Part Number Hot Search : 
26715QUQ PYB20 KMM536 74LCX16 LC5223D 6049018 L1005 MA550
Product Description
Full Text Search
 

To Download NLS110-9602J Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 NLS110-9602J
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies 7.0 x 4.25 x 1U package Overvoltage and short circuit protection 110 W with 20 CFM 90 Vac to 264 Vac universal input range EN55022 conducted emissions level B, radiated emissions level A * UL, VDE and CSA safety approvals * CE mark * Available RoHS compliant
The NLS110-9602J is a 110 W universal input ac-dc power supply on a 7 x 4.25 inch card. The NLS110-9602J has proven itself to be highly reliable and versatile product for a wide range of communication and industrial applications, with a very high peak current capability on each output for drive and motor applications. The NLS110-9602J provides 80 W of output power with free air convection cooling which can be boosted to 110 W with 20 CFM of air. Standard features include overvoltage and short circuit protection. The NLS110-9602J with full international safety approval and the CE mark, meets conducted emissions EN55022 level B. The NLS110-9602J is designed for use in low power data networking, computer, telecom and industrial applications such as servers, thermal printers, storage devices, vending machines and POS equipment.
2 YEAR WARRANTY All specifications are typical at nominal input, full load at 25 C unless otherwise stated
1
* * * * *
SPECIFICATIONS
OUTPUT SPECIFICATIONS Total regulation Rise Time Transient response Temperature coefficient Overvoltage protection Short circuit protection +5.1 V Cyclic operation Line and load At turn-on (See table) 1.0 s, max. (See table) 0.02%/C 125%, 10% Yes with auto recovery
GENERAL SPECIFICATIONS Hold-up time Efficiency Isolation voltage Approvals and standards Weight MTBF (@ 25 C) MIL-HDBK-217F
(6,8)
120 Vac @ 60 Hz 120 Vac @ 110 W Input/output Input/chassis
35 ms @ 80 W 25 ms @ 110 W 70% min. 3000 Vac 1500 Vac
EN60950, VDE0805, IEC950 UL1950, CSA C22.2 No. 950 383 g (13.5 oz.) 220,000 hours min.
INPUT SPECIFICATIONS Input voltage range Input frequency range Input surge current (cold start) Safety ground leakage current Input current 120 Vac 230 Vac 120 Vac, 60 Hz 230 Vac, 50 Hz 120 120 230 230 Vac Vac Vac Vac @ @ @ @ 80 W 110 W 80 W 110 W Universal input 90-264 Vac 47-440 Hz 18 A max. 35 A max. 0.45 mA 0.75 mA 0.95 1.35 0.53 0.75 A A A A rms rms rms rms
ENVIRONMENTAL SPECIFICATIONS Thermal performance
Operating ambient, 0 C to +50 C (see derating curve) Non-operating -40 C to +85 C +50 C to +70 C, Derate to amb. convection cooled 50% load 0 C to +50 C, 80 W amb. convection cooled 0 C to +50 C ambient, 110 W 150 LFM forced air Peak (0 C to +50 C, 60 s) (See Note 4) Non-condensing Operating Non-operating 5-500 Hz per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV
Input fuse
UL/IEC127
(11)
F3.15A H, 250 Vac
Relative humidity Altitude
EMC CHARACTERISTICS Conducted emissions Radiated emissions Harmonic current emission correction ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity
EN55022, FCC part 15 EN55022, FCC part 15 EN61000-3-2 EN61000-4-2 EN61000-4-2 EN61000-4-5 EN61000-4-4 EN61000-4-3 EN61000-4-6
Level B Level A Compliant Level Level Level Level Level Level 3 3 3 3 3 3
Vibration (See Note 7) Shock
File Name: nls110.pdf Rev (02): 08 Nov 2005
NLS110-9602J
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
2
OUTPUT VOLTAGE +5.1 V +24 V +12 V -12 V Notes
1 2 3 4 5
OUTPUT CURRENTS MAX 8A 3.5 A 4.5 A 0.5 A
(1)
PEAK 20 A
(2)
FAN
(3)
RIPPLE
(4)
TOTAL REGULATION 2.0% 5.0% 3.0% 3.0%
(5)
MODEL NUMBERS (12,13,14) NLS110-9602J
10 A 4.5 A 5A 1A
50 mV 240 mV 120 mV 120 mV
4.5 A 9A 1.5 A
TRANSIENT RESPONSE NLS110-9602J +5.1 V (7.5 A to 1 0A) +24 V (1.5 A to 3 A) +12 V (2.5 A to 5 A) -12 V (0.5 A to 1 A) 150 mV peak, 1 ms recovery 300 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery
6 7 8 9 10 11
12 13
14
Convection cooled, 80 W maximum. Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total peak power must not exceed 110 W. Forced air, 20 CFM at 1 atmosphere, 110 W maximum. Amplitude is peak-to-peak. Output ripple is measured across a 20 MHz bandwidth using a 12 inch twisted pair terminated with a 10 F capacitor. Total regulation is defined as the static output regulation at 25 C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. Derating curve is application specific for ambient temperatures >50 C. Three orthogonal axes, random vibration, 10 minute test for each axis. For optimum reliability no part of the heatsink should exceed 100 C and no semiconductor case temperature should exceed 115 C. Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. The EMI specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. No external filtering is required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. A line choke, (ac input cords looped twice through an EMI suppression toroid) was used during radiated emissions testing. Considerable radiated testing in 1U six-sided boxes has shown that units can meet level B in typical systems. Application support is available from the factory to assist with EMI compliance. Requires a minimum mounting stand-off of 6.35 mm (0.25 inches) in the end use product. The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative.
DERATING CURVE
Output Power (Watts)
110W 80W
150 LFM FORCED AIR COOLING
NATURAL CONVECTION COOLING
55W 40W
0C 10C 20C 30C 40C 50C 60C 70C
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM
AC INPUT
OUTPUT PIN CONNECTIONS J2 FUNCTION Pin 1 +5.1 V Pin 2 +5.1 V Pin 3 Return Pin 4 Return Pin 5 Return Pin 6 Return Pin 7 +12 V Pin 8 +12 V Pin 9 +24 V Pin 10 PFD Pin 11 -12 V Return Pin 12 -12 V
PIN Pin 1 Pin 2 Pin 3 Pin 1
INPUT CONNECTIONS J1 AC Neutral No Connection AC Line J4 Safety Earth
5V OUTPUT
4.75V HIGH
4.75V
LOW PFD SIGNAL 0-0.4 MAX T1 T2
3.5V MIN T3
Power fail detect signal
50 msT1200 ms T2 will vary with line and load T33 ms Pout: 110 W PFD output is an open collector which will sink 40 mA in the low state.
File Name: nls110.pdf Rev (02): 08 Nov 2005
NLS110-9602J
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Mechanical Notes
A All dimensions are in inches (mm).
3
2
7.00 (177.80) 6.500 (165.100)
4
3
J4
1
T1 (REF) 12 4.25 (107.95) 3.750 (95.250)
T2 (REF) J2
Recommended direction for forced air relative to power supply orientation shown below.
1 2 3 4 Optimum. Very good. Not recommended. Not recommended.
F1 1 3 J1 1
0.25 (6.35) 0.25 (6.35)
J5
2 1
TOLERANCE: .XXX: 0.005 (0.127) .XX: 0.02 (0.51)
ALL DIMENSIONS IN INCHES (mm)
Input and output connectors
AC (J1) connector type Molex 26-60-4030 or equivalent.
Mating connectors
AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J2) mating connector type Molex Spox type 26-03-3121 and contact 08-52-0113. Earth (J4) mating connector type Molex 90028.
DC (J2) connector type 12 position Molex Spox type 26-48-1125 or equivalent. Earth (J4) connector type Male 0.250 quick disconnect.
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-0186 Licence No.130253 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C
Datasheet (c) Artesyn Technologies(R) 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: Application Note
www.artesyn.com
File Name: nls110.pdf Rev (02): 08 Nov 2005


▲Up To Search▲   

 
Price & Availability of NLS110-9602J

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X