Bulletin PD-21047 05/05 IRUD400CW60 FRED TM Features * Ultrafast Recovery * Lead-Free Benefits * * * * Reduced RFI and EMI Higher Frequency Operation Reduced Snubbing Reduced Parts Count LUG TERMINAL ANODE 1 LUG TERMINAL ANODE 2 Ultrafast, Soft Recovery Diode VR = 600V IF(AV) = 400A BASE COMMON CATHODE Description/ Applications These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are significant portion of the total losses. Absolute Maximum Ratings Parameters (*) VR IF(AV) Cathode-to-Anode Voltage Continuous Forward Current @ TC = 25C @ TC = 85C @ TC = 97C IFSM PD Single Pulse Forward Current Maximum Power Dissipation @ TC = 25C @ TC = 97C Max 600 330 230 200 1200 660 280 Units V A W Case Styles IRUD400CW60 TO-244 (*) Per Leg unless otherwise specified 1 IRUD400CW60 Bulletin PD-21047 05/05 Electrical Characteristics (per Leg) @ TJ = 25C (unless otherwise specified) Parameters VBR VFM Breakdown Voltage, Forward Voltage Min Typ Max Units Test Conditions 600 1.45 1.67 1.13 1.39 0.3 5 2.0 2.3 1.4 1.8 1.38 mA nH V IR = 100A IF = 200A IF = 400A IF = 200A @ TJ = 150C IF = 400A @ TJ = 150C TJ = 150C, VR = VR Rated from top of terminal hole to mounting plane IRM LS Reverse Leakage Current Series Inductance - Dynamic Recovery Characteristics @ TJ = 25C (unless otherwise specified) Parameters trr Reverse Recovery Time Min Typ Max Units Test Conditions 90 240 8.3 24 830 4730 nC A ns If = 200A, dif/dt = 200A/s, Vr = 200V If = 200A, dif/dt =200A/s, Vr =200V @ TJ = 150C If = 200A, dif/dt = 200A/s, Vr = 200V If = 200A, dif/dt =200A/s, Vr =200V @ TJ = 150C If = 200A, dif/dt = 200A/s, Vr = 200V If = 200A, dif/dt =200A/s, Vr =200V @ TJ = 150C IRRM Peak Recovery Current - Qrr Reverse Recovery Charge - Thermal - Mechanical Characteristics Parameters TJ TStg RthJC RthCS Wt T Max. Junction Temperature Range Max. Storage Temperature Range Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Thermal Resistance, Case to Heatsink Weight Mounting Torque Mounting Torque Center Hole Terminal Torque Vertical Pull 2 inch. Lever Pull Per Leg Per Module Min - 40 - 40 30 (3.4) 12 (1.4) 30 (3.4) - Typ 0.10 68 (2.4) - Max 150 150 0.19 0.095 40 (4.6) 18 (2.1) 40 (4.6) 80 35 Units C C/W g (oz) lbf.in (N.m) lbf.in 2 IRUD400CW60 Bulletin PD-21047 05/05 1000 Reverse Current - IR (A) 1000 100 10 1 0.1 0.01 0 TJ = 150C 25C Instantaneous Forward Current - IF (A) 100 100 200 300 400 500 Reverse Voltage - VR (V) 600 Fig. 2 - Typical Reverse Current vs. Reverse Voltage (per Leg) Allowable Case Temperature (C) 10 Tj = 150C Tj = 25C 160 IRUD400CW60 RthJC = 0.19 K/W 140 120 (D = 0.50) DC 100 80 60 0 50 100 150 200 Current Rating - IDC (A) 250 1 0 0.5 1 1.5 Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop vs. Instantaneous Forward Current (per Leg) 2 Fig. 3 - Max. Current Rating Capability (per Leg) 3 IRUD400CW60 Bulletin PD-21047 05/05 200 Forward Power Loss (W) 300 RMS Limit If = 200A Vrr = 200V 150 DC 200 Tj = 150C 100 50 D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50 t rr (ns) 100 0 0 50 100 150 200 Forward Current (A) Fig. 4 - Typical Recovery Current vs. dif /dt (per Leg) Tj = 25C 0 100 200 300 400 500 dif/ dt - (A/s) Fig. 5 - Typical Reverse Recovery Time vs. dif /dt (per Leg) 8000 If = 200A Vrr = 200V 40 If = 200A Vrr = 200V 6000 Tj = 150C Q RR (nC) 30 Tj = 150C 4000 I RR (A) 20 2000 Tj = 25C 10 Tj = 25C 0 100 200 300 dif/ dt - (A/s) 400 500 0 100 200 300 dif/ dt - (A/s) 400 500 Fig. 6 - Typical Reverse Recovery Charge vs. dif /dt (per Leg) Fig. 7 - Typical Reverse Recovery Current vs. dif /dt (per Leg) 4 IRUD400CW60 Bulletin PD-21047 05/05 Reverse Recovery Circuit VR = 200V 0.01 L = 70H D.U.T. dif/dt ADJUST di F /dt D G IRFP250 S Fig. 8 - Reverse Recovery Parameter Test Circuit Outline Table Conforms to JEDEC Outline TO-244 Dimensions in millimeters and (inches) 5 IRUD400CW60 Bulletin PD-21047 05/05 Ordering Information Table Device Code IR 1 1 2 3 4 5 6 - UD 2 400 3 C 4 W 5 60 6 International Rectifier UD = Fred Current Rating (400 = 400A) Circuit Configuration (C = Common Cathode) W = TO-244 Wire Bondable not Isolated Voltage Rating (60 = 600V) Data and specifications subject to change without notice. This product has been designed for Industrial Level. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 05/05 6 |
Price & Availability of IRUD400CW60
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |