![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
( DataSheet : www..com ) Low Signal Relay Suitable for handling low signals in computer peripherals, telecommunications and security equipment s Capable of switching loads up to 2 A s Conforms to FCC part 68 1500 V surge withstand s Reliable bifurcated crossbar contacts s s G5V-2 Fully-sealed construction Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-2-DC12). Type Standard High-sensitivity Ultra-sensitive Contact form DPDT Construction Fully-sealed Part number G5V-2 G5V-2-H G5V-2-H1 Specifications s CONTACT DATA Load Rated load Contact material Carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load Resistive load (p.f. = 1) 0.50 A at 125 VAC 2 A at 30 VDC Ag (Au clad) 2A 125 VAC 125 VDC 2A 62.50 VA 60W 10 A, 10 mVDC www..com www..com G5V-2 s COIL DATA Standard type Rated voltage (VDC) 3 5 6 9 12 24 48 Rated current (mA) 166.70 100 83.30 55.60 41.70 20.80 12 Coil resistance () 18 50 72 162 288 1,152 4,000 Coil inductance (Ref. value) (H) Armature OFF 0.04 0.09 0.16 0.31 0.47 1.98 -- Armature ON 0.05 0.11 0.19 0.49 0.74 2.68 -- Pick-up voltage 75% max. Dropout voltage 5% min. Maximum voltage G5V-2 % of rated voltage Power consumption (mW) 120% max. Approx. 500 at 65C (149F) 110% max. Approx. 580 at 60C (140F) High-sensitivity type Rated voltage (VDC) 3 5 6 9 12 24 48 Rated current (mA) 120 72 60 40 30 15 7.5 Coil resistance () 25 70 100 225 400 1,600 6,400 Coil inductance (Ref. value) (H) Armature OFF 0.04 0.12 0.18 0.40 0.75 3.16 -- Armature ON 0.07 0.19 0.29 0.62 1.18 4.81 -- Pick-up voltage Dropout voltage Maximum voltage Power consumption (mW) % of rated voltage 75% max. 5% min. 120% max. Approx. 360 at 70C (158F) 110% max. at 70C (158F) Ultra-sensitive type Rated voltage (VDC) 3 5 6 9 12 24 48 Rated current (mA) 50 30 25 16.70 12.50 8.30 6.25 Coil resistance () 60 166.70 240 540 960 2,880 7,680 Coil inductance (Ref. value) (H) Armature OFF 0.18 0.46 0.70 1.67 2.90 6.72 20.10 Armature ON 0.26 0.71 0.97 2.33 3.99 9.27 26.70 Pick-up voltage Dropout voltage Maximum voltage Power consumption (mW) % of rated voltage 75% max. 5% min. 150% max. Approx. 150 at 70C (158F) Approx. 200 Approx. 300 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C (73F). 2 G5V-2 s CHARACTERISTICS Contact resistance Operate time Release time Bounce time Operating frequency Insulation resistance Dielectric strength 50 m max. G5V-2, G5V-2-H, 100 m max. G5V-2-H1 7 ms max. (mean value: approx. 3.5 ms) 3 ms max. (mean value: approx. 0.8 ms) Mean value: approx. 0.5 ms Mean value: approx. 3.5 ms 36,000 operations/hour 1,800 operations/hour (under rated load) 1,000 M min (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles 750 VAC, 50/60 Hz for 1 minute between contacts of same poles (500 VAC, 50/60 Hz for 1 minute between contacts of same poles for ultra-sensitive type) 1,500 V 10 X 160 s (conforms to part 68 of FCC rules) 10 to 55 Hz, 1.50 mm (0.59 in) double amplitude G5V-2 Operate Release Mechanical Electrical Surge withstand voltage Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Ambient temperature Operating/storage Humidity Service life Mechanical Electrical Weight Note: Data shown are of initial value. 1,000 m/s2 (approx. 100 G) 200 m/s2 (approx. 20 G) -25 to 70C (-13 to 158F) 35% to 85% RH 15 million operations min. (at operating frequency of 36,000 operations/hour) See "Characteristic Data" 6 g (0.21 oz) s CHARACTERISTIC DATA Maximum switching capacity Electrical service life Ambient temperature vs. maximum voltage Service life (x103 operations) Rated operating current (A) Rated operating voltage (V) Rated operating current (A) Maximum voltage (%) Ambient temperature [C (F)] ---- 48 VDC coil voltage (standard type) All other types and voltages 3 G5V-2 G5V-2 Dimensions Unit: mm (inch) s RELAYS Fully-sealed Terminal arrangement/Internal (bottom view) Mounting holes (bottom view) Note: 1. and indicate mounting orientation marks. 2. A tolerance of 0.10 (0.004) applies to the above dimensions. s APPROVALS UL (File No. E41515)/CSA (File No. LR24825) Type G5V-2 G5V-2-H G5V-2-H1 Contact form DPDT Coil rating 3 to 48 VDC 3 to 24 VDC 3 to 48 VDC Contact ratings 0.6 A, 125 VAC 0.6 A,110 VDC 2.0 A, 30 VDC 0.6 A, 125 VAC 0.6 A, 110 VDC 1.0 A, 24 VDC Note: 1. The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. 3. Complies with UL1950 Basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings). NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC RLY7 01/00 Specifications subject to change without notice. 4 654321 654321 654321 OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in the U.S.A. |
Price & Availability of G5V-2-H
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |