R1 10k
Figure 9a. Fan Drive Circuit with Op Amp and Emitter-Follower
12V
AOUT
R1 10k
Figure 9b. Fan Drive Circuit with Op Amp and PNP Transistor
12V
AOUT
1/4 LM324
R1 10k
Figure 9c. Fan Driver Circuit with Op Amp and P-Channel MOSFET
REV. B
+
+
+
1/4 LM324 R2 36k
R3 3.9k AOUT Q1/Q2 MBT3904 DUAL R4 1k
Q1 2N2219A
Figure 9d. Discrete Fan Drive Circuit with P-Channel MOSFET, Single Supply
+12V
1/4 LM324
R4 1k R3 1k R2 39k
Q1 BD136 2SA968
R2 100k Q3 IRF9620 R3 39k R4 10k
AOUT
Q1/Q2 MBT3904 DUAL R1 4.7k -12V
Figure 9e. Discrete Fan Drive Circuit with P-Channel MOSFET, Dual Supply
12V
R3 100k Q1 IRF9620
R1 100k
R2 100k Q3 BC556 2N3906 Q4 BD132 TIP32A
R2 39k
R3 3.9k AOUT Q1/Q2 MBT3904 DUAL R5 100 R4 1k
Figure 9f. Discrete Fan Drive Circuit with Bipolar Output Dual Supply
-15-
ADM1024
ANALOG OUTPUT
The ADM1024 has a single analog output from an unsigned 8-bit DAC that produces 0 V to 2.5 V. The analog output register defaults to FF during power-on reset, which produces maximum fan speed. The analog output may be amplified and buffered with external circuitry such as an op amp and transistor to provide fan speed control. Suitable fan drive circuits are given in Figures 9a to 9f. When using any of these circuits, the following points should be noted: 1. All of these circuits will provide an output range from 0 V to almost 12 V, apart from Figure 9a which loses the baseemitter voltage drop of Q1 due to the emitter-follower configuration. 2. To amplify the 2.5 V range of the analog output up to 12 V, the gain of these circuits needs to be around 4.8. 3. Care must be taken when choosing the op amp to ensure that its input common-mode range and output voltage swing are suitable. 4. The op amp may be powered from the 12 V rail alone or from 12 V. If it is powered from 12 V, then the input common-mode range should include ground to accommodate the minimum output voltage of the DAC, and the output voltage should swing below 0.6 V to ensure that the transistor can be turned fully off. 5. If the op amp is powered from -12 V, precautions such as a clamp diode to ground may be needed to prevent the baseemitter junction of the output transistor being reverse-biased in the unlikely event that the output of the op amp should swing negative for any reason. 6. In all these circuits, the output transistor must have an ICMAX greater than the maximum fan current, and be capable of dissipating power due to the voltage dropped across it when the fan is not operating at full speed. 7. If the fan motor produces a large back EMF when switched off, it may be necessary to add clamp diodes to protect the output transistors in the event that the output goes very quickly from full scale to zero.
FAULT-TOLERANT FAN CONTROL
The temperature measured by the on-chip sensor exceeds 70C, which is hardware programmed into a read-only register at address 17h. or The temperature measured by either of the remote sensors exceeds 85C, which is hardware programmed into a read-only register at address 18h. Once the hardware override of the analog output is triggered, it will return to normal operation only after three consecutive measurements that are 5 degrees lower than each of the above limits. The analog output can also be forced to FFh by pulling the THERM pin (Pin 2) low. The limits in Registers 13h and 14h can be programmed by the user. Obviously, these limits should not exceed the hardware values in Registers 17h and 18h, as they would have no effect. The power-on default values of these registers are the same as the two hardware registers, 70C and 85C respectively, so there is no need to program them if these limits are acceptable. Once these registers have been programmed, or if the defaults are acceptable, the values in these registers can be locked by writing a 1 to Bits 1 and 2 of Configuration Register 2 (address 4Ah). This prevents any unauthorized tampering with the limits. These lock bits can only be written to 1 and can only be cleared by power-on reset or by taking the RESET pin low, so registers 13h and 14h cannot be written to again unless the device is powered off, then on.
LAYOUT AND GROUNDING
Analog inputs will provide best accuracy when referred to a clean ground. A separate, low impedance ground plane for analog ground, which provides a ground point for the voltage dividers and analog components, will provide best performance but is not mandatory. The power supply bypass, the parallel combination of 10 F (electrolytic or tantalum) and 0.1 F (ceramic) bypass capacitors connected between Pin 9 and ground, should also be located as close as possible to the ADM1024.
FAN INPUTS
The ADM1024 incorporates a fault-tolerant fan control capability that can override the setting of the analog output and force it to maximum to give full fan speed in the event of a critical overtemperature problem even if, for some reason, this has not been handled by the system software. There are four temperature set points that will force the analog output to FFh if any one of them is exceeded for three or more consecutive measurements. Two of these limits are programmable by the user and two are hardware limits intended as must-notexceed limits that cannot be changed. The analog output will be forced to FFh if: The temperature measured by the on-chip sensor exceeds the limit programmed into register address 13h. or The temperature measured by either of the remote sensors exceeds the limit programmed into address 14h. or
Pins 5 and 6 may be configured as analog inputs or fan speed inputs by programming Bits 0 and 1 of the Channel Mode Register. The power-on default for these bits is all zeros, which makes Pins 5 and 6 fan inputs. Signal conditioning in the ADM1024 accommodates the slow rise and fall times typical of fan tachometer outputs. The maximum input signal range is 0 to VCC. In the event that these inputs are supplied from fan outputs that exceed 0 V to 6.5 V, either resistive attenuation of the fan signal or diode clamping must be included to keep inputs within an acceptable range. Figures 10a to 10d show circuits for most common fan tachometer outputs. If the fan tachometer output has a resistive pull-up to VCC, it can be directly connected to the fan input, as shown in Figure 10a.
-16-
REV. B
ADM1024
12V VCC
12V VCC
PULL-UP 4.7k TYP TACH. OUTPUT
<1k
FAN1 OR FAN2 160k
R1* TACH. OUTPUT
FAN1 OR FAN2 R2* 160k
FAN SPEED COUNTER
FAN SPEED COUNTER
*SEE TEXT
Figure 10a. Fan with Tach. Pull-Up to +VCC
Figure 10d. Fan with Strong Tach. Pull-Up to >VCC or Totem-Pole Output, Attenuated with R1/R2
FAN SPEED MEASUREMENT
If the fan output has a resistive pull-up to 12 V (or other voltage greater than 6.5 V), the fan output can be clamped with a Zener diode, as shown in Figure 10b. The Zener voltage should be chosen so it is greater than VIH but less than 6.5 V, allowing for the voltage tolerance of the Zener. A value of between 3 V and 5 V is suitable.
12V VCC
PULL-UP 4.7k TYP TACH. OUTPUT
FAN1 OR FAN2 ZD1* ZENER 160k
The fan counter does not count the fan tachometer output pulses directly because the fan speed may be less than 1000 rpm and it would take several seconds to accumulate a reasonably large and accurate count. Instead, the period of the fan revolution is measured by gating an on-chip 22.5 kHz oscillator into the input of an 8-bit counter for two periods of the fan tachometer output, as shown in Figure 11; the accumulated count is actually proportional to the fan tachometer period and inversely proportional to the fan speed.
22.5kHz CLOCK CONFIG. REG. 1 BIT 0
FAN SPEED COUNTER
*CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8
VCC FAN1 INPUT FAN2 INPUT FAN1 MEASUREMENT PERIOD START OF MONITORING CYCLE FAN2 MEASUREMENT PERIOD
Figure 10b. Fan with Tach. Pull-Up to Voltage >6.5 V (e.g., 12 V ) Clamped with Zener Diode
If the fan has a strong pull-up (less than 1 k) to 12 V, or a totem-pole output, then a series resistor can be added to limit the Zener current, as shown in Figure 10c. Alternatively, a resistive attenuator may be used, as shown in Figure 10d. R1 and R2 should be chosen such that: 2V < VPULL -UP x R2 / (RPULL -UP + R1 + R2) < 5V The fan inputs have an input resistance of nominally 160 k to ground, so this should be taken into account when calculating resistor values. With a pull-up voltage of 12 V and pull-up resistor less than 1 k, suitable values for R1 and R2 would be 100 k and 47 k. This will give a high input voltage of 3.83 V.
12V VCC
Figure 11. Fan Speed Measurement
PULL-UP TYP. <1k OR TOTEM-POLE
R1 10k TACH. OUTPUT
FAN1 OR FAN2 ZD1* ZENER 160k
FAN SPEED COUNTER
The monitoring cycle begins when a one is written to the Start Bit (Bit 0), and a zero to the INT_Clear Bit (Bit 3) of the Configuration Register. INT_Enable (Bit 1) should be set to one to enable the INT output. The measurement begins on the rising edge of a fan tachometer pulse, and ends on the next-butone rising edge. The fans are monitored sequentially, so if only one fan is monitored the monitoring time is the time taken after the Start Bit for it to produce two complete tachometer cycles or for the counter to reach full scale, whichever occurs sooner. If more than one fan is monitored, the monitoring time depends on the speed of the fans and the timing relationship of their tachometer pulses. This is illustrated in Figure 12. Once the fan speeds have been measured, they will be stored in the Fan Speed Value Registers and the most recent value can be read at any time. The measurements will be updated as long as the monitoring cycle continues. To accommodate fans of different speed and/or different numbers of output pulses per revolution, a prescaler (divisor) of 1, 2, 4, or 8 may be added before the counter. The default value is 2, which gives a count of 153 for a fan running at 4400 rpm, producing two output pulses per revolution. The count is calculated by the equation:
*CHOOSE ZD1 VOLTAGE APPROXIMATELY. 0.8
VCC
Figure 10c. Fan with Strong Tach. Pull-Up to >VCC or Totem-Pole Output, Clamped with Zener and Resistor
Count = 22.5 x 103 x 60 / (rpm x Divisor )
REV. B -17-
(
)
ADM1024
For constant speed fans, fan failure is normally considered to have occurred when the speed drops below 70% of nominal, which would correspond to a count of 219. Full scale (255) would be reached if the fan speed fell to 60% of its nominal value. For temperature controlled variable speed fans, the situation will be different. Table V shows the relationship between fan speed and time per revolution at 60%, 70%, and 100% of nominal rpm for fan speeds of 1100, 2200, 4400, and 8800 rpm, and the divisor that would be used for each of these fans, based on two tachometer pulses per revolution.
Table V. Fan Speeds and Divisors FAN MANUFACTURERS
Manufacturers of cooling fans with tachometer outputs are listed below: NMB Tech 9730 Independence Ave. Chatsworth, California 91311 Phone: 818-341-3355; Fax: 818-341-8207 Model 2408NL 2410ML 3108NL 3110KL Frame Size 2.36 in sq. x 0.79 in (60 mm sq. x 20 mm) 2.36 in sq. x 0.98 in (60 mm sq. x 25 mm) 3.15 in sq. x 0.79 in (80 mm sq. x 20 mm) 3.15 in sq. x 0.98 in (80 mm sq. x 25 mm) Airflow CFM 9-16 14-25 25-42 25-40
Time Time per per Nominal Rev 70% Rev (70%) Divisor rpm (ms) rpm (ms) /1 /2 /4 /8 8800 4400 2200 1100 6.82 13.64 27.27 54.54 6160 3080 1540 770 9.74 19.48 38.96 77.92
Time per 60% Rev (60%) rpm (ms) 5280 2640 1320 660 11.36 22.73 45.44 90.90
Mechatronics Inc. P.O. Box 613 Preston, WA 98050 800-453-4569 Models--Various sizes available with tachometer output option. Sanyo Denki, America, Inc. 468 Amapola Avenue Torrance, CA 90501 310-783-5400 Models--109P Series
CHASSIS INTRUSION INPUT
FAN1 and FAN2 Divisors are programmed into Bits 4 to 7 of the VID0-3/Fan Divisor Register.
LIMIT VALUES
Fans in general will not overspeed if run from the correct voltage, so the failure condition of interest is underspeed due to electrical or mechanical failure. For this reason only, low speed limits are programmed into the limit registers for the fans. It should be noted that, since fan period rather than speed is being measured, a fan failure interrupt will occur when the measurement exceeds the limit value.
MONITORING CYCLE TIME
The Chassis Intrusion input is an active high input/open-drain output intended for detection and signalling of unauthorized tampering with the system. An external circuit powered from the system's CMOS backup battery is used to detect and latch a chassis intrusion event, whether or not the system is powered up. Once a chassis intrusion has been detected and latched, the CI input will generate an interrupt when the system is powered up. The actual detection of chassis intrusion is performed by an external circuit that will, for example, detect when the cover has been removed. A wide variety of techniques may be used for the detection, for example: * * * * Microswitch that opens or closes when the cover is removed. Reed switch operated by magnet fixed to the cover. Hall-effect switch operated by magnet fixed to the cover. Phototransistor that detects light when the cover is removed.
The monitoring cycle time depends on the fan speed and number of tachometer output pulses per revolution. Two complete periods of the fan tachometer output (three rising edges) are required for each fan measurement. Therefore, if the start of a fan measurement just misses a rising edge, the measurement can take almost three tachometer periods. In order to read a valid result from the fan value registers, the total monitoring time allowed after starting the monitoring cycle should, therefore, be three tachometer periods of FAN1 plus three tachometer periods of FAN2 at the lowest normal fan speed. Although the fan monitoring cycle and the analog input monitoring cycle are started together, they are not synchronized in any other way.
The chassis intrusion interrupt will remain asserted until the external detection circuit is reset. This can be achieved by setting Bit 7 of the Chassis Intrusion Clear Register to one, which will cause the CI pin to be pulled low for at least 20 ms. This register bit is self-clearing. The chassis intrusion circuit should be designed so that it can be reset by pulling its output low. A suitable chassis intrusion circuit using a phototransistor is shown in Figure 12. Light falling on the phototransistor when the PC cover is removed will cause it to turn on and pull up the input of N1, thus setting the latch N3/N4. After the cover is replaced, a low reset on the CI output will pull down the input of N4, resetting the latch.
-18-
REV. B
ADM1024
1N914 MRD901 1N914 5V CMOS BACKUP BATTERY
74HC132
100k N1 N3 CI
output is inverted by Q1 to make it compatible with the CI input. Q1 can be almost any small-signal NPN transistor, or a TTL or CMOS inverter gate may be used if one is available. See the AD22105 data sheet for information on selecting RSET.
VCC R1 10k
470k
AD22105
10k N2 N4
CI Q1
RSET
TEMPERATURE SENSOR
Figure 12. Chassis Intrusion Detector and Latch
Figure 13. Using the CI Input with a Temperature Sensor
The Chassis Intrusion input can also be used for other types of alarm input. Figure 13 shows a temperature alarm circuit using an AD22105 temperature switch sensor. This produces a low going output when the preset temperature is exceeded, so the
Note: The chassis intrusion input does not have a protective clamp diode to VCC, as this could pull down the chassis intrusion latch and reset it when the ADM1024 is powered down.
VID0/IRQ0 VID1/IRQ1 VID2/IRQ2 VID3/IRQ3 VID4/IRQ4 VID0-VID4 REGISTERS
4 5 CHANNEL MODE REGISTER 6
7
6 CONFIGURATION REGISTER 2 7 2.5V/EXT. TEMP 2 VCCP1 VCC +5VIN HIGH LIMIT HIGH FROM AND VALUE LOW VALUE AND LIMIT LIMIT REGISTERS COMPARATORS LOW LIMIT INT. TEMP EXT. TEMP1 FAN1/AIN1 FAN2/AIN2 DATA DEMULTIPLEXER +12VIN VCCP2 RESERVED RESERVED CI THERM D1 FAULT D2 FAULT
0 1 2 INTERRUPT 3 STATUS 4 REGISTER 1 5 6 7 0 1 2 INTERRUPT 3 STATUS 4 REGISTER 2 5 6 7 MASK GATING STATUS BIT MASK BIT 11
1 = OUT OF LIMIT
INT
INT ENABLE
INT CLEAR
CONFIGURATION REGISTER 1 THERM CLEAR
16 MASK BITS MASKING DATA FROM BUS INTERRUPT MASK REGISTERS 1 AND 2 (SAME BIT ORDER AS STATUS REGISTERS) THERM
THERM
Figure 14. Interrupt Register Structure
REV. B
-19-
ADM1024
THE ADM1024 INTERRUPT STRUCTURE TEMPERATURE INTERRUPT MODES
The Interrupt Structure of the ADM1024 is shown in Figure 14. As each measurement value is obtained and stored in the appropriate value register, the value and the limits from the corresponding limit registers are fed to the high and low limit comparators. The result of each comparison (1 = out of limit, 0 = in limit) is routed to the corresponding bit input of the Interrupt Status Registers via a data demultiplexer and used to set that bit high or low as appropriate. The Interrupt Mask Registers have bits corresponding to each of the Interrupt Status Register Bits. Setting an Interrupt Mask Bit high forces the corresponding Status Bit output low, while setting an Interrupt Mask Bit low allows the corresponding Status Bit to be asserted. After masking, the status bits are all OR'd together to produce the INT output, which will pull low if any unmasked status bit goes high, i.e., when any measured value goes out of limit. The ADM1024 also has a dedicated output for temperature interrupts only, the THERM input/output Pin 2. The function of this is described later. The INT output is enabled when Bit 1 of Configuration Register 1 (INT_Enable) is high, and Bit 3 (INT_Clear) is low. The INT pin has an internal, 100 k pull-up resistor.
VID/IRQ INPUTS
The ADM1024 has two distinct methods of producing interrupts for out-of-limit temperature measurements from the internal or external sensors. Temperature errors can generate an interrupt on the INT pin along with other interrupts, but there is also a separate THERM pin that generates an interrupt only for temperature errors. Operation of the INT output for temperature interrupts is illustrated in Figure 15. Assuming that the temperature starts off within the programmed limits and that temperature interrupt sources are not masked, INT will go low if the temperature measured by any of the internal or external sensors exceeds the programmed high temperature limit for that sensor, or the hardware limits in register 13h, 14h, 17h, or 18h.
100 C 90 C 80 C 70 C 60 C 50 C 40 C * * LOW LIMIT TEMP * * * * HIGH LIMIT
The processor voltage ID inputs VID0 to VID4 can be reconfigured as interrupt inputs by setting Bit 7 of the Channel Mode Register (address 16h). In this mode they operate as leveltriggered interrupt inputs, with VID0/IRQ0 to VID2/IRQ2 being active low and VID3/IRQ3 and VID4/IRQ4 being active high. The individual interrupt inputs can be enabled or masked by setting or clearing Bits 4 to 6 of the Channel Mode Register and Bits 6 and 7 of Configuration Register 2 (address 4Ah). These interrupt inputs are not latched in the ADM1024, so they do not require clearing as do bits in the Status Registers. However, the external interrupt source should be cleared once the interrupt has been serviced, or the interrupt request will be reasserted.
INTERRUPT CLEARING
INT ACPI CONTROL METHODS CLEAR EVENT *ACPI AND DEFAULT CONTROL METHODS ADJUST TEMPERATURE LIMIT VALUES
Figure 15. Operation of INT for Temperature Interrupts
Once the interrupt has been cleared, it will not be reasserted even if the temperature remains above the high limit(s). However, INT will be reasserted if: a. the temperature falls below the low limit for the sensor or b. the high limit(s) is/are reprogrammed to a new value, and the temperature then rises above the new high limit on the next monitoring cycle or c. the THERM pin is pulled low externally, which sets Bit 5 of Interrupt Status Register 2 or d. an interrupt is generated by another source. Similarly, should the temperature measured by a sensor start off within limits then fall below the low limit, INT will be asserted. Once cleared, it will not be reasserted unless: a. the temperature rises above the high limit or b. the low limit(s) is/are reprogrammed, and the temperature then falls below the new low limit or c. the THERM pin is pulled low externally, which sets Bit 5 of Interrupt Status Register 2 or d. an interrupt is generated by another source.
Reading an Interrupt Status Register will output the contents of the Register, then clear it. It will remain cleared until the monitoring cycle updates it, so the next read operation should not be performed on the register until this has happened, or the result will be invalid. The time taken for a complete monitoring cycle is mainly dependent on the time taken to measure the fan speeds, as described earlier. The INT output is cleared with the INT_Clear bit, which is Bit 3 of the Configuration Register, without affecting the contents of the Interrupt (INT) Status Registers.
INTERRUPT STATUS MIRROR REGISTERS
Whenever a bit in one of the Interrupt Status Registers is updated, the same bit is written to duplicate registers at addresses 4Ch and 42h. These registers allow a second management system to access the status data without worrying about clearing the data. The data in these registers is for reading only and has no effect on the interrupt output.
-20-
REV. B
ADM1024
THERM INPUT/OUTPUT
The Thermal Management Input/Output (THERM) is a logic input/output with an internal, 100 k pull-up resistor, that provides a separate output for temperature interrupts only. It is enabled by setting Bit 2 of Configuration Register 1. The THERM output has two operating modes that can be programmed by Bit 3 of Configuration Register 2 (address 4Ah). With this bit set to the default value of 0, the THERM output operates in "Default" interrupt mode. With this bit set to 1, the THERM output operates in "ACPI" mode. Thermal interrupts can still be generated at the INT output while THERM is enabled, but if these are not required they can be masked by writing a 1 to Bit 0 of Configuration Register 2 (address 4Ah). The THERM pin can also function as a logic input for an external sensor, for example, a temperature sensor such as the ADM22105 used in Figure 16b. If THERM is taken low by an external source, the analog output will be forced to FFh to switch a controlled fan to maximum speed. This also generates an INT output as previously described.
DEFAULT MODE
Reading Status Register 1 will not clear THERM in this case, because errors caused by exceeding the hardware temperature limits are stored in a separate register that is not cleared by reading the status register. In this case, THERM can only be cleared by setting Bit 0 of Configuration Register 2. THERM will be cleared automatically if the temperature falls at least 5 degrees below the limit for three consecutive measurements.
ACPI MODE
In ACPI mode, THERM responds only to the hardware temperature limits at addresses 13h, 14h, 17h, and 18h, not to the software programmed limits.
HARDWARE TRIP POINT 5 TEMP
THERM PROGRAMMED VALUE EXT THERM INPUT
In Default mode, the THERM output operates like a thermostat with hysteresis. THERM will go low and Bit 5 of Interrupt Status Register 2 will be set, if the temperature measured by any of the sensors exceeds the high limit programmed for that sensor. It will remain asserted until reset by reading Interrupt Status Register 2, by setting Bit 6 of Configuration Register 1, or when the temperature falls below the low limit programmed for that sensor.
ANALOG OUTPUT
FFh
FFh
Figure 16b. THERM Output in ACPI Mode
TEMP HIGH LIMIT
THERM will go low if either the internal or external hardware temperature limit is exceeded for three consecutive measurements. It will remain low until the temperature falls at least 5 degrees below the limit for three consecutive measurements. While THERM is low, the analog output will go to FFh to boost a controlled fan to full speed.
RESET INPUT/OUTPUT
TEMP TEMP LOW LIMIT THERM CLEARED BY CLEARED BY PROGRAMMED READ OR TEMP FALLING VALUE THERM CLEAR BELOW LOW LIMIT FFH ANALOG OUTPUT EXT THERM INPUT
Figure 16a. INT or THERM Output in Default Mode
If THERM is cleared by reading the status register, it will be reasserted after the next temperature reading and comparison if it remains above the high limit. If THERM is cleared by setting Bit 6 of Configuration Register 1, it cannot be reasserted until this bit is cleared. THERM will also be asserted if one of the hardware temperature limits at addresses 13h, 14h, 17h, or 18h is exceeded for three consecutive measurements. When this happens, the analog output will be forced to FFh to boost a controlled cooling fan to full speed.
RESET (Pin 12) is an I/O pin that can function as an open-drain output, providing a low going 20 ms output pulse when Bit 4 of the Configuration Register is set to 1, provided the reset function has first been enabled by setting Bit 7 of Interrupt Mask Registers 2 to 1. The bit is automatically cleared when the reset pulse is output. Pin 11 can also function as a RESET input by pulling this pin low to reset the internal registers of the ADM1024 to default values. Only those registers that have power-on default values as listed in Table VII are affected by this function. The DAC, Value, and Limit Registers are not affected.
NAND TESTS
A NAND gate is provided in the ADM1024 for Automated Test Equipment (ATE) board level connectivity testing. The device is placed into NAND Test Mode by powering up with Pin 11 held high. This pin is automatically sampled after power-up; if it is connected high, then the NAND test mode is invoked. In NAND test mode, all digital inputs may be tested as illustrated below. NTEST_OUT/ADD will become the NAND test output pin. To perform a NAND tree test, all pins included in the NAND tree should first be driven high. Each pin can then be toggled and a resulting toggle can be observed on NTEST_OUT/ADD.
REV. B
-21-
ADM1024
Allow for a typical propagation delay of 500 ns. The structure of the NAND tree is shown in Figure 17.
POWER-ON RESET C NTEST IN/AOUT SDA SCL FAN1 FAN2 VID0 VID1 VID2 VID3 VID4 D LATCH Q
Configuration Register initialization is accomplished by setting Bit 7 of the Configuration Register high. This bit automatically clears after being set.
Using the Configuration Registers
ENABLE NTEST OUT/ADD
Control of the ADM1024 is provided through two configuration registers. The ADC is stopped upon power-up, and the INT_Clear signal is asserted, clearing the INT output. The Configuration Registers are used to start and stop the ADM1024; enable or disable interrupt outputs and modes, and provide the initialization function described above. Bit 0 of Configuration Register 1 controls the monitoring loop of the ADM1024. Setting Bit 0 low stops the monitoring loop and puts the ADM1024 into a low power mode thereby reducing power consumption. Serial bus communication is still possible with any register in the ADM1024 while in low power mode. Setting Bit 0 high starts the monitoring loop. Bit 1 of Configuration Register 1 enables or disables the INT Interrupt output. Setting Bit 1 high enables the INT output; setting Bit 1 low disables the output. Bit 2 of Configuration Register 1 enables or disables the THERM output. Setting Bit 1 high enables the INT output; setting Bit 1 low disables the output. Bit 3 of Configuration Register 1 is used to clear the INT interrupt output when set high. The ADM1024 monitoring function will stop until Bit 3 is set low. Interrupt Status register contents will not be affected. Bit 4 of Configuration Register 1 causes a low going 45 ms (typ) pulse at the RESET pin (Pin 12). Bit 6 of Configuration Register 1 is used to clear an interrupt at the THERM output when it is set to 1. Bit 7 of Configuration Register 1 is used to start a Configuration Register Initialization when it is set to 1. Bit 0 of Configuration Register 2 is used to mask temperature interrupts at the INT output when it is set to 1. The THERM output is unaffected by this bit. Bits 1 and 2 of Configuration Register 2 lock the values stored in the Local and Remote Fan Control Registers at addresses 13h and 14h. The values in these registers cannot be changed until a power-on reset is performed. Bit 3 of Configuration Register 2 selects the THERM interrupt mode. The default value of 0 selects one-time mode. Setting this bit to 1 selects ACPI mode.
Starting Conversion
Figure 17. NAND Tree
Note that NTEST_OUT/ADD is a dual function line and if both functions are required, then this line should not be hardwired directly to VCC/GND. Instead it should be connected via a 5 k resistor. Note: If any of the inputs shown in Figure 17 are unused, they should not be connected directly to ground, but via a resistor such as 10 k. This will allow the ATE (Automatic Test Equipment) to drive every input high so that the NAND tree test can be carried out properly.
USING THE ADM1024 Power-On Reset
When power is first applied, the ADM1024 performs a "poweron reset" on several of its registers. Registers whose power-on values are not shown have power-on conditions that are indeterminate (this includes the Value and Limit Registers). The ADC is inactive. In most applications, usually the first action after power-on would be to write limits into the Limit Registers. Power-on reset clears or initializes the following registers (the initialized values are shown in Table VII): * * * * * * * * * * * Configuration Registers 1 and 2 Channel Mode Register Interrupt (INT) Status Registers 1 and 2 Interrupt (INT) Status Mirror Registers 1 and 2 Interrupt (INT) Mask Registers 1 and 2 VID/Fan Divisor Register VID4 Register Chassis Intrusion Clear Register Test Register Analog Output Register Hardware Trip Registers
Initialization
Configuration Register initialization performs a similar, but not identical, function to power-on reset. The Test Register and Analog Output Register are not initialized.
The monitoring function (analog inputs, temperature, and fan speeds) in the ADM1024 is started by writing to Configuration Register 1 and setting Start (Bit 0) high. The INT_Enable (Bit 1) should be set to 1, and INT Clear (Bit 3) set to 0 to enable
-22-
REV. B
ADM1024
interrupts. The THERM enable bit (Bit 2) should be set to 1 and the THERM Clear bit (Bit 6) should be set to 0 to enable temperature interrupts at the THERM pin. Apart from initially starting together, the analog measurements and fan speed measurements proceed independently, and are not synchronized in any way. The time taken to complete the analog measurements depends on how they are configured, as described elsewhere. The time taken to complete the fan speed measurements depends on the fan speed and the number of tachometer output pulses per revolution. Once the measurements have been completed, the results can be read from the Value Registers at any time.
Reduced Power and Shutdown Mode
nal ADC. Full shutdown mode may then be achieved by setting Bit 0 of the Test Register to 1. This turns off the analog output and stops the monitoring cycle, if running, but does not affect the condition of any of the registers. The device will return to its previous state when this bit is reset to 0.
Application Circuit
The ADM1024 can be placed in a low power mode by setting Bit 0 of the Configuration Register to 0. This disables the inter-
Figure 18 shows a generic application circuit using the ADM1024. The analog monitoring inputs are connected to the power supplies including two processor core voltage inputs. The VID inputs are connected to the processor voltage ID pins. There are two tachometer inputs from fans, and the analog output is used to control the speed of a third fan. An opto-sensor for chassis intrusion detection is connected to the CI input. Of course, in an actual application, every input and output may not be used, in which case unused analog and digital inputs should be tied to analog or digital ground as appropriate.
12V 5V
THERM I/O TO OTHER CIRCUITS
5V NTEST OUT/ADD THERM VID0/IRQ0 VID1/IRQ1 VID2/IRQ2 VID3/IRQ3 VID4/IRQ4 FROM VID PINS OF PROCESSOR
SDA 1N914 1N914 5V CMOS BACKUP BATTERY MRD901 SERIAL BUS SCL FAN1/AIN1
74HC132
100k N1 N3 10 F 5V INT TO PROCESSOR 12V + 2N2219A 39k 10k NTEST IN/AOUT VCC 10k RESET D1- D1+ FAN2/AIN2 CI GND D 10k N2 N4 + 0.1 F VCC INT
ADM1024
510
+VCCP1 +2.5VIN/D2+ +VCCP2/D2-
510 510
470k
510
+5VIN +12VIN
510
OP295
TEMP. SENSING TRANSISTOR
Figure 18. Application Circuit
REV. B
-23-
ADM1024
ADM REGISTERS Table VI. Address Pointer Register
Bit 7-0
Name Address Pointer
R/W Write
Description Address of ADM1024 Registers. See the tables below for detail.
Table VII. List of Registers
Hex Address 13h
Description Internal Temperature Hardware Trip Point
Power-On Value (Binary Bit 7-0) = 70C
Notes Can be written only if the write once bit in Configuration Register 2 has not been set. Values higher than 70C will have no affect as the fixed trip point in register 16h will be reached first. Can be written only if the write once bit in Configuration Register 2 has not been set. Values higher than 85C will have no affect as the fixed trip point in register 17h will be reached first. Setting Bit 0 of this register to 1 selects shutdown mode. Caution: Do not write to any other bits in this register. This register configures the input channels and configures VID0 to VID4 as processor voltage ID or interrupt inputs. Read Only. Cannot be changed. Read Only. Cannot be changed.
14h
External Temperature Hardware Trip Point
= 85C
15h 16h 17h 18h 19h 1Ah 1Bh 20h 21h 22h 23h 24h 25h 26h 27h 28h 29h 2Ah 2Bh
Test Register Channel Mode Register Internal Temperature Fixed Hardware Trip Point External Temperature Fixed Hardware Trip Point Programmed Value of Analog Output AIN1 Low Limit AIN2 Low Limit 2.5 V Measured Value/Ext. Temp2 VCCP1 Measured Value VCC Measured Value 5 V Value 12 V Measured Value VCCP2 Measured Value Ext. Temp1 Value Internal Temperature Value FAN1/AIN1 Value FAN2/AIN1 Value Reserved 2.5 V/Ext. Temp2 High Limit
0000 00X0 0000 0000 = 70C = 85C 1111 1111 Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate
Read Only Read Only Read Only Read Only Read Only Read Only Read Only. Stores the measurement from a diode sensor connected to Pins 13 and 14. Read Only. This register is used to store eight bits of the internal temperature reading. Read Only. Stores FAN1 or AIN1 reading, depending on the configuration of Pin 5. Read Only. Stores FAN2 or AIN2 reading, depending on the configuration of Pin 6. Stores high limit for 2.5 V input or, in temperature mode, this register stores the high limit for a diode sensor connected to Pins 17 and 18. Stores low limit for 2.5 V input or, in temperature mode, this register stores the low limit for a diode sensor connected to Pins 17 and 18.
2Ch
2.5 V/Ext. Temp2 Low Limit
Indeterminate
2Dh 2Eh 2Fh 30h 31h 32h 33h 34h
VCCP1 High Limit VCCP1 Low Limit VCC High Limit VCC Low Limit 5 V High Limit 5 V Low Limit 12 V High Limit 12 V Low Limit
Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate
-24-
REV. B
ADM1024
Table VII (continued)
Hex Address 35h 36h 37h 38h 39h 3Ah 3Bh 3Ch 3Dh 3Eh 3Fh 40h 41h 42h 43h 44h 46h 47h 49h 4Ah 4Ch 4Dh
Description VCCP2 High Limit VCCP2 Low Limit Ext. Temp1 High Limit Ext. Temp1 Low Limit Internal Temp. High Limit Internal Temp. Low Limit AIN1/FAN1 High Limit AIN2/FAN2 High Limit Reserved Company ID Number Revision Number Configuration Register 1 Interrupt INT Status Register 1 Interrupt INT Status Register 2 INT Mask Register 1 INT Mask Register 2 Chassis Intrusion Clear Register VID0-3/Fan Divisor Register VID4 Register Configuration Register 2 Interrupt Status Register Mirror No. 1 Interrupt Status Register Mirror No. 2
Power-On Value (Binary Bit 7-0) Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate Indeterminate 0100 0001
Notes
Stores high limit for a diode sensor connected to Pins 13 and 14. Stores low limit for a diode sensor connected to Pins 13 and 14. Stores the high limit for the internal temperature reading. Stores the low limit for the internal temperature reading. Stores high limit for AIN1 or FAN1, depending on the configuration of Pin 5. Stores high limit for AIN2 or FAN2, depending on the configuration of Pin 6.
This location will contain the company identification number (Read Only). 0001 nnnn Last four bits of this location will contain the revision number of the part (Read Only). 0000 1000 See Table IX 0000 0000 See Table X 0000 0000 See Table XI 0000 0000 See Table XII 0000 0000 See Table XIII 0000 0000 See Table XIV 0101 (VID3-VID0) See Table XV 1000 000 (VID4) See Table XVI 0000 0000 See Table XVII 0000 0000 See Table XVIII 0000 0000 See Table XIX
Table VIII. Register 16h, Channel Mode Register (Power-On Default = 00h)
Bit Name 0 1 2 FAN1/AIN1 FAN2/AIN2 2.5 V, VCCP2/D2 Int. VCC IRQ0 EN IRQ1 EN IRQ2 EN VID/IRQ
R/W R/W R/W R/W
Description Clearing this bit to 0 configures Pin 5 as FAN1 input. Setting this bit to 1 configures Pin 5 as AIN1. Power-on default = 0. Clearing this bit to 0 configures Pin 6 as FAN2 input. Setting this bit to 1 configures Pin 6 as AIN2. Power-on default = 0. Clearing this bit to 0 configures Pins 17 and 18 to measure VCCP2 and 2.5 V. Setting this bit to 1 configures Pins 17 and 18 as an input for a second remote temperature-sensing diode. Power-on default = 0. Clearing this bit to 0 sets the measurement range for the internal VCC measurement to 3.3 V. Setting this bit to 1 sets the internal VCC measurement range to 5 V. Power-on default = 0. Setting this bit to 1 enables Pin 24 as an active high interrupt input, provided Pins 20 to 24 have been configured as interrupts by setting Bit 7 of the Channel Mode Register. Power-on default = 0. Setting this bit to 1 enables Pin 23 as an active high interrupt input, provided Pins 20 to 24 have been configured as interrupts by setting Bit 7 of the Channel Mode Register. Power-on default = 0. Setting this bit to 1 enables Pin 22 as an active high interrupt input, provided Pins 20 to 24 have been configured as interrupts by setting Bit 7 of the Channel Mode Register. Power-on default = 0. Clearing this bit to 0 configures Pins 20 to 24 as processor voltage ID inputs. Setting this bit to 1 configures Pins 20 to 24 as interrupt inputs. Power-on default = 0.
3 4 5 6 7
R/W R/W R/W R/W R/W
REV. B
-25-
ADM1024
Table IX. Register 40h, Configuration Register 1 (Power-On Default = 08h)
Bit 0
Name START
R/W R/W
Description Logic 1 enables startup of ADM1024; Logic 0 places it in standby mode. Caution: The outputs of the interrupt pins will not be cleared if the user writes a 0 to this location after an interrupt has occurred (see "INT Clear" bit). At startup, limit checking functions and scanning begins. Note, all high and low limits should be set into the ADM1024 prior to turning on this bit (Power-On Default = 0). Logic 1 enables the INT_output. 1 = Enabled 0 = Disabled (Power-On Default = 0). 0 = THERM disabled 1 = THERM enabled During Interrupt Service Routine (ISR), this bit is asserted Logic 1 to clear INT output without affecting the contents of the Interrupt Status Register. The device will stop monitoring. It will resume upon clearing of this bit. (Power-On Default = 0) Setting this bit generates a low going 45 ms reset pulse at Pin 12. This bit is self-clearing and power-on default is 0. Default = 0 A 1 clears the THERM output without changing the Status Register contents. Logic 1 restores power-on default values to the Configuration Register, Interrupt Status Registers, Interrupt Mask Registers, Fan Divisor Register, and the Temperature Configuration Register. This bit automatically clears itself since the power-on default is 0.
1 2 3
INT_Enable THERM Enable INT_Clear RESET Reserved THERM CLR Initialization
R/W R/W R/W
4 5 6 7
R/W R/W R/W R/W
Table X. Register 41h, Interrupt Status Register 1 (Power-On Default = 00h)
Bit 0 1 2 3 4 5 6 7
Name 2.5 V/External Temp2 Error VCCP1 Error VCC Error 5 V Error Internal Temp Error External Temp1 Error FAN1/AIN1 Error FAN2/AIN2 Error
R/W Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only
Description A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a temperature interrupt has been set, or that a High or Low limit has been exceeded. A 1 indicates that a temperature interrupt has been set, or that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded.
Table XI. Register 42h, Interrupt Status Register 2 (Power-On Default = 00h)
Bit 0 1 2 3 4 5 6 7
Name 12 V Error VCCP2 Error Reserved Reserved Chassis Error THERM Interrupt D1 Fault D2 Fault
R/W Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only
Description A 1 indicates a High or Low limit has been exceeded. A 1 indicates a High or Low limit has been exceeded. Undefined Undefined A 1 indicates Chassis Intrusion has gone high. Indicates that THERM pin has been pulled low by an external source. Short or Open-Circuit Sensor Diode D1 Short or Open-Circuit Sensor Diode D2
NOTES 1. Any time the Status Register is read out, the conditions (i.e., Register) that are read are automatically reset. In the case of the channel priority indication, if two or more channels were out of limits, then another indication would automatically be generated if it was not handled during the ISR. 2. In the Mask Register, the errant voltage interrupt may be disabled until the operator has time to clear the errant condition or set the limit higher/lower.
-26-
REV. B
ADM1024
Table XII. Register 43h, INT Interrupt Mask Register 1 (Power-On Default = 00h)
Bit 0 1 2 3 4 5 6 7
Name 2.5 V/Ext. Temp2 VCCP1 VCC 5V Int. Temp Ext. Temp1 FAN1/AIN1 FAN2/AIN2
R/W Read/Write Read/Write Read/Write Read/Write Read/Write Read/Write Read/Write Read/Write
Description A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt.
Table XIII. Register 44h, INT Mask Register 2 (Power-On Default = 00h)
Bit 0 1 2 3 4 5 6 7
Name 12 V VCCP2 Reserved Reserved CI THERM (Input) D1 Fault D2 Fault
R/W Read/Write Read/Write Read/Write Read/Write Read/Write Read/Write Read/Write Read/Write
Description A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt. Power-Up Default Set to Low Power-Up Default Set to Low A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt. A 1 disables the corresponding interrupt status bit for INT interrupt.
Table XIV. Register 46h, Chassis Intrusion Clear (Power-On Default = 00h)
Bit 0-6 7
Name Reserved Chassis Int. Clear
R/W Read Only Read/Write
Description Undefined, always reads as 00h A 1 outputs a minimum 20 ms active low pulse on the Chassis Intrusion pin. The register bit clears itself after the pulse has been output.
Table XV. Register 47h, VID0-3/FAN Divisor Register (Power-On Default = 0101(VID3-0))
Bit 0-3 4-5
Name VID FAN1 Divisor
R/W Read Read/Write
Description The VID<3:0> inputs from processor core power supplies to indicate the operating voltage (e.g., 1.3 V to 3.5 V). Sets counter prescaler for FAN1 speed measurement. <5:4> = 00 - divide by 1. <5:4> = 01 - divide by 2. <5:4> = 10 - divide by 4. <5:4> = 11 - divide by 8. Sets counter prescaler for FAN2 speed measurement. <7:6> = 00 - divide by 1. <7:6> = 01 - divide by 2. <7:6> = 10 - divide by 4. <7:6> = 11 - divide by 8.
6-7
FAN2 Divisor
Read/Write
Table XVI. Register 49h, VID4/Device ID Register (Power-On Default = 1000000(VID4))
Bit 0 1-7
Name VID4 Reserved
R/W Read Only Read Only
Description VID4 Input from Pentium Undefined, always reads as 1000 000(VID4)
REV. B
-27-
ADM1024
Table XVII. Register 4Ah, Configuration Register 2 (Power-On Default <7:0> = 00h)
Bit Name Thermal INT Mask 1 Ambient Temp Fan Control Register Write Once Bit 2 Remote Temp Fan Control Register Write Once Bit 3 THERM Interrupt Mode 4, 5 Reserved 6 IRQ3 EN 0
R/W Read/Write Read/Write Once
Description Setting this bit masks the thermal interrupts for the INT output ONLY. The THERM output will still be generated, regardless of the setting of this bit. Writing a 1 to this bit will lock in the values set into the ambient temperature automatic fan control register 13h. This register will not be able to be written again until a reset is performed (either POR, Hard Reset, or Soft Reset). Writing a 1 to this bit will lock in the values set into the remote temperature automatic fan control register 14h. This register will not be able to be written again until a reset is performed (either POR, Hard Reset, or Soft Reset). If this bit is 0, the THERM output operates in default mode. If this bit is 1, the THERM output operates in ACPI mode. Reserved Setting this bit to 1 enables Pin 21 as an active high interrupt input, provided Pins 20 to 24 have been configured as interrupts by setting Bit 7 of the Channel Mode Register. Power-on default = 0. Setting this bit to 1 enables Pin 20 as an active high interrupt input, provided Pins 20 to 24 have been configured as interrupts by setting Bit 7 of the Channel Mode Register. Power-on default = 0.
Read/Write Once
Read/Write Read Only Read/Write
7
IRQ4 EN
Read/Write
Table XVIII. Register 4Ch, Interrupt Status Register 1 Mirror (Power-On Default <7:0> = 00h)
Bit Name 0 1 2 3 4 5 6 7 2.5 V/Ext. Temp2 Error VCCP1 Error VCC Error 5 V Error Internal Temp Error External Temp1 Error FAN1/AIN1 Error FAN2/AIN2 Error
R/W Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only
Description A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a temperature interrupt has been set, or that a High or Low limit has been exceeded. A 1 indicates that a temperature interrupt has been set, or that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded. A 1 indicates that a High or Low limit has been exceeded.
Table XIX. Register 4DH, Interrupt Status Register 2 Mirror (Power-On Default <7:0> = 00h)
Bit Name 0 1 2 3 4 5 6 7 12 V Error VCCP2 Error Reserved Reserved Chassis Error THERM Interrupt D1 Fault D2 Fault
R/W Read Only Read Only Read Only Read Only Read Only Read Only Read Only Read Only
Description A 1 indicates a High or Low limit has been exceeded. A 1 indicates a High or Low limit has been exceeded. Undefined Undefined A 1 indicates Chassis Intrusion has gone high. Indicates that THERM pin has been pulled low by an external source. Short or Open-Circuit Sensor Diode D1 Short or Open-Circuit Sensor Diode D2
An error that causes continuous interrupts to be generated may be masked in its respective mask register, until the error can be alleviated.
-28-
REV. B
ADM1024
OUTLINE DIMENSIONS 24-Lead Thin Shrink Small Outline Package [TSSOP] (RU-24)
Dimensions shown in millimeters
7.90 7.80 7.70
24
13
4.50 4.40 4.30 6.40 BSC
1 12
PIN 1 0.65 BSC 0.15 0.05 0.30 0.19 0.10 COPLANARITY 1.20 MAX
SEATING PLANE
0.20 0.09
8 0
0.75 0.60 0.45
COMPLIANT TO JEDEC STANDARDS MO-153AD
REV. B
-29-
ADM1024 Revision History
Location 3/04--Data Sheet changed from REV. A to REV. B. Page
Changes to ABSOLUTE MAXIMUM RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Changes to ORDERING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Updated OUTLINE DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2/01--Data Sheet changed from REV. 0 to REV. A.
Changes to Power Supply and Analog-to-Digital Converter sections of SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
-30-
REV. B
-31-
-32-
C00059-0-3/04(B)
This datasheet has been download from: www..com Datasheets for electronics components.


▲Up To Search▲   

 
Price & Availability of ADM1024ARUZ-REEL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X