Current Transducer LTS 15-NP For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 15 At Electrical data I PN IP I PDC VOUT NS RL R IM TCR IM VC IC Primary nominal r.m.s. current Primary current, measuring range Overload capability Analog output voltage @ I P IP = 0 Number of secondary turns ( 0.1 %) Load resistance Internal measuring resistance ( 0.5 %) Thermal drift of R IM Supply voltage ( 5 %) Current consumption @ VC = 5 V 15 At 0 .. 48 At 250 At 2.5 (0.625*IP/IPN) V 2.5 1) V 2000 2 k 83.33 < 50 ppm/K 5 V 28+ IS2) + (VOUT/RL)mA Features * Closed loop (compensated) multi* * * * * range current transducer using the Hall effect Unipolar voltage supply Compact design for PCB mounting Insulated plastic case recognized according to UL 94-V0 Incorporated measuring resistance Extended measuring range. Typ Advantages * * * * * * * Excellent accuracy Very good linearity Very low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference * Current overload capability. Accuracy - Dynamic performance data X L Accuracy @ IPN , T A = 25C Accuracy with R IM @ IPN , T A = 25C Linearity error - 10C .. + 85C - 40C .. - 10C Thermal drift of the gain - 40C .. + 85C Residual voltage @ IP = 0,after an overload of 3 x IPN 5 x IPN 10 x IPN Reaction time @ 10 % of IPN Response time @ 90 % of IPN di/dt accurately followed Frequency bandwidth (0 .. - 0.5 dB) (- 0.5 .. 1 dB) 0.2 0.7 < 0.1 Typ 65 % % % Max 120 ppm/K 170 ppm/K 50 3) ppm/K 0.5 mV 2.0 mV 2.0 mV ns ns A/s kHz kHz TCVOUT Thermal drift of VOUT @ IP = 0 TCG VOM Applications * AC variable speed drives and servo * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies * Switched Mode Power Supplies * Power supplies for welding applications. (SMPS) (UPS) motor drives tr a tr di/dt f < 100 < 400 > 35 DC .. 100 DC .. 200 General data TA TS m Ambient operating temperature Ambient storage temperature Mass Standards - 40 .. + 85 C - 40 .. + 100 C 10 g EN 50178 : 1997 IEC 60950-1 : 2001 Application domain * Industrial. Copyright protected. Notes : 1) 2) 3) Absolute value @ T A = 25C, 2.475 < VOUT < 2.525 Please see the operation principle on the other side Only due to TCR IM. 050713/15 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 1/3 LEM Components Tope Co., Ltd. Tel: (02) 8228-0658 Fax: (02) 8228-0659 http://www.sensor.com.tw www.lem.com e-mail: tope@ms1.hinet.net Current Transducer LTS 15-NP Isolation characteristics Vd Vw Ve dCp dCl CTI R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn Impulse withstand voltage 1.2/50 s 3 >8 kV kV kV mm mm Min R.m.s. voltage for partial discharge extinction @ 10pC >1.5 Creepage distance 4) Clearance distance 5) Comparative Tracking Index (Group III a ) Min 15.5 6.35 175 Application examples According to EN 50178 and IEC 61010-1 standards and following conditions : * Over voltage category OV 3 * Pollution degree PD2 * Non-uniform field EN 50178 dCp, dCI, VW Single isolation Reinforced isolation 4) 5) IEC 61010-1 Nominal voltage 600 V 300 V Rated isolation voltage 600 V 300 V Notes : On housing On PCB with soldering pattern UTEC93-703. Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. 050713/15 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/3 LEM Components www.lem.com Dimensions LTS 15-NP (in mm. 1 mm = 0.0394 inch) Operation principle Bottom view Front view Back view Right view Number of primary turns Primary nominal r.m.s. current IPN [ A ] 15 Nominal output voltage VOUT [ V ] 2.5 0.625 Primary resistance R P [ m ] 0.18 Primary insertion inductance L P [ H ] 0.013 IN Recommended connections 6 5 4 OUT 1 1 6 2 5 3 4 OUT 2 7.5 2.5 0.625 0.81 0.05 IN 1 6 2 5 3 4 OUT 3 5 2.5 0.625 1.62 0.12 IN 1 2 3 Mechanical characteristics * General tolerance * Fastening & connection of primary Recommended PCB hole * Fastening & connection of secondary Recommended PCB hole * Additional primary through-hole 0.2 mm 6 pins 0.8 x 0.8 mm 1.3 mm 3 pins 0.5 x 0.35 mm 0.8 mm 3.2 mm Output Voltage - Primary Current VOUT [ V ] 5 4.5 3.125 2.5 1.875 0.5 Remarks * VOUT is positive when IP flows from terminals 1, 2, 3 to terminals 6, 5, 4. * Temperature of the primary jumper should not exceed 100C. - IP - IPN 0 IPN IP IP [ At ] 050713/15 Page 3/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM Components www.lem.com |
Price & Availability of LTS15-NP |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |