If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
19-3556; Rev 1; 3/05 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers General Description The MAX7347/MAX7348/MAX7349 interfaced peripherals provide microprocessors with management of up to 64 key switches. Key inputs are monitored statically, not dynamically scanned, to ensure low-EMI operation. The MAX7347 can monitor up to 24 switches, the MAX7348 can monitor up to 40 switches, and the MAX7349 can monitor up to 64 switches. The switches can be metallic or resistive (carbon) up to 5k. The key controller debounces and maintains a FIFO of key-press events (including autorepeat, if enabled). An interrupt (INT) output can be configured to alert key presses either as they occur, or at maximum rate. The MAX7348/MAX7349 feature a tone generator to generate automatic key-click sounds or alarm tones under processor control. The sounder frequencies cover the 5th musical octave (523.25Hz to 987.77Hz), plus seven other musical notes up to 2637Hz. The output can also be programmed to be high or low for the sound duration to operate an electronic sounder, relay, or lamp. The MAX7347/MAX7348 are offered in 16-pin QSOP and 20-pin QSOP packages, respectively. The MAX7349 is available in 24-pin QSOP and 24-pin SO packages. The MAX7347/MAX7348/MAX7349 operate over the -40C to +125C temperature range. I2C 2.4V to 3.6V Operation Monitor Up to 64 Keys (MAX7349AEG, MAX7349WG), 40 Keys (MAX7348AEP), or 24 Keys (MAX7347AEE) FIFO Queues Up to 8 Debounced Key Events Key Debounce Time User Configurable from 9ms to 40ms Key Autorepeat Rate and Delay User Configurable Low-EMI Design Uses Static Matrix Monitoring Hardware Interrupt on Each Debounced Event or FIFO Level, or at End of Definable Time Period Up to Six Open-Drain Logic Outputs Available Capable of Driving LEDs Sounder Output Generates Automatic Key Clicks 14 Programmable Musical Sounder Frequencies Continuous or Programmable Sounder Duration Easy Automatic Single-Tone and Dual-Tone Alarm Sound Generation Four I2C Address Choices Selectable 2-Wire Serial Bus Timeout Under 10A Shutdown Current Features 400kbps, 5.5V Tolerant 2-Wire Serial Interface MAX7347/MAX7348/MAX7349 Applications Medical Instruments Instrumentation Panels Security and Access Industrial Controls Pin Configurations appear at end of data sheet. Ordering Information PART MAX7347AEE MAX7348AEP TEMP RANGE -40C to +125C -40C to +125C -40C to +125C -40C to +125C PIN-PACKAGE 16 QSOP 20 QSOP 24 QSOP 24 SO Wide Typical Application Circuit INPUT 2.4V TO 3.6V V+ MAX7349 COL_ 8 SWITCH ARRAY, UP TO 64 SWITCHES MAX7349AEG MAX7349AWG 8 ROW_ SCL SDA ALERT INT AD0 GND SOUNDER PIEZO TRANSDUCER Purchase of I2C components from Maxim Integrated Products, Inc., or one of its sublicensed Associated Companies, conveys a license under the Philips I2C Patent Rights to use these components in an I2C system, provided that the system conforms to the I2C Standard Specification as defined by Philips. ________________________________________________________________ Maxim Integrated Products 1 For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim's website at www.maxim-ic.com. 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 ABSOLUTE MAXIMUM RATINGS All voltages referenced to GND. V+ ............................................................................-0.3V to +4V COL2/PORT2-COL7/PORT7 ....................................-0.3V to +4V SDA, SCL, AD0, ALERT, INT ....................................-0.3V to +6V All Other Pins................................................-0.3V to (V+ + 0.3V) DC Current on COL2/PORT2-COL7/PORT7 ......................25mA DC Current on SOUNDER ................................................25mA GND Current .......................................................................80mA Continuous Power Dissipation (TA = +70C) 16-Pin QSOP (derate 8.3mW/C above +70C)...........666mW 20-Pin QSOP (derate 9.1mW/C above +70C)...........727mW 24-Pin QSOP (derate 9.5mW/C above +70C)...........761mW 24-Pin SO (derate 11.8mW/C above +70C)..............941mW Operating Temperature Range (TMIN to TMAX) ...-40C to +125C Junction Temperature ......................................................+150C Storage Temperature Range .............................-65C to +150C Lead Temperature (soldering, 10s) .................................+300C Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ELECTRICAL CHARACTERISTICS (V+ = 2.4V to 3.6V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at V+ = 3.3V, TA = +25C.) (Notes 1, 2) PARAMETER Operating Supply Voltage Operating Supply Current Shutdown Supply Current SOUNDER Output High Voltage SOUNDER Output Low Voltage SOUNDER Frequency Accuracy Key-Switch Source Current Key-Switch Source Voltage Key-Switch Resistance Startup Time from Shutdown Output Low Voltage COL2/PORT2 to COL7/PORT7, INT Output Input Leakage Current Alert Input High Voltage ALERT Input Low Voltage ALERT Serial Bus Timeout Input High Voltage SDA, SCL, AD0 Input Low Voltage SDA, SCL, AD0 Input Leakage Current SDA, SCL, AD0 VIH VIL tOUT VIH VIL Input voltage V+ Input voltage > V+ -1 -5 With bus timeout enabled 20 2.2 0.6 +1 +5 IKEY VKEY RKEY tSTART VOLPORT ISINK = 10mA Input voltage V+ Input voltage > V+ -1 -5 2.2 0.8 68 (Note 3) 57 SYMBOL V+ I+ ISH VOHBUZ VOLBUZ ISOURCE = 10mA ISINK = 10mA TA = +25C, V+ = 3.3V 28 0.35 V+ 0.45 0.15 0.9 40 0.65 5 200 0.15 +1 +5 All key switches open CONDITIONS MIN 2.4 75 6.44 TYP MAX 3.6 100 10 UNITS V A A V V % A V k s V A V V ms V V A SERIAL INTERFACE SPECIFICATIONS 2 _______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers I2C TIMING CHARACTERISTICS (V+ = 2.4V to 3.6V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at V+ = 3.3V, TA = +25C.) (Notes 1, 2) PARAMETER Input Capacitance (SCL, SDA, AD0) SCL Serial Clock Frequency Bus Free Time Between a STOP and a START Condition Hold Time (Repeated) START Condition Repeated START Condition Setup Time STOP Condition Setup Time Data Hold Time Data Setup Time SCL Clock Low Period SCL Clock High Period Rise Time of Both SDA and SCL Signals, Receiving Fall Time of Both SDA and SCL Signals, Receiving Fall Time of SDA Transmitting Pulse Width of Spike Suppressed Capacitive Load for Each Bus Line SYMBOL CIN fSCL tBUF tHD, STA tSU, STA tSU, STO tHD, DAT tSU, DAT tLOW tHIGH tR tF tF.TX tSP Cb (Notes 3, 4) (Notes 3, 4) (Notes 3, 6) (Notes 3, 7) (Note 3) (Note 5) 100 1.3 0.7 20 + 0.1Cb 20 + 0.1Cb 20 + 0.1Cb 300 300 250 50 400 (Notes 3, 4) With bus timeout enabled With bus timeout disabled 0.05 0 1.3 0.6 0.6 0.6 0.9 CONDITIONS MIN TYP MAX 10 400 400 UNITS pF kHz s s s s s ns s s ns ns ns ns pF MAX7347/MAX7348/MAX7349 Note 1: Note 2: Note 3: Note 4: Note 5: All parameters are tested at TA = +25C. Specifications over temperature are guaranteed by design. All digital inputs at V+ or GND. Guaranteed by design. Cb = total capacitance of one bus line in pF. tR and tF measured between 0.8V and 2.1V. A master device must provide a hold time of at least 300ns for the SDA signal (referred to VIL of the SCL signal) to bridge the undefined region of SCL's falling edge. Note 6: ISINK 6mA. Cb = total capacitance of one bus line in pF. tR and tF measured between 0.8V and 2.1V. Note 7: Input filters on the