Part Number Hot Search : 
01OD00 PE45137 F1000 MAX8500 SB105 2SK131 AM3020 2SK0664G
Product Description
Full Text Search
 

To Download KP100 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Silicon Pressure Sensor ICs
KP100
Surface Mount Capacitive Silicon Absolute Pressure Sensor
KP100
Data Sheet Features * * * * * * Digital output Serial Peripheral Interface (SPI) Offset calibrated CMOS compatible surface micromachining Diagnostic modes SMD housing P-DSOF-8-3
Type KP100 Marking
Marking see below
Ordering Code Pressure Range Q62705-K348 60 kPa- 130 kPa
Package P-DSOF-8-3
Each device is marked with a human readable code on the side of Pins 5 to 8. This code contains the supplier logo, a date code, wafer lot number and an offset code. Product Description The KP100 is an absolute pressure sensor with SPI interface for side airbag applications. The basic accuracy including temperature drift is 5%. The KP100 offers some diagnosis features in order to allow a sensor status analysis.
Data Book
1
2003-05
KP100
Pin Configuration (top view)
Figure 1 Pin Definitions and Functions Pad No. 1 2 3 4 5 6 7 8 Symbol CLKS CS DTA_OUT CLK_IN Function Input; clock for serial interface Input; chip select, active low Output of the serial interface Input; external clock = 4/8 MHz 5 V power supply terminal Data ready signal for serial interface Input for serial interface Ground potential
VDD
DTA_RDY DTA_IN
VSS
Data Book
2
2003-05
KP100
Figure 2
Block Diagram of the KP100
Data Book
3
2003-05
KP100
Functional Description The IC consists of a surface micromachined pressure sensor, a sigma-delta A/D-converter, a digital filter and the SPI-interface. In normal operation, the applied pressure has to be in the range between 60 kPa and 130 kPa and delivers output codes between typ. 7680 and typ. 20190 digits. Absolute Maximum Ratings Parameter Clock Oscillator Voltage on pin CLK_IN Current on pin CLK_IN Serial Peripheral Interface (SPI) Input voltage on pins CLKS, CS and DTA_IN Current on pins CLKS, CS, DTA_IN Temperature Storage temperature Junction temperature Pressure Pressure overload Symbol min. Limit Values typ. - - - max. Unit
VCLK_IN ICKL_IN VCLKS VCS VDTA_IN ICLKS ICS IDTA_IN TS Tj pOL
- 0.3 - 100 - 0.3
VDD +0.3 V
100 A
VDD +0.3 V
- 1.0
-
1.0
mA
- 40 - 40 -
- - -
90 100 200
C C kPa
Note: Stresses above those listed here may cause permanent damage to the device. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ESD Protection Human Body Model (HBM) tests according to: Standard EIA/JESD22-A114-B HBM (covers MIL STD 883D) Parameter ESD-Protection Symbol Limit Values min. max. 2 kV - Unit Notes
VESD
R = 1.5 k, C = 100 pF
2003-05
Data Book
4
KP100
Operating Range Parameter Supply voltage Supply current External clock frequency CLK_IN Operating temperature range Pressure range Electrical Characteristics Parameter Digital output range Resolution Symbol min. Limit Values typ. - 2 - max. 65534 - 20190 digits digits digits 0 - 7680 Unit Symbol min. Limit Values typ. 5.0 1.8 4/8 - - max. 5.5 2.5 + 90 130 V mA C kPa 4.5 1.0 - - 40 60 Unit
VDD IDD fCLK_IN TA RP
4.2/8.4 MHz
RY
-
Output range for a typ. sensitivity (value Y see below) over specified pressure range (for zero offset, at 25 C) Offset a The offset is written on the package in an LC encoded Form, called LC (calculation see below) Sensitivity (see below: transfer function) b Exponent of transfer function (see below) c Repeatability Noise Information rate Filter cutoff frequency (- 3 dB) Accuracy over temperature range (-40 C to 90 C)
- 3000 - 00
6984 TT
digits
- - - - - - -
46 1.25 16 - 7.8 360 5%
- - - 14.5 - - -
digits/ (kPa)1.25 1 digits digits kHz Hz 1
fL f- 3 DB
Data Book
5
2003-05
KP100
*Calculation of the offset a from the LC-code written on the package The offset of each pressure sensor is individually measured at the Infineon production line. It is written on the sensor package in encoded Form. The so called LC code consists of two signs X and Y. The offset a is calculated from the code using the table and the formula below: a = (X x 25 + Y) x 16 - 3000
0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 A V C D E F G H K L M P R S T
Electrical Characteristics Parameter Input pin CLK_IN Input capacitance Input current Input high voltage Input low voltage Input hysteresis "H" output voltage on pins DTA_OUT, DTA_RDY IOH = - 1 mA "L" output voltage on pins DTA_OUT, DTA_RDY IOL = + 1 mA "H" input current on pin CLKS "L" input current on pin CLKS "H" input current on pin DTA_IN "L" input current on pin DTA_IN "H" input current on pin CS "L" input current on pin CS Symbol min. Limit Values typ. - - - - - max. 5 5 - 1.5 - - pF A V V mV V Unit
CCKL_IN ICKL_IN VHCKL_IN VLCKL_IN VINHYST VOH
- -5 3.5 - 150
0.8 VDD -
VLH
-
-
0.1 VDD V
IIH IIL IIH IIL IIH IIL
- - 200 - - 50 - - 200
- - - - - -
50 - 200 - 50 -
A A A A A A
Data Book
6
2003-05
KP100
Electrical Characteristics (cont'd) Parameter Input voltage HIGH level CLKS, CS, DTA_IN Input voltage LOW level CLKS, CS, DTA_IN Input hysteresis on pins CLKS, CS, DTA_IN SPI Timing Tolerances Parameter CS lead time CS lag time CLKS "H" pulse width CLKS "L" pulse width DTA_IN setup time at pin DTA_IN DTA_IN hold time at pin DTA_IN DTA_OUT output delay time at pin DTA_OUT Clock frequency CLKS Clock cycle time DTA_OUT TRI-STATE(R) delay time DTA-RDY Timing DTA_RDY cycle time DTA_RDY pulse width DTA_OUT status valid setup time DTA_OUT status valid delay time DTA_RDY fall time DTA_RDY rise time Symbol min. Limit Values typ. - - - - - - - - - - 128 16 - - - - max. - - - - - - 200 500 - 200 - - 1 1 100 200 ns ns ns ns ns ns ns kHz s ns s s s s ns ns 250 250 880 880 200 200 - - 2 - - - - - - - Unit Symbol min. Limit Values typ. - - 0.5 max. - 1.0 - V V V 4.0 - Unit
VIH VIL
VOH - VLH -
tlead tlag tWH tWL tSU tH tD fCLKS tC tZ tCDR tWDR tSUDO tDO tFDR tRDR
Data Book
7
2003-05
KP100
Transfer Function The general relation between output code and pressure is given by the formula p Y(p) = a + b ---------kPa
c
[ digit ]
Interface description The KP100 digital interface consists of the pins DTA_IN, CLKS, DTA_OUT, CS and DTA_RDY. The interface is active when CS is low. At the DTA_RDY pin a pulse of approx. 16 s appears with a frequency of 7.8 kHz. The rising edge of this pulse indicates that the output register has been loaded with a new 16 bit wide data word, where the first bit is a parity bit. The data can then be clocked out by applying a clock signal at CLKS. With every falling edge of CLKS the DTA_OUT is updated, starting with the parity, followed by the LSB. After the 16th falling edge the MSB appears at DTA_OUT and the readout cycle is completed. Simultaneously data can be loaded into the KP100 via DTA_IN. The data is clocked in with every rising edge at CLKS. Only the three last bits of the input data are relevant. They are used to select the diagnosis modes and to switch between 4 and 8 MHz operation. After completing a read-write cycle the three input bits can be activated by applying a positive pulse at CS of at least 50 s. If for example the diagnosis mode 1 has been choosen the corresponding diagnosis value will appear at DTA_OUT in the next read-write cycle. For the simplest mode of operation the CS and DTA_IN pins are pulled to ground potential. Then only the pins CLKS, DTA_OUT and DTA_RDY are needed to read the pressure data, since the power-on condition of the KP100 is to deliver pressure data in 8 MHz mode. Read Write Cycle A complete read write cycle is shown in the diagram below. DTA_RDY and DTA_OUT are KP100 output signals, CLKS, DTA_IN and CS are KP100 input signals. The first 13 DTA_IN bits are don't care bits.
Data Book
8
2003-05
KP100
Figure 3 Diagnosis Features For transmission reliability the first bit of the data word is a parity bit whereas the next 15 bits are data bits starting with the LSB. Parity is odd in normal mode and even in any diagnosis mode. It is calculated only for the 12 MSBs, the first 3 LSBs are ignored. Besides of the parity bit in the output code there are several additional diagnosis features. In detail these are an automatic fuse-check and three diagnosis modes. Automatic fuse-check: Fuses are used for correcting the transfer function between pressure and output code. An additional parity-fuse guarantees that fuse-data is reliable. If a wrong parity is detected the output code will go to FFFFH, which is defined as an error code. The condition is latched, i.e. the error code will be transmitted until the next power on reset. Diagnosis mode 1: This mode puts the sigma-delta converter into an idle condition where it operates without input signal. This is a good method to check the basic analog performance of the chip. An output code of 8020H ( 3E8H) is expected. Diagnosis mode 2:
Data Book
9
2003-05
KP100
The sensor array is subdivided into two independent areas. In diagnosis 2 mode the difference signal of the two areas is measured. A drift of the diagnosis 2 value indicates a mechanical damage of one or more cells. For an efficient use of this mode it is recommended to store the initial diagnosis 2 value on the application board (e.g. in the C flash) already at the production line. Diagnosis mode 3: This mode applies a general reset to the chip and initiates a special self-test sequence, where the complete digital filter part is checked. After programming the diagnosis 3 mode and activating it by a high-pulse at CS, the following 10 read write cycles must deliver the output values listed below: Number Output value (hex) 1 2 3 4 5 6 7 8 9 10
0000 0000 0000 0000 0900 25E6 4E8D 741B 9135 A664
Note that between these 10 read-write cycles no further CS pulse must be applyed, in order not to end or to restart the diagnosis 3 mode. Also note that no DTA_RDY must be skipped in this mode, since each value will be overwritten by the subsequent value. Any error in these codes indicates an error in the digital circuitry of the chip. Additionally, this diagnosis mode also resets the fuse-check latch. However, a remaining error conditiotion in the fuses will immediately reestablish this latch, so that the output is set to FFFFH.
Data Book
10
2003-05
KP100
Figure 4
Serial Peripheral Interface: Timing Diagram
Figure 5
DTA_RDY Timing Diagram
Data Book
11
2003-05
KP100
Figure 6
Transfer Function
Data Book
12
2003-05
KP100
Package Outlines P-DSOF-8-3 (Plastic Dual Small Outline Flat Package)
You can find all of our packages, sorts of packing and others in our Infineon Internet Page "Products": http://www.infineon.com/products. Data Book 13
Dimensions in mm 2003-05
GMX05998


▲Up To Search▲   

 
Price & Availability of KP100

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X