    PS-DA0250-02 PS-DA0250-02S

Power Systems GmbH Co.KG
Part No. PS-DA0250-02 PS-DA0250-02S
OCR Text ... use plastic screw in case of a non-insulating mounting base! Components No. 1 2 3 Part Description PCB connector CN1 connector CN2 Qty. ...Dimming (CN1-4). When 'Ext.PWM' (CN1-4) is used 'Vrmt' (CN1-3) should not be connected. The inverter...
Description DC-AC INVERTER UNIT 4 W SINGLE OUTPUTS

File Size 77.46K  /  2 Page

View it Online

Download Datasheet





    CXA-0286

http://
Power Systems GmbH Co.KG
Part No. CXA-0286
OCR Text ... Operation of unit Operation Non operation Non operation Iin A V CN1-1.2 Vin CN1-3.4 GND CN1-5 Vbr CN1-6 NC CN1-7 Vrmt Q T1 1 2 3 4 5 1 2 3 4 9 T2 9 6 C CN2-1 Vhigh1 CN2-2 Vlow1 RL Iout1 RL A ~ 6 C ...
Description DC-AC INVERTER UNIT 15W THREE OUTPUTS WITH DIMMING FUNCTION

File Size 154.63K  /  2 Page

View it Online

Download Datasheet

    CXA-0308

http://
Power Systems GmbH Co.KG
Part No. CXA-0308
OCR Text ... Operation of unit Operation Non operation SW3 a V T1 SW1 CN1-5 Q6 CN2-2 C10 C25 RL2 A ~ RL1 CL2 CL1 b SW2 a b Operation of unit Voltage dimming Vbr=0~2.5V Variable resistance dimming VR=0~50k Vbr 0~2.5...
Description DC-AC INVERTER UNIT 8W DUAL OUTPUTS WITH DIMMING FUNCTION

File Size 166.52K  /  2 Page

View it Online

Download Datasheet

    CXA-0315

http://
Power Systems GmbH Co.KG
Part No. CXA-0315
OCR Text ... Operation of unit Operation Non operation Non operation Operation of shutdown Operation Non operation 6 C19 CN2-2 Vhigh2 CN4-2 Vlow2 RL2 CN1-5 Vbr SW3 A ~ Iout2 Vbr 0 / 5V CN1-6 NC CN1-7 Vrmt 2 3 4 1 5 T2 8,9...
Description DC-AC INVERTER UNIT 21W QUAD OUTPUTS WITH DIMMING FUNCTION

File Size 166.43K  /  2 Page

View it Online

Download Datasheet

    CXA-0317

http://
Power Systems GmbH Co.KG
Part No. CXA-0317
OCR Text ...V Open 2.5-14.4V Unit Operation Non Active Active 1000:1 V Power Systems - The Power Solution Web: Emai: www.Power-Systems.de Info@Power-Systems.de Page ( 3 / 3 ) All specification are subject to change without notice. Address: Do...
Description DC-AC INVERTER UNIT 18W QUAD OUTPUTS WITH DIMMING FUNCTION

File Size 126.74K  /  3 Page

View it Online

Download Datasheet

    CXA-0320

http://
Power Systems GmbH Co.KG
Part No. CXA-0320
OCR Text ... Operation of unit Operation Non operation Non operation Vin 10.8~13.2V A a b OPEN a V b SW2 Io1 A ~ Operation of unit Voltage Dimming Vbr=0~2.5V Valiable resistance Dimming Rbr=0~50k Operation of warning signal O...
Description DC-AC INVERTER UNIT 5W DUAL OUTPUTS WITH DIMMING FUNCTION

File Size 98.56K  /  2 Page

View it Online

Download Datasheet

    CXA-0321

Power Systems GmbH Co.KG
http://
Part No. CXA-0321
OCR Text ... Operation of unit Operation Non operation Non operation CN1-1 CN1-2 CN3-1 CN2-1 T1 CN1-5 C10 C25 Q05 CN1-6 (Q06) Io1 CN2CN33 3 RL1 a b Open CN1-3 CN1-4 Vrmt 0/5V a V RL2 A ~ Io2 A ~ b SW1 SW2~4 Open Close Operat...
Description DC-AC INVERTER UNIT 5W DUAL OUTPUTS WITH DIMMING FUNCTION

File Size 117.86K  /  2 Page

View it Online

Download Datasheet

    CXA-0326

Power Systems GmbH Co.KG
http://
Part No. CXA-0326
OCR Text ... Operation of unit Operation Non operation Non operation CN1-3 CN1-4 Vrmt 0/5V a V CN1-5 b Open b SW1 Q04 CN1-6 (Q05) Vbr 0~2.5V V CN1-7 CN1-8 V Vst CN2-3 CN3-3 Power Systems - The Power Solution Web: Email: ...
Description DC-AC INVERTER UNIT 5W DUAL OUTPUTS WITH DIMMING FUNCTION

File Size 33.97K  /  2 Page

View it Online

Download Datasheet

    CXA-0349

http://
Power Systems GmbH Co.KG
Part No. CXA-0349
OCR Text ...pen Operation of unit Operation Non operation Non operation Note4. SW3~6(Open/Close) Operation is as following; SW3~5 Open Close Operation of warning signal Operation (5V output) Non operation (0V output) Note 5 : In the circui...
Description DC-AC INVERTER UNIT QUAD OUTPUTS WITH DIMMING FUNCTION

File Size 219.07K  /  3 Page

View it Online

Download Datasheet

    CXA-0359 CXA-0359R

Power Systems GmbH Co.KG
http://
Part No. CXA-0359 CXA-0359R
OCR Text ... use plastic screw in case of a non-insulating mounting base! Unit : mm Weight :23 (g) typ. Components No. 1 2 3 Part Description P...DIMMING FUNCTION) Input side CN1: Pin No. Symbols Ratings Vin 11.4 ~ 12.6 Vdc CN 1-1+2 GND CN 1-3+4...
Description DC-AC INVERTER UNIT 8 W DUAL OUTPUTS WITH DIMMING FUNCTION

File Size 145.30K  /  3 Page

View it Online

Download Datasheet

For non-dimming connector Found Datasheets File :: 280    Search Time::1.25ms    
Page :: | 1 | 2 | 3 | 4 | 5 | 6 | 7 | <8> | 9 | 10 | 11 | 12 | 13 | 14 | 15 |   

▲Up To Search▲

 




Price and Availability




 
Price & Availability of non-dimming connector

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X
6.3923709392548