SDA, SCL, and AD0 inputs suppress noise spikes less than 50ns. _______________________________________________________________________________________ 3 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Typical Operating Characteristics (V+ = 3.3V, TA = +25C, unless otherwise noted. Supply range for V+ is 2.4V to 3.6V. Temperature range is -40C to +125C.) GPO OUTPUT LOW VOLTAGE vs. SINK CURRENT MAX7347 toc01 GPO OUTPUT LOW VOLTAGE vs. SINK CURRENT MAX7347 toc02 GPO OUTPUT LOW VOLTAGE vs. SINK CURRENT V+ = 3.6V MAX7347 toc03 300 250 200 VOL (mV) 150 100 50 0 0 V+ = 2.4V 300 250 200 VOL (mV) V+ = 3V 300 250 200 VOL (V) TA = +125C TA = +125C 150 100 TA = -40C 50 0 TA = +25C TA = +125C 150 100 50 0 TA = -40C TA = +25C TA = -40C TA = +25C 5 10 15 20 25 0 5 10 15 20 25 0 5 10 15 20 25 ISINK (mA) ISINK (mA) ISINK (mA) SUPPLY CURRENT vs. SUPPLY VOLTAGE MAX7347 toc04 KEY-SWITCH SOURCE CURRENT vs. SUPPLY VOLTAGE MAX7347 toc05 SOUNDER FREQUENCY vs. SUPPLY VOLTAGE SOUNDER FREQUENCY CONFIGURED FOR 880Hz MAX7347 toc06 90 85 80 SUPPLY CURRENT (A) 75 70 65 60 55 50 45 40 2.4 2.6 2.8 3.0 3.2 3.4 TA = -40C TA = +125C TA = +25C 30 KEY-SWITCH SOURCE CURRENT (A) 29 COL0 = GND TA = -40C 886 884 SOUNDER FREQUENCY (Hz) 882 880 878 876 874 28 27 TA = +25C 26 25 24 TA = +125C TA = -40C TA = +25C TA = +125C 3.6 2.4 2.6 2.8 3.0 3.2 3.4 3.6 2.4 2.7 3.0 3.3 3.6 SUPPLY VOLTAGE (V) SUPPLY VOLTAGE (V) SUPPLY VOLTAGE (V) SOUNDER OUTPUT MAX7347 toc07 OSCILLATOR FREQUENCY vs. SUPPLY VOLTAGE MAX7347 toc08 OSCILLATOR FREQUENCY vs. TEMPERATURE MAX7347 toc09 65 OSCILLATOR FREQUENCY (kHz) 65 OSCILLATOR FREQUENCY (kHz) 64 64 3V VSOUNDER 1V/div 0V 63 63 62 62 61 61 60 200s/div 2.4 2.7 3.0 3.3 3.6 SUPPLY VOLTAGE (V) 60 -40 10 60 110 TEMPERATURE (C) 4 _______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers Pin Description PIN MAX7347 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 -- -- -- MAX7348 1 2 3 4 7 8 9 10 11 12 13 15 17 18 19 20 5 6 14 MAX7349 2 3 4 5 8 9 10 11 14 15 16 18 20 21 22 23 6 7 17 NAME ROW0 ROW1 ROW2 ROW3 ROW4 ROW5 ROW6 ROW7 COL2/PORT2 COL1 COL0 GND SDA SCL INT V+ COL3/PORT3 COL4/PORT4 SOUNDER FUNCTION Row Input from Key Matrix. Leave open circuit if unused. Row Input from Key Matrix. Leave open circuit if unused. Row Input from Key Matrix. Leave open circuit if unused. Row Input from Key Matrix. Leave open circuit if unused. Row Input from Key Matrix. Leave open circuit if unused. Row Input from Key Matrix. Leave open circuit if unused. Row Input from Key Matrix. Leave open circuit if unused. Row Input from Key Matrix. Leave open circuit if unused. Column Output to Key Matrix or GPO Column Output to Key Matrix Column Output to Key Matrix Ground I2C-Compatible Serial Data I/O I2C-Compatible Serial Clock Input Active-Low Interrupt Output. Output is open drain. Positive Supply Voltage. Bypass V+ to GND with a 0.047F or higher ceramic capacitor. Column Output to Key Matrix or GPO Column Output to Key Matrix or GPO Sounder Driver Output. Typically connect a piezo-ceramic sounder or other transducer from this output to ground. Output is push-pull. Address Input 0. Sets device slave address. Connect to GND, V+, SDA, or SCL to give four logic combinations. See Table 3. Column Output to Key Matrix or GPO Column Output to Key Matrix or GPO Column Output to Key Matrix or GPO Alert Input. Connect to GND or V+ if unused. MAX7347/MAX7348/MAX7349 -- -- -- -- -- 16 -- -- -- -- 19 1 12 13 24 AD0 COL7/PORT7 COL6/PORT6 COL5/PORT5 ALERT Detailed Description The MAX7347/MAX7348/MAX7349 are microprocessor peripherals that combine a low-noise key-switch interface with a piezo sounder controller. Up to 64 key switches can be monitored and debounced with optional autorepeat, and the key events are presented in an eight-deep FIFO. Key-switch functionality can be traded to provide up to one (MAX7347), three (MAX7348), or six (MAX7349) open-drain logic outputs. (Table 1). The piezo sounder controller generates a variety of audio tones. Tones are programmable for frequency and duration, and may be intermittent, two tone, or continuous. The piezo sounder controller can be configured to deliver an automatic, customizable sound on every key press to provide audible key-click feedback. Interrupt requests can be configured to be issued on every key-press event, or can be limited to a maximum rate to prevent overloading the microprocessor with too many interrupts. The key-switch status can be checked at any time by reading the key-switch FIFO. 5 _______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 1. Product Features Table PART PACKAGEPINS 24 20 16 MAXIMUM KEY SWITCHES 64 40 24 INT OUTPUT Yes Yes Yes KEYSCAN SLAVE IDs 4 4 1 fixed SOUNDER SLAVE IDs 4 4 -- SOUNDER OUTPUT Yes Yes -- GPOs ALERT INPUT Yes -- -- MAX7349 MAX7348 MAX7347 6 + 1 (INT) 3 + 1 (INT) 1 + 1 (INT) A 1-byte read access returns both the first key-press event in the FIFO (if there is one) and the FIFO status, so it is easy to operate the MAX7347/MAX7348/ MAX7349 by polling. If the INT pin is not required, it can be configured as an open-drain general-purpose output (GPO) capable of driving an LED. The MAX7349 monitors up to 64 keys. The MAX7348 monitors up to 40 keys. The MAX7347 monitors up to 24 keys (Table 1). If the application requires fewer keys to be scanned, up to six of the key-switch outputs can be configured as open-drain GPOs capable of driving LEDs. For each key-switch output used as a GPO, the number of key switches that can be scanned is reduced by eight. An alert logic input (MAX7349 only) can be configured to deliver an automatic, customizable sound and/or an interrupt on every falling edge of the logic input. The logic state of the alert input can be read at any time. Key-Scan Controller Key inputs are scanned statically, not dynamically, to ensure low-EMI operation. As inputs only toggle in response to switch changes, the key matrix can be routed closer to sensitive circuit nodes. The key controller debounces and maintains a FIFO of key-press events (including autorepeated key presses, if autorepeat is enabled). Figure 1 shows keys order. Serial Interface Figure 2 shows the 2-wire serial interface timing details. Serial Addressing The MAX7347/MAX7348/MAX7349 operate as slaves that send and receive data through an I2C-compatible 2-wire interface. The interface uses a serial data line (SDA) and a serial clock line (SCL) to achieve bidirectional communication between master(s) and slave(s). A master (typically a microcontroller) initiates all data transfers to and from the MAX7347/MAX7348/MAX7349 and generates the SCL clock that synchronizes the data transfer. The MAX7347/MAX7348/MAX7349s' SDA line operates as both an input and an open-drain output. A pullup resistor, typically 4.7k, is required on SDA. The MAX7347/MAX7348/MAX7349s' SCL line operates only as an input. A pullup resistor, typically 4.7k, is required on SCL if there are multiple masters on the 2-wire interface, or if the master in a single-master system has an open-drain SCL output. Each transmission consists of a START condition (Figure 3) sent by a master, followed by the MAX7347/ MAX7348/MAX7349 7-bit slave address plus R/W bit, a register address byte, 1 or more data bytes, and finally a STOP condition. Tone Generator The piezo sounder controller generates a square wave with the frequency of a musical tone under processor control. The selection of tones covers the 5th musical octave (523.25Hz to 987.77Hz), plus seven other notes up to 2637Hz. The sounder output is also programmable to be either high or low for the entire sound duration to operate an electronic sounder, relay, or lamp instead of a piezo transducer. The sound duration is programmable from 15.625ms in seven binary steps up to a maximum of 1s. The piezo sounder controller interface uses a single 1byte access to its own separate slave address. Commands are double-buffered to allow two commands (2 bytes) to be stored and executed in succession. The sounder controller performs the transition between queued sound commands without click artifacts. The controller can also autoloop between the two most recent commands. Autolooping allows a wide range of intermittent and two-tone sounds to be initiated, and then run automatically without further intervention. Start and Stop Conditions Both SCL and SDA remain high when the interface is not busy. A master signals the beginning of a transmission with a START (S) condition by transitioning SDA from high to low while SCL is high. When the master 6 _______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 *MAX7348 AND MAX7349 ONLY. **MAX7349 ONLY. KEY 0 COL7/PORT7** COL6/PORT6** COL5/PORT5** COL4/PORT4* COL3/PORT3* COL2/PORT2 COL1 COL0 ROW0 ROW1 ROW2 ROW3 ROW4 ROW5 ROW6 ROW7 KEY 4 KEY 3 KEY 2 KEY 1 KEY 8 KEY 16 KEY 24 KEY 32 KEY 40 KEY 48 KEY 56 KEY 9 KEY 17 KEY 25 KEY 33 KEY 41 KEY 49 KEY 57 KEY 10 KEY 18 KEY 26 KEY 34 KEY 42 KEY 50 KEY 58 KEY 11 KEY 19 KEY 27 KEY 35 KEY 43 KEY 51 KEY 59 KEY 12 KEY 20 KEY 28 KEY 36 KEY 44 KEY 52 KEY 60 KEY 5 KEY 13 KEY 21 KEY 29 KEY 37 KEY 45 KEY 53 KEY 61 KEY 6 KEY 14 KEY 22 KEY 30 KEY 38 KEY 46 KEY 54 KEY 62 KEY 7 KEY 15 KEY 23 KEY 31 KEY 39 KEY 47 KEY 55 KEY 63 Figure 1. Keys Order has finished communicating with the slave, it issues a STOP (P) condition by transitioning SDA from low to high while SCL is high. The bus is then free for another transmission. Bit Transfer One data bit is transferred during each clock pulse (Figure 4). The data on SDA must remain stable while SCL is high. Acknowledge The acknowledge bit is a clocked 9th bit (Figure 5), which the recipient uses to handshake receipt of each byte of data. Thus, each byte transferred effectively requires 9 bits. The master generates the 9th clock pulse, and the recipient pulls down SDA during the acknowledge clock pulse, so the SDA line is stable low during the high period of the clock pulse. When the master is transmitting to the MAX7347/MAX7348/ MAX7349, the MAX7347/MAX7348/MAX7349 generate the acknowledge bit because the MAX7347/MAX7348/ MAX7349 are the recipients. When the MAX7347/ MAX7348/MAX7349 are transmitting to the master, the master generates the acknowledge bit because the master is the recipient. _______________________________________________________________________________________ 7 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 SDA tSU, DAT tLOW tHIGH tHD, STA tR START CONDITION tF REPEATED START CONDITION STOP CONDITION START CONDITION tHD, DAT tBUF tHD, STA tSU, STO tSU, STA SCL Figure 2. 2-Wire Serial Interface Timing Details SDA SCL S START CONDITION P STOP CONDITION Figure 3. Start and Stop Conditions SDA SCL DATA LINE STABLE; DATA VALID CHANGE OF DATA ALLOWED Figure 4. Bit Transfer 8 _______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 2. Key-Switch Mapping PIN ROW0 ROW1 ROW2 ROW3 ROW4 ROW5 ROW6 ROW7 COL0 KEY 0 KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 KEY 6 KEY 7 COL1 KEY 8 KEY 9 KEY 10 KEY 11 KEY 12 KEY 13 KEY 14 KEY 15 COL2/PORT2 COL3/PORT3 COL4/PORT4 COL5/PORT5 COL6/PORT6 COL7/PORT7 KEY 16 KEY 17 KEY 18 KEY 19 KEY 20 KEY 21 KEY 22 KEY 23 KEY 24 KEY 25 KEY 26 KEY 27 KEY 28 KEY 29 KEY 30 KEY 31 KEY 32 KEY 33 KEY 34 KEY 35 KEY 36 KEY 37 KEY 38 KEY 39 KEY 40 KEY 41 KEY 42 KEY 43 KEY 44 KEY 45 KEY 46 KEY 47 KEY 48 KEY 49 KEY 50 KEY 51 KEY 52 KEY 53 KEY 54 KEY 55 KEY 56 KEY 57 KEY 58 KEY 59 KEY 60 KEY 61 KEY 62 KEY 63 Table 3. 2-Wire Interface Address Map PIN AD0 DEVICE ADDRESS A7 A6 A5 A4 A3 A2 A1 0 GND 0 1 1 1 0 0 1 0 V+ 0 1 1 1 0 1 1 0 SDA 0 1 1 1 1 0 1 0 SCL 0 1 1 1 1 1 1 A0 R/W 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 FUNCTION Key-scan controller write Key-scan controller read Sounder controller write Sounder controller read Key-scan controller write Key-scan controller read Sounder controller write Sounder controller read Key-scan controller write Key-scan controller read Sounder controller write Sounder controller read Key-scan controller write Key-scan controller read Sounder controller write Sounder controller read Slave Addresses The MAX7347/MAX7348/MAX7349 have two 7-bit long slave addresses (Figure 6). The bit following a 7-bit slave address is the R/W bit, which is low for a write command and high for a read command. The first 4 bits (MSBs) of the MAX7347/MAX7348/ MAX7349 slave addresses are always 0111. Slave address bits A3, A2, and A1 correspond, by the matrix in Table 3, to the states of the device address input AD0, and A0 corresponds to the R/W bit. MAX7347/ MAX7348/MAX7349 use two slave addresses, one for the main key-scan controller, and one for the sounder controller. The AD0 input can be connected to any of four signals: GND, V+, SDA, or SCL, giving four possible slave address pairs, allowing up to four MAX7347/ MAX7348/MAX7349 devices to share the bus. Only one MAX7347 can share the bus. The MAX7347 AD0 input is internally connected to GND. The MAX7347/MAX7348/MAX7349 monitor the bus continuously, waiting for a START condition followed by its slave address. When MAX7347/MAX7348/MAX7349 recognize their slave address, they acknowledge and are then ready for continued communication. _______________________________________________________________________________________ 9 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 START CONDITION CLOCK PULSE FOR ACKNOWLEDGE 1 2 8 9 SCL SDA BY TRANSMITTER SDA BY RECEIVER S Figure 5. Acknowledge SDA SCL 0 MSB 1 1 1 A3 A2 A1 LSB R/W ACK Figure 6. Slave Address Bus Timeout The MAX7347/MAX7348/MAX7349 feature a 20ms minimum bus timeout on the 2-wire serial interface, largely to prevent the MAX7347/MAX7348/MAX7349 from holding the SDA I/O low during a read transaction if the SCL hangs for any reason before a serial transaction has been completed. Bus timeout operates by causing the MAX7347/MAX7348/MAX7349 to internally terminate a serial transaction, either read or write, if the time between adjacent edges on SCL exceeds 20ms. After a bus timeout, the MAX7347/MAX7348/MAX7349 wait for a valid START condition before responding to a consecutive transmission. The bus timeout feature requires the serial interface to operate above 50Hz bus speed. This feature can be enabled or disabled under user control by writing to the configuration register (Table 12). Any bytes received after the command byte are data bytes. The first data byte goes into the internal register of the MAX7347/MAX7348/MAX7349 selected by the command byte (Figure 8). If multiple data bytes are transmitted before a STOP condition is detected, these bytes are generally stored in subsequent MAX7347/MAX7348/MAX7349 internal registers (Table 7) because the command byte address generally autoincrements (Table 4). Message Format for Reading the Key-Scan Controller The MAX7347/MAX7348/MAX7349 are read using the MAX7347/MAX7348/MAX7349s' internally stored command byte as an address pointer, the same way the stored command byte is used as an address pointer for a write. The pointer generally autoincrements after each data byte is read using the same rules as for a write (Table 4). Thus, a read is initiated by first configuring the MAX7347/MAX7348/MAX7349s' command byte by performing a write (Figure 7). The master can now read n consecutive bytes from the MAX7347/MAX7348/ MAX7349, with the first data byte being read from the register addressed by the initialized command byte. When performing read-after-write verification, remember to reset the command byte's address because the stored command byte address is generally autoincremented after the write (Figure 9, Table 4). Message Format for Writing the Key-Scan Controller A write to the MAX7347/MAX7348/MAX7349s' key-scan controller comprises the transmission of the MAX7347/MAX7348/MAX7349s' key-scan slave address with the R/W bit set to zero, followed by at least 1 byte of information. The first byte of information is the command byte. The command byte determines which register of the MAX7347/MAX7348/MAX7349 is to be written by the next byte, if received. If a STOP condition is detected after the command byte is received, then the MAX7347/MAX7348 /MAX7349 take no further action (Figure 7) beyond storing the command byte. 10 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 COMMAND BYTE IS STORED ON RECEIPT OF ACKNOWLEDGE CONDITION ACKNOWLEDGE FROM MAX7347/MAX7348/MAX7349 S SLAVE ADDRESS R/W 0 A D7 D6 D5 D4 D3 D2 D1 D0 COMMAND BYTE A P ACKNOWLEDGE FROM MAX7347/MAX7348/MAX7349 Figure 7. Command Byte Received ACKNOWLEDGE FROM MAX7347/MAX7348/MAX7349 D7 ACKNOWLEDGE FROM MAX7347/MAX7348/MAX7349 S SLAVE ADDRESS R/W 0 A COMMAND BYTE D6 D5 D4 D3 D2 D1 D0 ACKNOWLEDGE FROM MAX7347/MAX7348/MAX7349 D7 D6 D5 D4 D3 D2 D1 D0 A DATA BYTE 1 BYTE A P AUTOINCREMENT COMMAND BYTE ADDRESS Figure 8. Command and Single Data Byte Received Message Format for Writing the Sounder Controller A write to the MAX7347/MAX7348/MAX7349s' sounder controller comprises the transmission of the MAX7347/MAX7348/MAX7349s' sounder slave address with the R/W bit set to zero, followed by at least 1 command byte of information. The sounder controller analyzes each incoming data byte, and depending on the state of the sounder controller's 2-deep FIFO and the contents of the command byte, the command byte is added to the FIFO or it overwrites the last FIFO data item (Table 16). Table 4. Key-Scan Command Address Autoincrement Rules REGISTER FUNCTION Keys FIFO Debounce Autorepeat Interrupt Configuration Port Key Sound Alert Sound ADDRESS CODE (hex) 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 AUTOINCREMENT ADDRESS (hex) 0x00 0x02 0x03 0x04 0x05 0x06 0x07 0x00 Message Format for Reading the Sounder Controller A read from the MAX7347/MAX7348/MAX7349s' sounder controller comprises the transmission of the MAX7347/MAX7348/MAX7349s' sounder slave address with the R/W bit set to 1. The master can now read n consecutive bytes from the MAX7347/MAX7348/MAX7349, each byte being a snapshot of the FIFO status of the sounder controller (Table 16). If the master wishes to poll the sounder controller until there is room for another command to be sent, the master can read bytes continuously from the sounder controller until the information is satisfactory and then issue a STOP condition. Operation with Multiple Masters If the MAX7347/MAX7348/MAX7349 are operated on a 2wire interface with multiple masters, a master reading the MAX7347/MAX7348/MAX7349 should use a repeated start between the write that sets the MAX7347/MAX7348/ MAX7349s' address pointer, and the read(s) that takes the data from the location(s). This is because it is possible for master 2 to take over the bus after master 1 has set up the MAX7347/MAX7348/MAX7349s' address pointer but before master 1 has read the data. If master 2 subsequently resets the MAX7347/MAX7348/MAX7349s' address pointer, then master 1's read may be from an unexpected location. 11 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 5. Key-Scan Power-Up Configuration REGISTER FUNCTION Keys FIFO Debounce Autorepeat Interrupt Configuration Ports Key Sound Alert Sound Empty Ports 2-7 are enabled; debounce time is 39ms Autorepeat is disabled INT is a port, not an interrupt output Shutdown mode: key sound is disabled; alert sound is disabled; alert INT is disabled; timeout enabled; no sound output Ports 2-7 and INT are logic-high (high impedance) Key-sound default is 31.25ms of 987.77Hz Key-sound default is 250ms of 2093Hz POWER-UP CONDITION ADDRESS CODE (hex) 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 REGISTER DATA D7 0 1 0 0 0 1 0 1 D6 0 1 0 0 0 1 1 0 D5 0 1 0 0 0 1 0 1 D4 0 1 0 0 0 1 1 1 D3 0 1 0 0 0 1 0 1 D2 0 1 0 0 0 1 0 0 D1 0 1 0 0 0 1 0 1 D0 0 1 0 0 1 X 1 1 X = Don't care. Table 6. Sounder Power-Up Configuration POWER-UP CONDITION Sounder output is a general-purpose output, logic 0; queue is empty REGISTER DATA D7 0 D6 0 D5 0 D4 0 D3 0 D2 0 D1 0 D0 0 ACKNOWLEDGE FROM MAX7347/MAX7348/MAX7349 D7 ACKNOWLEDGE FROM MAX7347/MAX7348/MAX7349 S SLAVE ADDRESS R/W 0 A COMMAND BYTE A D6 D5 D4 D3 D2 D1 D0 ACKNOWLEDGE FROM MAX7347/MAX7348/MAX7349 D7 D6 D5 D4 D3 D2 D1 D0 DATA BYTE N BYTES A P AUTOINCREMENT COMMAND BYTE ADDRESS Figure 9. N Data Bytes Received 12 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 7. Key-Scan Register Address Map REGISTER FUNCTION Keys FIFO Debounce Autorepeat Interrupt Configuration Ports Key Sound Alert Sound COMMAND ADDRESS D15 0 0 0 0 0 0 0 0 D14 0 0 0 0 0 0 0 0 D13 0 0 0 0 0 0 0 0 D12 0 0 0 0 0 0 0 0 D11 0 0 0 0 0 0 0 0 D10 0 0 0 0 1 1 1 1 D9 0 0 1 1 0 0 1 1 D8 0 1 0 1 0 1 0 1 ADDRESS CODE (hex) 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 Table 8. Keys FIFO Register Format REGISTER ADDRESS CODE (hex) 0X00 REGISTER DATA D7 OVERFLOW FLAG D6 MORE FLAG D5 D4 D3 D2 D1 D0 KEYS FIFO REGISTER* KEY SWITCH THAT HAS BEEN DEBOUNCED FIFO has not overflowed FIFO overflowed; FIFO contains the first eight key events 0x00 0x00 0 1 X X X X X X X X X X X X X X This key is the last FIFO item (key-switch data not zero) Key 0 was EITHER the last FIFO item OR the FIFO is empty and no key has been pressed This key is not the last FIFO item Power-up default setting 0x00 0x00 0x00 0x00 X 0 X 0 0 0 1 0 X 0 X 0 X 0 X 0 X 0 X 0 X 0 X 0 X 0 X 0 X 0 X 0 *Reading the key-scan FIFO clears the INT. INT is only reasserted by a key event after the FIFO has been emptied by read(s). Command Address Autoincrementing Address autoincrementing allows the MAX7347/ MAX7348/MAX7349 to be configured with fewer transmissions by minimizing the number of times the command address needs to be sent. The command address stored in the MAX7347/MAX7348/MAX7349 generally increments after each data byte is written or read (Table 4). Autoincrementing applies only to the key-scan command addresses and not to the sounder command addresses. Registers Description Initial Power-Up On power-up, all control registers are reset and the MAX7347/MAX7348/MAX7349 enter shutdown mode (Tables 5, 6). Table 7 shows the register address map for the key-scan section. ______________________________________________________________________________________ 13 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 9. Debounce Register Format REGISTER DEBOUNCE REGISTER Debounce time is 9ms Debounce time is 10ms Debounce time is 11ms Debounce time is 12ms All the way through to Debounce time is 37ms Debounce time is 38ms Debounce time is 39ms Debounce time is 40ms GPO ports disabled (full key-scan functionality) GPO port 7 enabled GPO ports 7 and 6 enabled GPO ports 7, 6, and 5 enabled GPO ports 7, 6, 5, and 4 enabled GPO ports 7, 6, 5, 4, and 3 enabled GPO ports 7, 6, 5, 4, 3, and 2 enabled Power-up default setting ADDRESS CODE (hex) 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 D7 X X X X X X X X X 0 0 0 0 1 1 1 1 D6 X X X X X X X X X 0 0 1 1 0 0 1 1 REGISTER DATA D5 X X X X X X X X X 0 1 0 1 0 1 X 1 D4 0 0 0 0 -- 1 1 1 1 X X X X X X X 1 D3 0 0 0 0 -- 1 1 1 1 X X X X X X X 1 D2 0 0 0 0 -- 1 1 1 1 X X X X X X X 1 D1 0 0 1 1 -- 0 0 1 1 X X X X X X X 1 D0 0 1 0 1 -- 0 1 0 1 X X X X X X X 1 PORTS ENABLE DEBOUNCE TIME Key-Scan Registers Eight key-scan registers are described in the following sections. Keys FIFO Register The keys FIFO register contains the information pertaining to the status of the keys FIFO, as well as the keypress events that have been debounced (Table 8). Bits D0 to D5 denote which of the 64 keys have been debounced and the keys are numbered as in Table 2 and Figure 1. D6 indicates whether the present debounced key is the last one in the FIFO, with 1 denoting that there are more keys after the present one, and 0 denoting that the present debounced key is the last one stored in the FIFO. D7 is the overflow flag, which denotes whether the keys FIFO has overflowed. Reading the key-scan FIFO clears the interrupt INT. INT is only reasserted after the FIFO has been emptied by performing enough read operations. Debounce Register The debounce register sets the time for each debounce cycle, as well as setting whether the GPO ports are enabled or disabled. Bits D0 through D4 set the debounce time in increments of 1ms starting at 9ms and ending at 40ms (Table 9). Bits D5 through D7 set which one of the GPO ports is to be enabled. Note that not any port can be enabled at a particular time. The GPO ports can be enabled only in the combinations shown in Table 9, from all disabled to all enabled. Autorepeat Register The autorepeat register sets the autorepeat frequency (repeat rate) and its delay. The autorepeat function allows a key to be consecutively asserted when the key itself is pressed down without being released. The autorepeat delay specifies the delay between the first press and the beginning of the autorepeating, provided that the key has not been released. The autorepeat frequency specifies how fast the continuously pressed-down key to be asserted once autorepeating has started is. Bits D0 through D3 specify the autorepeat delay in terms of debounce cycles 14 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers ranging from 8 debounce cycles to 128 debounce cycles (Table 10). Bits D4 through D6 specify the autorepeat rate or frequency ranging from 4 to 32 debounce cycles. Bit D7 specifies whether the auto-repeat function is enabled with 0 denoting autorepeat disabled and 1 denoting autorepeat enabled. Interrupt Register The interrupt register contains information related to the settings of the interrupt request function, as well as the status of the INT output, which can also be configured as a GPO. Bits D0 through D4 set the key-scan interrupt frequency. By setting bits D0 through D4 to an appropriate value, the interrupt can be asserted at the end of the selected number of debounce cycles (Table 11). This number ranges from 1 to 31 debounce cycles. If bits D0 through D4 are set to 00000, the INT output is configured as a GPO that is controlled by bit D6 in the ports register and the INT output is not asserted. However, the INT status bits D5, D6, and D7 are still set and cleared in the normal way at the end of each debounce cycle as if bits D0 through D4 were set to 00001. Bits D5 and D6 denote whether an interrupt was set due to a key-scan event (bit D5) or to an alert event (bit D6). Bit D7 represents whether an interrupt request has been asserted with 0 denoting no INT asserted and 1 denoting that INT has been asserted. The interrupt register is a read-only register and writes to it are ignored. Reading the interrupt register does clear an alert event INT, but does not clear a key-scan event INT. An interrupt request caused by a key-scan event(s) is cleared when the FIFO is emptied. Configuration Register The configuration register reflects the sounder status, controls the I2C bus timeout feature, enables the alert input interrupt feature, enables the sounder to respond to both alert input and key debounce events, and controls the shutdown of the device (Table 12). Ports Register The ports register sets the values of ports 2 through 7 and the INT port when configured as GPOs. The settings in this register are ignored for ports not configured as GPOs, and a read from this register returns the values stored in the register and not the actual port conditions (Table 13). The ports register also serves to read the alert input and this is done through bit D0 with a 0 denoting a low on the alert input and a 1 denoting a high. Key-Sound Register The key-sound register specifies the duration and frequency of the sound to be executed by the sounder controller when a key or a set of keys are debounced if the sounder output has been enabled to be set by a key debounce event in the configuration register. When this happens, the information of bits D7 through D1 is passed on to the sounder register and the appropriate sound is executed (Tables 14, 16). Least significant bit D0 is ignored and always set to 1 when transferred to the sounder register. See Table 16 for the format of setting the frequency and duration of the sound to be executed. If a key-sound register command is sent as 000xxxx (continuous), then the command is stored as 111xxxx (1000ms) in the sounder register. Alert Sound Register The alert sound register specifies the duration and frequency of the sound to be executed by the sounder controller at the falling edge of the alert input if the sounder output has been enabled to be set by the alert input in the configuration register. If this is the case, the information of bits D7 through D1 is passed on to the sounder register and the appropriate sound is executed (Tables 15, 16). Least significant bit D0 is always set to 1 and this value is ignored when transferred to the sounder register. See Table 16 for the proper format of setting the frequency and duration of the sound to be executed. Note that if an alert sound register command is sent as 000xxxx (continuous), then the command is actually stored as 111xxxx (1000ms) in the sounder register. Sounder Register The sounder register stores the frequencies and duration of the sounds to be executed by the sounder, as well as the state of its two-deep FIFO (Table 16). D0 denotes whether another command is lined in the queue at any given moment. A 0 in D0 denotes that the queue is empty while a 1 denotes that there is another command. By writing 0 to D0, the present command is executed and the queue is cleared. When sending a command that has a D0 set to 1, the queue is checked and, if empty, the sent command is added to it while, if full, the sent command replaces the queued command. Bits D0 and D1, when taken in conjunction, set the level of the sounder output when configured as a GPO and also control the autoloop function provided that the rest of the bits (D7 through D2) are set to 0. When the sounder is configured as a GPO, the levels of the output are set by D1, a 0 denoting a low and a 1 denoting a high. When D0 is set to 1 and the rest of the bits are set to 0, D1 controls the autoloop function as defined in Table 16. Bits D7 through D1 control the frequency and duration of the sounds to be executed by the sounder. These sounds include the musical notes of the 5th octave plus some notes from the 6th and 7th octaves as well. See Table 16. MAX7347/MAX7348/MAX7349 ______________________________________________________________________________________ 15 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 10. Autorepeat Register Format REGISTER ADDRESS CODE (hex) 0x02 REGISTER DATA D7 ENABLE D6 D5 D4 D3 D2 D1 D0 AUTOREPEAT REGISTER AUTOREPEAT RATE X X X AUTOREPEAT DELAY Autorepeat is disabled Autorepeat is enabled 0x02 0x02 0 1 X X X X AUTOREPEAT RATE X X X X X X X X X X X X X X X X 0 0 0 0 1 1 1 1 0 X X X X X X X X X X X X X X X X 0 0 1 1 0 0 1 1 0 X X X X X X X X X X X X X X X X 0 1 0 1 0 1 0 1 0 AUTOREPEAT DELAY Key-switch autorepeat delay is 8 debounce cycles Key-switch autorepeat delay is 16 debounce cycles Key-switch autorepeat delay is 24 debounce cycles Key-switch autorepeat delay is 32 debounce cycles Key-switch autorepeat delay is 40 debounce cycles Key-switch autorepeat delay is 48 debounce cycles Key-switch autorepeat delay is 56 debounce cycles Key-switch autorepeat delay is 64 debounce cycles Key-switch autorepeat delay is 72 debounce cycles Key-switch autorepeat delay is 80 debounce cycles Key-switch autorepeat delay is 88 debounce cycles Key-switch autorepeat delay is 96 debounce cycles Key-switch autorepeat delay is 104 debounce cycles Key-switch autorepeat delay is 112 debounce cycles Key-switch autorepeat delay is 120 debounce cycles Key-switch autorepeat delay is 128 debounce cycles Key-switch autorepeat frequency is 4 debounce cycles Key-switch autorepeat frequency is 8 debounce cycles Key-switch autorepeat frequency is 12 debounce cycles Key-switch autorepeat frequency is 16 debounce cycles Key-switch autorepeat frequency is 20 debounce cycles Key-switch autorepeat frequency is 24 debounce cycles Key-switch autorepeat frequency is 28 debounce cycles Key switch autorepeat frequency is 32 debounce cycles Power-up default setting 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 0x02 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 X X X X X X X X 0 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 X X X X X X X X 0 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 X X X X X X X X 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 X X X X X X X X 0 16 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 11. Interrupt Register Format REGISTER ADDRESS CODE (hex) REGISTER DATA D7 INT STATUS* D6 ALERT EVENT* D5 KEYSCAN EVENT* 1 0 1 0 KEYSCAN EVENT D4 D3 D2 D1 D0 INTERRUPT REGISTER 0x03 KEY-SCAN INTERRUPT FREQUENCY Current INT is due to key-scan event(s) Current INT is due to alert event Current INT is due to both key-scan event(s) and alert event INT has not been asserted INT has been asserted 0x03 0x03 0x03 0x03 0x03 1 1 1 0 1 0 1 1 0 ALERT EVENT X X X X X X X X X X X X X X X X X X X X X X X X X INT output pin is NOT asserted; INT output pin is used as a general-purpose output called INT port under control of bit D6 in ports register; INT status bits D5, D6, D7 are still set and cleared in the normal way at the end of every debounce cycle as if bits D4-D0 were set to 00001 Key-scan INT is asserted at the end of every debounce cycle, if new key(s) is debounced Key-scan INT is asserted at the end of every 2 debounce cycles, if new key(s) is debounced --- Key-scan INT is asserted at the end of every 29 debounce cycles, if new key(s) is debounced Key-scan INT is asserted at the end of every 30 debounce cycles, if new key(s) is debounced Key-scan INT is asserted at the end of every 31 debounce cycles, if new key(s) is debounced Power-up default setting 0x03 X X X 0 0 0 0 0 0x03 X X X 0 0 0 0 1 0x03 X -- X -- X X -- X 0 -- 1 0 -- 1 0 -- 1 1 -- 0 0 -- 1 0x03 X 0x03 X X X 1 1 1 1 0 0x03 0x03 X 0 X 0 X 0 1 0 1 0 1 0 1 0 1 0 *Read-only register bits; write data is ignored. Reading the interrupt register does clear an alert event INT, but does not clear a keyscan event INT. INT caused by key-scan event(s) is cleared when FIFO is emptied. ______________________________________________________________________________________ 17 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 12. Configuration Register Format REGISTER ADDRESS CODE (hex) 0x04 0x04 0x04 0x04 0x04 0x04 0x04 REGISTER DATA D7 SHUTDOWN X X X X X X D6 D5 D4 D3 D2 D1 D0 CONFIGURATION REGISTER Serial interface bus timeout enabled Serial interface bus timeout disabled No active sounder output Active sounder output set by serial interface Active sounder output set by key debounce event Active sounder output set by an alert event KEY ALERT ALERT ALERT SOUNDER TIMEOUT SOUND SOUND INT INT STATUS ENABLE ENABLE ENABLE ENABLE EVENT X X X X X X X X X X X X X X X X X X X X X X X X X X 0 0 1 1 X X 0 1 0 1 0 1 X X X X Alert input interrupt (if enabled) is asserted according to key-scan interrupt rules Alert input interrupt (if enabled) is asserted immediately 0x04 X X X X 0 X X X 0x04 X X X X 1 X X X Alert input does not cause an interrupt Falling edge of alert input causes interrupt 0x04 0x04 X X X X X X 0 1 X X X X X X X X Alert input does not cause an automatic sound Falling edge of alert input causes the 8-bit contents of the alert sound register 0x07 to be sent to the sounder 0x04 X X 0 X X X X X 0x04 X X 1 X X X X X Debounce key(s) do not cause an automatic sound Debounced key(s), including autorepeated keys, cause the 8-bit contents of the key-sound register 0x06 to be sent to the sounder 0x04 X 0 X X X X X X 0x04 X 1 X X X X X X 18 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 12. Configuration Register Format (continued) REGISTER ADDRESS CODE (hex) 0x04 REGISTER DATA D7 SHUTDOWN D6 D5 D4 D3 D2 D1 D0 CONFIGURATION REGISTER Shutdown mode; key-scan and sounder timing are disabled, interrupts disabled, but alert input can be read and port outputs (as selected) can be changed Operating mode; key scan is started, and commands in sounder queue are actioned Power-up default setting KEY ALERT ALERT ALERT SOUNDER TIMEOUT SOUND SOUND INT INT STATUS ENABLE ENABLE ENABLE ENABLE EVENT 0x04 0 X X X X X X X 0x04 0x04 1 0 X 0 X 0 X 0 X 0 X 0 X 0 X 1 Table 13. Ports Register Format REGISTER ADDRESS CODE (hex) READ WRITE READ PORTS REGISTER 0x05 WRITE PORT 7 PORT 6 PORT 5 PORT 4 PORT 3 PORT 2 REGISTER DATA D7 D6 D5 D4 D3 D2 D1 INT PORT INT PORT X X X X X X X X X X D0 ALERT INPUT X PORT 7 PORT 6 PORT 5 PORT 4 PORT 3 PORT 2 Clear port 2 low Set port 2 high (high impedance) Clear port 3 low Set port 3 high (high impedance) Clear port 4 low Set port 4 high (high impedance) Clear port 5 low Set port 5 high (high impedance) Clear port 6 low Set port 6 high (high impedance) 0x05 0x05 0x05 0x05 0x05 0x05 0x05 0x05 0x05 0x05 Write Write Write Write Write Write Write Write Write Write X X X X X X X X X X X X X X X X X X 0 1 X X X X X X 0 1 X X X X X X 0 1 X X X X X X 0 1 X X X X X X 0 1 X X X X X X X X X X X X X X X X X X ______________________________________________________________________________________ 19 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 13. Ports Register Format (continued) REGISTER ADDRESS CODE (hex) READ WRITE READ PORTS REGISTER 0x05 WRITE Clear port 7 low Set port 7 high (high impedance) Clear INT port low; this setting is ignored unless the key-scan INT functionality is disabled by setting interrupt register bits D4 to D0 to 00000 Set INT port high (high impedance); this setting is ignored unless the key-scan INT functionality is disabled by setting interrupt register bits D4 to D0 to 00000 Alert input level is low Alert input level is high Power-up default setting 0x05 0x05 Write Write PORT 7 PORT 6 PORT 5 PORT 4 PORT 3 PORT 2 0 1 X X X X X X X X X X REGISTER DATA D7 D6 D5 D4 D3 D2 D1 INT PORT INT PORT X X D0 ALERT INPUT X X X PORT 7 PORT 6 PORT 5 PORT 4 PORT 3 PORT 2 0x05 Write X X X X X X 0 X 0x05 Write X X X X X X 1 X 0x05 0x05 0x05 Read Read -- X X 1 X X 1 X X 1 X X 1 X X 1 X X 1 X X 1 0 1 X Table 14. Key-Sound Register Format REGISTER This-8 bit value is passed to sounder controller when key(s) debounced, if enabled in the configuration register; these 7 bits define duration and frequency only; sounder command bit D0 is ignored and fixed internally at 1; if a key sound is sent as 000xxxxx (continuous), then the command is stored as 111xxxxx (1000 ms) Power-up default setting ADDRESS CODE (hex) REGISTER DATA D7 D6 D5 D4 D3 D2 D1 D0 0x06 7-bit value (see Table 16 for functionality) 1 0x06 0 1 0 1 0 0 0 1 20 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 15. Alert Sound Register Format REGISTER This 8-bit value is passed to sounder controller on the falling edge of the alert input; these 7 bits define duration and frequency only; sounder command bit D0 is ignored and fixed internally at 1; if an alert sound is sent as 000xxxxx (continuous), then the command is stored as 111xxxxx (1000 ms) Power-up default setting ADDRESS CODE (hex) REGISTER DATA D7 D6 D5 D4 D3 D2 D1 D0 0x07 7-bit value (see Table 16 for functionality) 1 0x07 1 0 1 1 1 0 1 1 Table 16. Sounder Register Format REGISTER SOUNDER REGISTER No commands are active; OR output is GPO logic 0 This current command is active, none are queued (so another command may be sent) This current command is active, and another command is in the queue Read Read Read REGISTER DATA READ WRITE D7 D6 D5 D4 D3 D2 D1 D0 DURATION 0 0 0 FREQUENCY 0 0 0 LEVEL BUFFER 0 LEVEL LEVEL 0 0 1 DURATION DURATION FREQUENCY FREQUENCY Perform this command, terminating and clearing any previous active command, command queue, and autoloop; new command is now active, and queue is now empty Add command to queue if not full; command replaces queued command if queue is full Write X X X X X X X 0 Write X X X X X X X 1 Configure sounder output as general-purpose output, logic 0 (clear queue; sounder output active low with continuous duration, ie, until a buffer = 0 command) Configure sounder output as general-purpose output, logic 1 (clear queue; sounder output active high with continuous duration, ie, until a buffer = 0 command) Autoloop using the current two commands; the active command is command 1, and the inactive command is command 2; if no command is active, the oldest command is reactivated as command 1, and the other command is reactivated as command 2 Autoloop is halted at the end of command 2, and output idles as defined by command 2 Write 0 0 0 0 0 0 0 0 Write 0 0 0 0 0 0 1 0 Write 0 0 0 0 0 0 0 1 Write 0 0 0 0 0 0 1 1 ______________________________________________________________________________________ 21 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Table 16. Sounder Register Format (continued) REGISTER SOUNDER REGISTER Sounder output active low for sound duration; queue cleared Sounder output active high for sound duration; queue cleared Sound frequency is 523.25Hz, idles low Sound frequency is 587.33Hz, idles low Sound frequency is 659.26, idles low Sound frequency is 698.46Hz, idles low Sound frequency is 783.99Hz, idles low Sound frequency is 880Hz, idles low Sound frequency is 987.77Hz, idles low Sound frequency is 1046.5Hz, idles low Sound frequency is 1318.5Hz, idles low Sound frequency is 1568Hz, idles low Sound frequency is 1760Hz, idles low Sound frequency is 2093Hz, idles low Sound frequency is 2349.3Hz, idles low Sound frequency is 2637Hz, idles low Sound duration is continuous; if an alert sound or a key sound is programmed as 000xxxxx (continuous), then the command is treated as 111xxxxx (1000 ms) Sound duration is 15625ms* Sound duration is 3125ms* Sound duration is 625ms* Sound duration is 125ms* Sound duration is 250ms* Sound duration is 500ms* Sound duration is 1000ms* Power-up default setting REGISTER DATA READ WRITE D7 D6 D5 D4 D3 D2 D1 D0 DURATION FREQUENCY LEVEL BUFFER -- -- Note C5 Note D5 Note E5 Note F5 Note G5 Note A5 Note B5 Note C6 Note E6 Note G6 Note A6 Note C7 Note D7 Note E7 Write Write Write Write Write Write Write Write Write Write Write Write Write Write Write Write DURATION 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 BUFFER Write Write Write Write Write Write Write Write -- 0 0 0 0 1 1 1 1 0 0 0 1 1 0 0 1 1 0 0 1 0 1 0 1 0 1 0 0 0 0 0 0 FREQUENCY LEVEL BUFFER *Sound duration will be slightly longer than these times because each sound always completes a full cycle before stopping. 22 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers Sounder Operation When an alert sound or key sound is happening, the user cannot write to the sounder. The MAX7347/MAX7348/ MAX7349 do not acknowledge a write to the sounder I2C address. However, a read from the sounder will work correctly. An alert sound or key sound event terminates a current user-programmed event and clears the queue. If an alert sound or key sound event is currently being processed, then a new alert sound or key sound event will be put into the queue, replacing an existing queued alert sound or key sound event, if one exists. User access to the sounder is restored when the last alert sound or key sound event is completed. Note this means that the buffer bit (D0) for an alert sound or key sound command is effectively ignored. Applications Information Ghost-Key Elimination Ghost keys are a phenomenon inherent with key-switch matrices. When three switches located at the corners of a matrix rectangle are pressed simultaneously, the switch that is located at the last corner of the rectangle (the ghost key) also appears to be pressed. This occurs because the potentials at the two sides of the ghost-key switch are identical due to the other three connections-- the switch is electrically shorted by the combination of the other three switches (Figure 10). Because the key appears to be pressed electrically, it is impossible for software to detect which of the four keys is the ghost key. The MAX7347/MAX7348/MAX7349 employ a proprietary scheme that detects any three-key combination that generates a fourth ghost key, and does not report any of these four keys as being pressed. This means that although ghost keys are never reported, many combinations of three keys are effectively ignored when pressed at the same time. Applications requiring three key combinations (such as MAX7347/MAX7348/MAX7349 Shutdown The MAX7347/MAX7348/MAX7349 are put into shutdown mode by clearing bit D7 in the configuration register (Table 12). In shutdown, the key-scan controller and sounder controller are both disabled, and the MAX7347/MAX7348/MAX7349 draw minimal current. No additional supply current is drawn if any keys are pressed. All switch matrix current sources are turned off, and row outputs ROW0 to ROW7 and column outputs COL0 to COL7 become high impedance. The alert input status may still be read in shutdown, and an alert event can still cause an interrupt request if this feature is enabled (Table 12). This means that alert can be used for C wakeup while the system sleeps drawing minimum current. Outputs configured as GPOs (COL2/PORT2 to COL2/PORT7 and INT) may still be controlled in shutdown and their output states can be changed under software control at any time. The sounder output may not be changed in shutdown, even if it is effectively being used as a logic output. Writes to the sounder during shutdown are ignored, and the sounder FIFO is cleared on entering shutdown. However, the sounder retains its output logic state for the duration of shutdown, and so can be set low or high as desired by writing 0x00 or 0x02, respectively, to the sounder register (Table 12) before entering shutdown. The MAX7347/MAX7348/MAX7349 may be taken out of shutdown mode and put into operating mode by setting bit D7 in the configuration register (Table 12). The keyscan and sounder controller FIFOs are cleared, and key monitoring starts. Note that rewriting the configuration register with bit D7 high when bit D7 was already high does not clear the FIFOs; the FIFOs are only cleared when the MAX7347/MAX7348/MAX7349 are actually coming out of shutdown. Power-Supply Considerations The MAX7347/MAX7348/MAX7349 operate with a 2.4V to 3.6V power-supply voltage. Bypass the power supply to GND with a 0.047F or higher ceramic capacitor as close to the device as possible. Switch On-Resistance The MAX7347/MAX7348/MAX7349 are designed to be insensitive to resistance either in the key switches or the switch routing to and from the appropriate COLx and ROWx up to 5k. These controllers are therefore compatible with low-cost membrane and conductive carbon switches. ______________________________________________________________________________________ 23 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 REGULAR KEY-PRESS EVENT GHOST-KEY EVENT EXAMPLES OF VALID THREE-KEY COMBINATIONS KEY-SWITCH MATRIX KEY-SWITCH MATRIX KEY-SWITCH MATRIX Figure 10. Ghost-Key Phenomenon Figure 11. Valid Three-Key Combinations VCC 50k BIAS SHDN OUT50k SHUTDOWN 10k 16 IN+ 10k OUT+ 0.22F SOUNDER OUTPUT 2.61k 21.5k 32.4k IN- MAX4366 220pF 68nF 22nF 21.5k Figure 12. Third-Order Chebyshev Lowpass Filter and Output Stage Audio Transducers The sounder output is designed to drive a standard, lowcost piezo transducer directly without further buffering. Piezo transducers appear as a capacitive load of typically 10nF. If a resistive or inductive sounder is used, such as a small loudspeaker, fit a coupling capacitor between the sounder output and the transducer. For example, if a 32 speaker is used, connect the positive side of a 22F electrolytic capacitor to the sounder output, the negative side of the capacitor to one end of the speaker, and the other end of the speaker to GND. The sounder output can also drive a power amplifier for higher sound levels. In this case, it is usually desirable to include a lowpass filter before the speaker to convert the square-wave tones to something closer to a sinusoid. The recommended cutoff frequency of this filter is around 3kHz. An example circuit is shown in Figure 12, which uses the uncommitted op amp of the MAX4366 bridge power amplifier to implement a third-order Chebyshev lowpass filter. Chip Information TRANSISTOR COUNT: 51,987 PROCESS: BiCMOS 24 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers Typical Application Circuit MAX7347/MAX7348/MAX7349 KEY 0 3.3V 3.3V 3.3V KEY 8 KEY 16 V+ COL2/PORT2 COL1 KEY 1 KEY 9 KEY 17 MAX7348 COL0 COL3/PORT3 ROW0 COL4/PORT4 ROW1 5V AD0 ROW2 ROW3 KEY 4 SCL SDA INT SCL SDA INT SOUNDER GND GND ROW4 ROW5 KEY 5 ROW6 ROW7 KEY 6 KEY 14 KEY 22 KEY 13 KEY 21 KEY 12 KEY 20 KEY 3 KEY 11 KEY 19 KEY 2 KEY 10 KEY 18 V+ PIEZOELECTRIC TRANSDUCER KEY 7 KEY 15 KEY 23 ______________________________________________________________________________________ 25 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Pin Configurations TOP VIEW ROW0 1 ROW1 2 ROW2 3 ROW3 4 ROW4 5 ROW5 6 ROW6 7 ROW7 8 16 V+ 15 INT 14 SCL TOP VIEW COL7/PORT7 1 ROW0 2 ROW1 3 ROW2 4 ROW3 5 COL3/PORT3 6 COL4/PORT4 7 ROW4 8 ROW5 9 ROW6 10 24 ALERT 23 V+ 22 INT 21 SCL MAX7347 13 SDA 12 GND 11 COL0 10 COL1 9 COL2/PORT2 MAX7349 20 SDA 19 AD0 18 GND 17 SOUNDER 16 COL0 15 COL1 14 COL2/PORT2 13 COL5/PORT5 QSOP TOP VIEW ROW0 1 ROW1 2 ROW2 3 ROW3 4 COL3/PORT3 5 COL4/PORT4 6 ROW4 7 ROW5 8 ROW6 9 ROW7 10 20 V+ 19 INT 18 SCL 17 SDA ROW7 11 COL6/PORT6 12 QSOP/SO MAX7348 16 AD0 15 GND 14 SOUNDER 13 COL0 12 COL1 11 COL2/PORT2 QSOP 26 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers Package Information (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information, go to www.maxim-ic.com/packages.) QSOP.EPS MAX7347/MAX7348/MAX7349 PACKAGE OUTLINE, QSOP .150", .025" LEAD PITCH 21-0055 E 1 1 _______________________________________________________________________________________ 27 ______________________________________________________________________________________ 2-Wire Interfaced Low-EMI Key Switch and Sounder Controllers MAX7347/MAX7348/MAX7349 Package Information (continued) (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information, go to www.maxim-ic.com/packages.) SOICW.EPS INCHES N MILLIMETERS MIN 2.35 0.10 0.35 0.23 MAX 2.65 0.30 0.49 0.32 E H DIM A A1 B C e E H L MAX MIN 0.104 0.093 0.012 0.004 0.019 0.014 0.013 0.009 0.050 0.299 0.291 0.394 0.419 0.050 0.016 1.27 7.40 7.60 10.00 10.65 0.40 1.27 1 VARIATIONS: INCHES MILLIMETERS MIN 10.10 11.35 12.60 15.20 17.70 MAX 10.50 11.75 13.00 15.60 18.10 N MS013 16 AA 18 AB 20 AC 24 AD 28 AE TOP VIEW D DIM D D D D D MIN 0.398 0.447 0.496 0.598 0.697 MAX 0.413 0.463 0.512 0.614 0.713 A e B A1 C 0-8 L FRONT VIEW SIDE VIEW PROPRIETARY INFORMATION TITLE: PACKAGE OUTLINE, .300" SOIC APPROVAL DOCUMENT CONTROL NO. REV. 21-0042 B 1 1 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. 28 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 (c) 2005 Maxim Integrated Products Printed USA is a registered trademark of Maxim Integrated Products, Inc. |
Price & Availability of MAX7347 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |