If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Current Transducers HTC 1000..3000-S For the electronic measurement of currents: AC,DC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN DC= 1000..3000 A VOUT = 10 V Electrical data Primary continuous direct current (nominal) IPN DC (A) 1000 2000 3000 Primary current measuring range IPM (A) 1100 2200 3300 Type Features HTC 1000-S HTC 2000-S HTC 3000-S * Hall effect measuring principle * Galvanic insulation between primary 15 < 20 > 500 10 < 100 2.5 2 V mA M V kV k and secondary circuit VC IC RIS Vout ROUT Vd RL Supply voltage ( 3 %) Current consumption Insulation resistance @ 500 VDC Output voltage (Analog) @ IPN DC, RL=2k, TA=25C Output internal resistance Rms voltage for AC isolation test, 50 Hz,1min Load resistance * Insulated plastic case recognized according to UL 94-V0 Advantages * Easy installation * Compact * High immunity to external interference Accuracy-Dynamic performance data X L VOE VOH TCVOE TCVOUT tr BW Accuracy @ IPN DC, TA = 25C Linearity error (0 .. IPN DC) Eletrical offset voltage @ TA = 25C Hysteresis offset voltage @ IP = 0, after an excursion of 1 x IPN DC Temperature coefficient of VOE Temperature coefficient of VOUT Response time to 90% of IPN DC step @ di/dt = 100A/s Frequency bandwidth (- 3dB) < 1 %of IPN DC < 1 %of IPN DC < 30 mV < 50 mV < 1.0 mV/K 0.1 %/K 10 s DC .. 10 kHz * Low power consumption Application * Traction General data TA TS m Ambient operating temperature Ambient storage temperature Mass Standards1) - 40 .. + 85 - 40 .. + 85 450 EN 50155 C C g 1) Note : Specification according to IEC 61000-4-3 are not guaranteed between 260 and 290 MHz (value higher by 5% than the specification). Page 1/2 070111/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HTC 1000..3000-S (in mm. 1 mm = 0.0394 inch) Front view R40 D4 0 60 49 PNAMS 2-D8 98 120 70 100 Pins Assignment Bottom view 35 P N A M S : : : : : +V -V Output 0V 0V Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/2 070111/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com |
Price & Availability of HTC1000-S07 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |