SB801G THRU SB807G Single Phase 8.0 AMPS. Glass Passivated Bridge Rectifiers Voltage Range 50 to 1000 Volts Current 8.0 Amperes Features UL Recognized File # E-96005 Glass passivated junction Surge overload rating 175 amperes peak Low forward voltage drop High temperature soldering guaranteed: 260 / 10 seconds / 0.375" ( 9.5mm ) lead length at 5 lbs., ( 2.3 kg ) tension Small size, simple installation Leads solderable per MIL-STD-202 Method 208 SB-10 Dimensions in inches and (millimeters) Maximum Ratings and Electrical Characteristics Rating at 25ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20% Symbol SB SB Type Number 801G 802G Maximum Recurrent Peak Reverse Voltage VRRM 50 100 Maximum RMS Voltage VRMS 35 70 Maximum DC Blocking Voltage VDC 50 100 Maximum Average Forward Rectified Current @TA = 50 Peak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC method ) Maximum Instantaneous Forward Voltage @ 4.0A Maximum DC Reverse Current @ TA=25 at Rated DC Blocking Voltage @ TA=125 Typical Thermal Resistance (Note) Operating Temperature Range Storage Temperature Range SB SB SB SB SB Units 803G 804G 805G 806G 807G 200 140 200 400 280 400 8.0 175 1.1 600 420 600 800 1000 560 700 800 1000 V V V A A V uA uA /W I(AV) IFSM VF IR RJC TJ TSTG Note: Thermal Resistance from Junction to Case per Leg. 5 500 6 -55 to +150 -55 to +150 - 750 - RATINGS AND CHARACTERISTIC CURVES (SB801G THRU SB807G) FIG.1- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER BRIDGE ELEMENT 10 FIG.2- MAXIMUM FORWARD CURRENT DERATING CURVE 250 PEAK FORWARD SURGE CURRENT. (A) 200 AVERAGE FORWARD OUTPUT CURRENT AMPERES 8 150 6 100 4 50 2 0 0 1 2 4 6 8 10 20 40 60 80 100 NUMBER OF CYCLES AT 60Hz 0 50 o 100 150 AMBIENT TEMPERATURE. ( C) FIG.3- TYPICAL FORWARD CHARACTERISTICS PER BRIDGE ELEMENT 100 FIG.4- TYPICAL REVERSE CHARACTERISTICS PER BRIDGE ELEMENT 100 INSTANTANEOUS REVERSE CURRENT, MOCROAMPERES INSTANTANEOUS FORWARD CURRENT, AMPERES 10 TJ=125 0C 10 1 Tj=25 C PULSE WIDTH-300 S 1% DUTY CYCLE 0.1 0 1 TJ=25 0C 0.01 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 0.1 0 20 40 60 80 100 120 140 FORWARD VOLTAGE. VOLTS PERCENT OF RATED PEAK REVERSE VOLTAGE. (%) - 751 - |
Price & Availability of SB804G
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |